Cryogenic Engineering Design of the ITER Superconducting Magnet Feeders

The ITER magnet system is to be operated at about 4.5 K. It has 31 feeders for high-current power supply, helium distribution and instrumentation cable routing. The feeders (except the smaller ones which are for instrumentation only) are 25 to 30 m long for about 40 tons. They have 3 main components: coil terminal box-cum-S-bend box (CTB-SBB), Cryostat feedthrough (CFT) and in-cryostat feeder (ICF). The CTB is the feeder component placed farthest from the coil (about 25 m away from the magnet center) and outside the bio-shield (the nuclear radiation restriction wall) so that it can be easily accessible in case the critical elements placed within it need maintenance: high-temperature superconducting current leads (HTSCL), large number of cryogenic control valves and pressure-release valves for quench protection. This paper explains the cryogenic design that considers these factors and main components.

[1]  Chen-yu Gung,et al.  Progress in Design, Analysis, and Manufacturing Studies of the ITER Feeders , 2012, IEEE Transactions on Applied Superconductivity.

[2]  Y. Ilyin,et al.  Key Components of the ITER Magnet Feeders , 2012, IEEE Transactions on Applied Superconductivity.

[3]  N Mitchell,et al.  Design of the ITER TF Magnet Feeder Systems , 2010, IEEE Transactions on Applied Superconductivity.

[4]  R. Gallix,et al.  Thermo-Mechanical Instrumentation of the ITER Magnet Structures , 2012, IEEE Transactions on Applied Superconductivity.

[5]  P. Libeyre,et al.  The ITER Magnets: Design and Construction Status , 2012, IEEE Transactions on Applied Superconductivity.

[6]  A. Perin,et al.  Specifications and Performances of Series Superfluid Helium Safety Relief Valves for the LHC , 2006 .

[7]  N Mitchell,et al.  Development of the Coil Terminal Boxes for the ITER Magnet Feeder Systems , 2010, IEEE Transactions on Applied Superconductivity.