Control Algorithms for a Fault-Tolerant PMSM Drive

This paper proposes control algorithms for a fault-tolerant permanent-magnet synchronous motor (PMSM) drive. In order to improve the reliability of the drive, an algorithm for achieving a sensorless control that operates properly also in fault mode is proposed. Furthermore, it is shown how a closed-loop field-weakening controller needs to be modified in order to operate properly in fault mode. Automotive applications are in mind and the algorithms presented are verified with experimental results using an in-wheel PMSM. With the proposed modifications, the reliability of the drive can be improved.

[1]  Edison Roberto Cabral da Silva,et al.  Fault-tolerant voltage-fed PWM inverter AC motor drive systems , 2004, IEEE Transactions on Industrial Electronics.

[2]  N. Bianchi,et al.  Innovative Remedial Strategies for Inverter Faults in IPM Synchronous Motor Drives , 2002, IEEE Power Engineering Review.

[3]  O. Carlson,et al.  Post-fault operation of fault-tolerant inverters for PMSM drives , 2005, 2005 European Conference on Power Electronics and Applications.

[4]  Lennart Harnefors,et al.  Torque-maximizing field-weakening control: design, analysis, and parameter selection , 2001, IEEE Trans. Ind. Electron..

[5]  Mehrdad Ehsani,et al.  Effect of Motor Short Circuit on EV and HEV Traction Systems , 2000 .

[6]  Bimal K. Bose,et al.  Power Electronics and Variable Frequency Drives , 1996 .

[7]  O. Carlson,et al.  Sensorless control of PMSM drives for hybrid electric vehicles , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[8]  K. H. Hussein,et al.  IPMs solving major reliability issues in automotive applications [intelligent power module] , 2004, 2004 Proceedings of the 16th International Symposium on Power Semiconductor Devices and ICs.

[9]  Thomas M. Jahns,et al.  Interior Permanent-Magnet Synchronous Motors for Adjustable-Speed Drives , 1986, IEEE Transactions on Industry Applications.

[10]  N. Bianchi,et al.  Fault– Tolerant PM Motors in Automotive Applications , 2005, 2005 IEEE Vehicle Power and Propulsion Conference.

[11]  Hans-Peter Nee,et al.  A general algorithm for speed and position estimation of AC motors , 2000, IEEE Trans. Ind. Electron..

[12]  T.A. Lipo,et al.  Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations , 2003, IEEE Transactions on Power Electronics.

[13]  Oskar Wallmark,et al.  Sensorless Control of Salient PMSM Drives in the Transition Region , 2006, IEEE Transactions on Industrial Electronics.

[14]  Silverio Bolognani,et al.  Experimental fault-tolerant control of a PMSM drive , 1998, IECON '98. Proceedings of the 24th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.98CH36200).

[15]  André M. S. Mendes,et al.  Fault-Tolerant Operating Strategies Applied to Three-Phase Induction-Motor Drives , 2006, IEEE Transactions on Industrial Electronics.

[16]  Thomas A. Lipo,et al.  A strategy to isolate the switching device fault of a current regulated motor drive , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[17]  Paul P. Acarnley,et al.  Review of position-sensorless operation of brushless permanent-magnet machines , 2006, IEEE Transactions on Industrial Electronics.