Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

BACKGROUND Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. MATERIALS AND METHODS Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. RESULTS The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. CONCLUSIONS In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

[1]  R. Bergenstal,et al.  The role of self-monitoring of blood glucose in the care of people with diabetes: report of a global consensus conference. , 2005, The American journal of medicine.

[2]  Jennifer Y. Liu,et al.  Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes registry. , 2001, The American journal of medicine.

[3]  Andreas Pfützner,et al.  Accuracy evaluation of five blood glucose monitoring systems obtained from the pharmacy: a European multicenter study with 453 subjects. , 2012, Diabetes technology & therapeutics.

[4]  B H Ginsberg,et al.  A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. , 2000, Diabetes care.

[5]  Andreas Pfützner,et al.  Clinical assessment of the accuracy of blood glucose measurement devices , 2012, Current medical research and opinion.

[6]  E. Ipp,et al.  Accuracy of Plasma Glucose Measurements in the Hypoglycemic Range , 1994, Diabetes Care.

[7]  P. Twomey,et al.  Plasma glucose measurement with the Yellow Springs Glucose 2300 STAT and the Olympus AU640 , 2004, Journal of Clinical Pathology.

[8]  Christina Schmid,et al.  Lot-to-Lot Variability of Test Strips and Accuracy Assessment of Systems for Self-Monitoring of Blood Glucose according to ISO 15197 , 2012, Journal of diabetes science and technology.

[9]  R. Bamberg,et al.  Effect of Adverse Storage Conditions on Performance of Glucometer Test Strips , 2005, American Society for Clinical Laboratory Science.

[10]  A. Philis-Tsimikas,et al.  Precision, Accuracy, and User Acceptance of the OneTouch SelectSimple Blood Glucose Monitoring System , 2011, Journal of diabetes science and technology.

[11]  Guido Freckmann,et al.  System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197. , 2010, Diabetes technology & therapeutics.

[12]  C. Higgins Capillary blood gases: to arterialize or not. , 2008, MLO: medical laboratory observer.

[13]  Christopher G Parkin,et al.  Performance Variability of Seven Commonly Used Self-Monitoring of Blood Glucose Systems: Clinical Considerations for Patients and Providers , 2013, Journal of diabetes science and technology.

[14]  G. H. Thorpe,et al.  Assessing the quality of publications evaluating the accuracy of blood glucose monitoring systems. , 2013, Diabetes technology & therapeutics.

[15]  S. Garg,et al.  Rising epidemic of diabetes and hypertension in Asia. , 2012, Diabetes technology & therapeutics.

[16]  Sverre Sandberg,et al.  Between-lot variation in external quality assessment of glucose: clinical importance and effect on participant performance evaluation. , 2005, Clinical chemistry.

[17]  Ming-Hsun Wu,et al.  Accuracy and precision evaluation of seven self-monitoring blood glucose systems. , 2011, Diabetes technology & therapeutics.

[18]  A. Karter,et al.  Current evidence regarding the value of self-monitored blood glucose testing. , 2005, The American journal of medicine.

[19]  Gunn B B Kristensen,et al.  Standardized evaluation of nine instruments for self-monitoring of blood glucose. , 2008, Diabetes technology & therapeutics.