Inclusion of geometric uncertainties in treatment plan evaluation.

PURPOSE To correctly evaluate realistic treatment plans in terms of absorbed dose to the clinical target volume (CTV), equivalent uniform dose (EUD), and tumor control probability (TCP) in the presence of execution (random) and preparation (systematic) geometric errors. MATERIALS AND METHODS The dose matrix is blurred with all execution errors to estimate the total dose distribution of all fractions. To include preparation errors, the CTV is randomly displaced (and optionally rotated) many times with respect to its planned position while computing the dose, EUD, and TCP for the CTV using the blurred dose matrix. Probability distributions of these parameters are computed by combining the results with the probability of each particular preparation error. We verified the method by comparing it with an analytic solution. Next, idealized and realistic prostate plans were tested with varying margins and varying execution and preparation error levels. RESULTS Probability levels for the minimum dose, computed with the new method, are within 1% of the analytic solution. The impact of rotations depends strongly on the CTV shape. A margin of 10 mm between the CTV and planning target volume is adequate for three-field prostate treatments given the accuracy level in our department; i.e., the TCP in a population of patients, TCP(pop), is reduced by less than 1% due to geometric errors. When reducing the margin to 6 mm, the dose must be increased from 80 to 87 Gy to maintain the same TCP(pop). Only in regions with a high-dose gradient does such a margin reduction lead to a decrease in normal tissue dose for the same TCP(pop). Based on a rough correspondence of 84% minimum dose with 98% EUD, a margin recipe was defined. To give 90% of patients at least 98% EUD, the planning target volume margin must be approximately 2.5 Sigma + 0.7 sigma - 3 mm, where Sigma and sigma are the combined standard deviations of the preparation and execution errors. This recipe corresponds accurately with 1% TCP(pop) loss for prostate plans with clinically reasonable values of Sigma and sigma. CONCLUSION The new method computes in a few minutes the influence of geometric errors on the statistics of target dose and TCP(pop) in clinical treatment plans. Too small margins lead to a significant loss of TCP(pop) that is difficult to compensate for by dose escalation.

[1]  J. Leong,et al.  Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation. , 1987, Physics in medicine and biology.

[2]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[3]  I. Kalet,et al.  Three dimensional planning target volumes: a model and a software tool. , 1995, International Journal of Radiation Oncology, Biology, Physics.

[4]  M van Herk,et al.  A general methodology for three-dimensional analysis of variation in target volume delineation. , 1999, Medical physics.

[5]  K L Lam,et al.  Automated localization of the prostate at the time of treatment using implanted radiopaque markers: technical feasibility. , 1995, International journal of radiation oncology, biology, physics.

[6]  M van Herk,et al.  Computerized design of target margins for treatment uncertainties in conformal radiotherapy. , 1999, International journal of radiation oncology, biology, physics.

[7]  P J Keall,et al.  A method to predict the effect of organ motion and set-up variations on treatment plans. , 1999, Australasian physical & engineering sciences in medicine.

[8]  D. Yan,et al.  A model to accumulate fractionated dose in a deforming organ. , 1999, International journal of radiation oncology, biology, physics.

[9]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[10]  A. Nahum,et al.  Tumour control probability modelling: Basic principles and applications in treatment planning. , 2001 .

[11]  R Mohan,et al.  Dose-volume histograms. , 1991, International journal of radiation oncology, biology, physics.

[12]  D Verellen,et al.  Electronic portal imaging with on-line correction of setup error in thoracic irradiation: clinical evaluation. , 1998, International journal of radiation oncology, biology, physics.

[13]  M van Herk,et al.  Target margins for random geometrical treatment uncertainties in conformal radiotherapy. , 1996, Medical physics.

[14]  J. Battista,et al.  Considerations for the implementation of target volume protocols in radiation therapy. , 2001, International Journal of Radiation Oncology, Biology, Physics.

[15]  D. Gladstone,et al.  A numerical simulation of organ motion and daily setup uncertainties: implications for radiation therapy. , 1997, International journal of radiation oncology, biology, physics.

[16]  J Bijhold,et al.  Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  M van Herk,et al.  The width of margins in radiotherapy treatment plans. , 2000, Physics in medicine and biology.

[18]  D Yan,et al.  An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer. , 2000, International journal of radiation oncology, biology, physics.

[19]  M van Herk,et al.  A verification procedure to improve patient set-up accuracy using portal images. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[20]  M van Herk,et al.  Definition of the prostate in CT and MRI: a multi-observer study. , 1999, International journal of radiation oncology, biology, physics.

[21]  S. Zavgorodni Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy. , 2000, Medical physics.

[22]  S Webb,et al.  A model for calculating tumour control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic cell density. , 1993, Physics in medicine and biology.

[23]  A new method for optimum dose distribution determination taking tumour mobility into account. , 1996, Physics in medicine and biology.

[24]  Joos V Lebesque,et al.  Margins for translational and rotational uncertainties: a probability-based approach. , 2002, International journal of radiation oncology, biology, physics.

[25]  M Engelsman,et al.  The effect of breathing and set-up errors on the cumulative dose to a lung tumor. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[26]  A. Niemierko,et al.  Random sampling for evaluating treatment plans. , 1990, Medical physics.

[27]  A. Niemierko Reporting and analyzing dose distributions: a concept of equivalent uniform dose. , 1997, Medical physics.

[28]  M van Herk,et al.  3-D portal image analysis in clinical practice: an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients. , 2000, International journal of radiation oncology, biology, physics.

[29]  J. Lebesque,et al.  The simultaneous boost technique: the concept of relative normalized total dose. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[30]  A. Nahum,et al.  The delta-TCP concept: a clinically useful measure of tumor control probability. , 1999, International journal of radiation oncology, biology, physics.

[31]  R Mohan,et al.  A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans. , 1996, International journal of radiation oncology, biology, physics.

[32]  J C Stroom,et al.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. , 1999, International journal of radiation oncology, biology, physics.

[33]  R I MacKay,et al.  Animation and radiobiological analysis of 3D motion in conformal radiotherapy. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[34]  J A Antolak,et al.  Planning target volumes for radiotherapy: how much margin is needed? , 1999, International journal of radiation oncology, biology, physics.

[35]  M van Herk,et al.  Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. , 1995, International journal of radiation oncology, biology, physics.

[36]  M Goitein,et al.  Strategies for treating possible tumor extension: some theoretical considerations. , 1985, International journal of radiation oncology, biology, physics.

[37]  A. Brahme,et al.  Optimal dose distribution for eradication of heterogeneous tumours. , 1987, Acta oncologica.

[38]  L. Marks Radiosurgery dose distributions: theoretical impact of inhomogeneities on lesion control. , 1994, Acta neurochirurgica. Supplement.

[39]  R Calandrino,et al.  Variations of tumor control and rectum complication probabilities due to random set-up errors during conformal radiation therapy of prostate cancer. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[40]  A Bel,et al.  High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging. , 1996, International journal of radiation oncology, biology, physics.

[41]  M. Goitein,et al.  Accuracy of radiation field alignment in clinical practice. , 1985, International journal of radiation oncology, biology, physics.

[42]  W A Beckham,et al.  Evaluation of the validity of a convolution method for incorporating tumour movement and set-up variations into the radiotherapy treatment planning system. , 2000, Physics in medicine and biology.

[43]  D. Johnston,et al.  Detailed mapping of prostate carcinoma foci , 2000, Cancer.

[44]  C. Ling,et al.  Analysis of biopsy outcome after three-dimensional conformal radiation therapy of prostate cancer using dose-distribution variables and tumor control probability models. , 2000, International journal of radiation oncology, biology, physics.