Computational analyses of a pressurized metered dose inhaler and a new drug-aerosol targeting methodology.

The popular pressurized metered dose inhaler (pMDI), especially for asthma treatment, has undergone various changes in terms of propellant use and valve design. Most significant are the choice of hydrofluoroalkane-134a (HFA-134a) as a new propellant (rather than chlorofluorocarbon, CFC), a smaller exit nozzle diameter and attachment of a spacer in order to reduce ultimately droplet size and spray inhalation speed, both contributing to higher deposition efficiencies and hence better asthma therapy. Although asthma medicine is rather inexpensive, the specter of systemic side effects triggered by inefficient pMDI performance and the increasing use of such devices as well as new targeted drug-aerosol delivery for various lung and other diseases make detailed performance analyses imperative. For the first time, experimentally validated computational fluid-particle dynamics technique has been applied to simulate airflow, droplet spray transport and aerosol deposition in a pMDI attached to a human upper airway model, considering different device propellants, nozzle diameters, and spacer use. The results indicate that the use of HFA (replacing CFC), smaller valve orifices (0.25 mm instead of 0.5 mm) and spacers (ID = 4.2 cm) leads to best performance mainly because of smaller droplets generated, which penetrate more readily into the bronchial airways. Experimentally validated computer simulations predict that 46.6% of the inhaled droplets may reach the lung for an HFA-pMDI and 23.2% for a CFC-pMDI, both with a nozzle-exit diameter of 0.25 mm. Commonly used inhalers are nondirectional, and at best only regional drug-aerosol deposition can be achieved. However, when inhaling expensive and aggressive medicine, or critical lung areas have to be reached, locally targeted drug-aerosol delivery is imperative. For that reason the underlying principle of a future line of "smart inhalers" is introduced. Specifically, by generating a controlled air-particle stream, most of the inhaled drug aerosols reach predetermined lung sites, which are associated with specific diseases and/or treatments. Using the same human upper airway model, experimentally confirmed computer predictions of controlled particle transport from mouth to generation 3 are provided.

[1]  Bean T. Chen,et al.  Particle Deposition in a Cast of Human Oral Airways , 1999 .

[2]  A. P. Watkins,et al.  An experimental investigation of the spray issued from a pMDI using laser diagnostic techniques. , 1997, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[3]  C. Leach,et al.  Improved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone. , 1998, The European respiratory journal.

[4]  Xiangmin Jiao,et al.  Variational generation of prismatic boundary‐layer meshes for biomedical computing , 2009, International journal for numerical methods in engineering.

[5]  M. Hindle,et al.  Quantitative analysis and design of a spray aerosol inhaler. Part 1: effects of dilution air inlets and flow paths. , 2009, Journal of aerosol medicine and pulmonary drug delivery.

[6]  F. Tanner Liquid Jet Atomization and Droplet Breakup Modeling of Non-Evaporating Diesel Fuel Sprays , 1997 .

[7]  C Kleinstreuer,et al.  Targeted drug aerosol deposition analysis for a four-generation lung airway model with hemispherical tumors. , 2003, Journal of biomechanical engineering.

[8]  C Kleinstreuer,et al.  Targeted drug-aerosol delivery in the human respiratory system. , 2008, Annual review of biomedical engineering.

[9]  B. Gabrio,et al.  Advances in metered dose inhaler technology with the development of a chlorofluorocarbon-free drug delivery system. , 1999, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[10]  M. Hindle,et al.  Evaluation of the Respimat Soft Mist Inhaler using a concurrent CFD and in vitro approach. , 2009, Journal of aerosol medicine and pulmonary drug delivery.

[11]  R. Dhand Aerosol plumes: slow and steady wins the race. , 2005, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[12]  Y. Cheng,et al.  Respiratory deposition patterns of salbutamol pMDI with CFC and HFA-134a formulations in a human airway replica. , 2001, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[13]  Clement Kleinstreuer,et al.  Low-Reynolds-Number Turbulent Flows in Locally Constricted Conduits: A Comparison Study , 2003 .

[14]  William L. Roberts,et al.  A new methodology for targeting drug-aerosols in the human respiratory system , 2008 .

[15]  J. L. Gregg,et al.  The Variable Fluid-Property Problem in Free Convection , 1958, Journal of Fluids Engineering.

[16]  N. Khorsand,et al.  In Vitro Performance of Two Common Valved Holding Chambers with a Chlorofluorocarbon‐Free Beclomethasone Metered‐Dose Inhaler , 2003, Pharmacotherapy.

[17]  W. Finlay,et al.  In vitro effect of a holding chamber on the mouth-throat deposition of QVAR (hydrofluoroalkane-beclomethasone dipropionate). , 2002, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[18]  H. Hiroyasu,et al.  Fuel Droplet Size Distribution in Diesel Combustion Chamber , 1974 .

[19]  Frediano V. Bracco,et al.  LDV measurements of drop velocity in diesel-type sprays , 1984 .

[20]  J. F. Miller,et al.  THEORETICAL INVESTIGATION OF THE SPRAY FROM A PRESSURIZED METERED-DOSE INHALER , 1997 .

[21]  W. Finlay,et al.  Improved numerical simulation of aerosol deposition in an idealized mouth-throat , 2004 .

[22]  C. Kleinstreuer,et al.  Simulation and Analysis of High-Speed Droplet Spray Dynamics , 2007 .

[23]  Clement Kleinstreuer,et al.  Laminar-to-turbulent fluid-particle flows in a human airway model , 2003 .

[24]  E. Matida,et al.  Characterization of the spray velocities from a pressurized metered-dose inhaler. , 2009, Journal of aerosol medicine and pulmonary drug delivery.

[25]  Yung Sung Cheng,et al.  Aerosol Deposition in the Extrathoracic Region , 2003, Aerosol science and technology : the journal of the American Association for Aerosol Research.

[26]  D. Donnell Optimizing Drug Delivery to the Lung: Design of a CFC-Free Corticosteroid Metered-Dose Aerosol System , 2001, Drug development and industrial pharmacy.

[27]  Y. Cheng,et al.  Measurements of airway dimensions and calculation of mass transfer characteristics of the human oral passage. , 1997, Journal of biomechanical engineering.

[28]  Gerard M. Faeth,et al.  CURRENT STATUS OF DROPLET AND LIQUID COMBUSTION , 1977 .

[29]  H. Bokuniewicz,et al.  Trace metal levels in uncontaminated groundwater of a coastal watershed: importance of colloidal forms. , 2002, Environmental science & technology.

[30]  C. Dunbar ATOMIZAT10N MECHANISMS OF THE PRESSURIZED METERED DOSE INHALER , 1997 .

[31]  W. De Backer,et al.  Study of the Variability in Upper and Lower Airway Morphology in Sprague–Dawley Rats Using Modern Micro‐CT Scan‐Based Segmentation Techniques , 2009, Anatomical record.

[32]  M. Hindle,et al.  Effects of generation time on spray aerosol transport and deposition in models of the mouth-throat geometry. , 2009, Journal of aerosol medicine and pulmonary drug delivery.

[33]  Clement Kleinstreuer,et al.  Comparison of micro- and nano-size particle depositions in a human upper airway model , 2005 .