Neuromuscular Interfacing: Establishing an EMG-Driven Model for the Human Elbow Joint

Assistive devices aim to mitigate the effects of physical disability by aiding users to move their limbs or by rehabilitating through therapy. These devices are commonly embodied by robotic or exoskeletal systems that are still in development and use the electromyographic (EMG) signal to determine user intent. Not much focus has been placed on developing a neuromuscular interface (NI) that solely relies on the EMG signal, and does not require modifications to the end user's state to enhance the signal (such as adding weights). This paper presents the development of a flexible, physiological model for the elbow joint that is leading toward the implementation of an NI, which predicts joint motion from EMG signals for both able-bodied and less-abled users. The approach uses musculotendon models to determine muscle contraction forces, a proposed musculoskeletal model to determine total joint torque, and a kinematic model to determine joint rotational kinematics. After a sensitivity analysis and tuning using genetic algorithms, subject trials yielded an average root-mean-square error of 6.53° and 22.4° for a single cycle and random cycles of movement of the elbow joint, respectively. This helps us to validate the elbow model and paves the way toward the development of an NI.

[1]  Toshio Fukuda,et al.  An exoskeletal robot for human shoulder joint motion assist , 2003 .

[2]  Hugh Herr,et al.  Exoskeletons and orthoses: classification, design challenges and future directions , 2009, Journal of NeuroEngineering and Rehabilitation.

[3]  David G Lloyd,et al.  Neuromusculoskeletal modeling: estimation of muscle forces and joint moments and movements from measurements of neural command. , 2004, Journal of applied biomechanics.

[4]  C. R. Worthington,et al.  Muscle contraction: viscous-like frictional forces and the impulsive model. , 2001, International journal of biological macromolecules.

[5]  Arthur F T Mak,et al.  Feasibility of using EMG driven neuromusculoskeletal model for prediction of dynamic movement of the elbow. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[6]  Dinant A. Kistemaker,et al.  A model of open-loop control of equilibrium position and stiffness of the human elbow joint , 2007, Biological Cybernetics.

[7]  Walter Herzog,et al.  Model-based estimation of muscle forces exerted during movements. , 2007, Clinical biomechanics.

[8]  S.G. Meek,et al.  Fatigue compensation of the electromyographic signal for prosthetic control and force estimation , 1993, IEEE Transactions on Biomedical Engineering.

[9]  Toshio Fukuda,et al.  Neuro-fuzzy control of a robotic exoskeleton with EMG signals , 2004, IEEE Transactions on Fuzzy Systems.

[10]  Blake Hannaford,et al.  Hill-Based Model as a Myoprocessor for a Neural Controlled Powered Exoskeleton Arm - Parameters Optimization , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[11]  Michael Goldfarb,et al.  Volitional Control of a Prosthetic Knee Using Surface Electromyography , 2011, IEEE Transactions on Biomedical Engineering.

[12]  Alain Martin,et al.  Theoretical and experimental behaviour of the muscle viscosity coefficient during maximal concentric actions , 2004, European Journal of Applied Physiology and Occupational Physiology.

[13]  Jianda Han,et al.  A Novel Motion Estimate Method of Human Joint with EMG-Driven Model , 2011, 2011 5th International Conference on Bioinformatics and Biomedical Engineering.

[14]  Daniel P. Ferris,et al.  A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition , 2009, Journal of NeuroEngineering and Rehabilitation.

[15]  Miloslav Vilimek Musculotendon forces derived by different muscle models. , 2007, Acta of bioengineering and biomechanics.

[16]  J. Cram,et al.  Introduction to Surface Electromyography , 1998 .

[17]  Anish Sebastian,et al.  Adaptive multi sensor based nonlinear identification of skeletal muscle force , 2010 .

[18]  Sybert H. Stroeve,et al.  Impedance characteristics of a neuromusculoskeletal model of the human arm I. Posture control , 1999, Biological Cybernetics.

[19]  K. Ito,et al.  Discrimination of intended movements based on nonstationary EMG for a prosthetic hand control , 2008, 2008 3rd International Symposium on Communications, Control and Signal Processing.

[20]  Jacob Rosen,et al.  Performances of Hill-Type and Neural Network Muscle Models - Toward a Myosignal-Based Exoskeleton , 1999, Comput. Biomed. Res..

[21]  Panagiotis K. Artemiadis,et al.  EMG-based teleoperation of a robot arm using low-dimensional representation , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[22]  Qi Shao,et al.  An EMG-driven model to estimate muscle forces and joint moments in stroke patients , 2009, Comput. Biol. Medicine.

[23]  Massimo Sartori,et al.  A stiff tendon neuromusculoskeletal model of the knee , 2009, 2009 IEEE Workshop on Advanced Robotics and its Social Impacts.

[24]  C. Scovil,et al.  Sensitivity of a Hill-based muscle model to perturbations in model parameters. , 2006, Journal of biomechanics.

[25]  Hartmut Geyer,et al.  Control of a Powered Ankle–Foot Prosthesis Based on a Neuromuscular Model , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[26]  R. Enoka,et al.  Unraveling the neurophysiology of muscle fatigue. , 2011, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[27]  R. M. Glaser,et al.  Improving the efficacy of electrical stimulation-induced leg cycle ergometry: an analysis based on a dynamic musculoskeletal model , 1993 .

[28]  J.C. Perry,et al.  Upper-Limb Powered Exoskeleton Design , 2007, IEEE/ASME Transactions on Mechatronics.

[29]  Alan Smith,et al.  Myoelectric control techniques for a rehabilitation robot , 2011 .

[30]  Mikhail Kuznetsov,et al.  Filtering the surface EMG signal: Movement artifact and baseline noise contamination. , 2010, Journal of biomechanics.

[31]  R. Kirsch,et al.  EMG-based prediction of shoulder and elbow kinematics in able-bodied and spinal cord injured individuals. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[32]  F Goubel,et al.  Viscous properties of human muscle during contraction. , 1999, Journal of biomechanics.

[33]  Yoshiyuki Sankai,et al.  Development of single leg version of HAL for hemiplegia , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.