Facial convective heat exchange coefficients in cold and windy environments estimated from human experiments

Facial heat exchange convection coefficients were estimated from experimental data in cold and windy ambient conditions applicable to wind chill calculations. Measured facial temperature datasets, that were made available to this study, originated from 3 separate studies involving 18 male and 6 female subjects. Most of these data were for a −10°C ambient environment and wind speeds in the range of 0.2 to 6 m s−1. Additional single experiments were for −5°C, 0°C and 10°C environments and wind speeds in the same range. Convection coefficients were estimated for all these conditions by means of a numerical facial heat exchange model, applying properties of biological tissues and a typical facial diameter of 0.18 m. Estimation was performed by adjusting the guessed convection coefficients in the computed facial temperatures, while comparing them to measured data, to obtain a satisfactory fit (r2 > 0.98, in most cases). In one of the studies, heat flux meters were additionally used. Convection coefficients derived from these meters closely approached the estimated values for only the male subjects. They differed significantly, by about 50%, when compared to the estimated female subjects' data. Regression analysis was performed for just the −10°C ambient temperature, and the range of experimental wind speeds, due to the limited availability of data for other ambient temperatures. The regressed equation was assumed in the form of the equation underlying the “new” wind chill chart. Regressed convection coefficients, which closely duplicated the measured data, were consistently higher than those calculated by this equation, except for one single case. The estimated and currently used convection coefficients are shown to diverge exponentially from each other, as wind speed increases. This finding casts considerable doubts on the validity of the convection coefficients that are used in the computation of the "new" wind chill chart and their applicability to humans in cold and windy environments.

[1]  M Shacham,et al.  Meaningful wind chill indicators derived from heat transfer principles , 1995, International journal of biometeorology.

[2]  Maurice Bluestein,et al.  The New Wind Chill Equivalent Temperature Chart. , 2005 .

[3]  A. Guyton,et al.  Textbook of Medical Physiology , 1961 .

[4]  A. Ayata,et al.  Adult Head Circumferences and Centiles , 1997 .

[5]  A. Shitzer Transient Analysis of Cold Winds on Exposed Skin: Reflections on the Assessment of Wind Chill Equivalent Temperatures , 2008 .

[6]  Peter Tikuisis,et al.  Dynamic Model of Facial Cooling , 2002 .

[7]  Avraham Shitzer,et al.  Wind-chill-equivalent temperatures: regarding the impact due to the variability of the environmental convective heat transfer coefficient , 2006, International journal of biometeorology.

[8]  F. Kreith,et al.  Principles of heat transfer , 1962 .

[9]  G. Smith,et al.  Numerical Solution of Partial Differential Equations: Finite Difference Methods , 1978 .

[10]  P. Siple,et al.  Measurements of dry atmospheric cooling in subfreezing temperatures , 1945 .

[11]  Randall J. Osczevski,et al.  The Basis of Wind Chill , 1995 .

[12]  K. Kuklane,et al.  Comparison of Fiala model predictions with experimental data for extreme cold conditions , 2007 .

[13]  R L Knoblauch,et al.  OLDER PEDESTRIAN CHARACTERISTICS FOR USE IN HIGHWAY DESIGN. FINAL REPORT , 1995 .

[14]  Ingvar Holmér,et al.  Thermal responses to cold wind of thermoneutral and cooled subjects , 2000, European Journal of Applied Physiology.

[15]  M. Bluestein An evaluation of the wind chill factor: its development and applicability. , 1998, Journal of Biomechanical Engineering.

[16]  Peter Tikuisis,et al.  Prediction of facial cooling while walking in cold wind , 2007, Comput. Biol. Medicine.