Experimental investigations of frost release by hydrophilic surfaces

Frost formation occurs when water vapor in the surrounding air comes into contact with cold surfaces through heat and mass transfer. It is usually an undesirable phenomenon in most refrigeration and cryogenic systems. A few studies have shown that changing the surface energy, such as increasing the surface hydrophilicity or hydrophobicity, has significant effects on frost growth. In this paper, a kind of hydrophilic polymer paint is formulated to counteract frost deposition on cold surfaces. The coated surface can retard frost formation up to three hours under low plate temperatures (− 15.3°C) and high air humidity (72%). To test the antifrosting performance of the hydrophilic paint under more practical conditions, it is applied to a fin-and-tube heat exchanger and a domestic refrigerator at a coating thickness of 30 μm. Comparisons of frost deposition, pressure drops, and outlet temperatures are made between uncoated and coated heat exchangers. Under conditions of high air temperature (2.2°C) and relative high air humidity (90%), the paint prolongs the defrosting interval from 80 to 137 min. Experimental observations also show that the coated hydrophilic fins are free of frost deposition during the entire course of the test and that the coating has no significant additional thermal resistance.

[1]  Zhongliang Liu,et al.  An experimental study on minimizing frost deposition on a cold surface under natural convection conditions by use of a novel anti-frosting paint. Part I. Anti-frosting performance and comparison with the uncoated metallic surface , 2006 .

[2]  G. Tanda,et al.  Frost formation in vertical channels under natural convection , 2010 .

[3]  A. Emery,et al.  Experimental measurements of the effects of frost formation on heat exchanger performance , 1990 .

[4]  A. Sahin,et al.  Effective thermal conductivity of frost during the crystal growth period , 2000 .

[5]  Zhongliang Liu,et al.  Experimental study on frost release on fin-and-tube heat exchangers by use of a novel anti-frosting paint , 2009 .

[6]  Dennis L. O'Neal,et al.  Frosting performance of tube fin heat exchangers with wavy and corrugated fins , 1991 .

[7]  Zhongliang Liu,et al.  An experimental study on minimizing frost deposition on a cold surface under natural convection conditions by use of a novel anti-frosting paint. Part II. Long-term performance, frost layer observation and mechanism analysis , 2006 .

[8]  S. Probert,et al.  Anomalous [`]Freezing' of water in hydrophilic polymeric structures , 1989 .

[9]  R. Webb,et al.  Long-Term Hydraulic Performance of Dehumidifying Heat-Exchangers With and Without Hydrophilic Coatings , 2000 .

[10]  M. Newborough,et al.  Minimising frost growth on cold surfaces exposed to humid air by means of crosslinked hydrophilic polymeric coatings , 2000 .

[11]  R. Webb,et al.  New model for frost growth rate , 2004 .

[12]  Yujiro Hayashi,et al.  Study of Frost Properties Correlating With Frost Formation Types , 1977 .

[13]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[14]  Chin-Hsiang Cheng,et al.  PREDICTIONS OF FROST GROWTH ON A COLD PLATE IN ATMOSPHERIC AIR , 2001 .

[15]  Shuiyuan Cheng,et al.  Influences of surface hydrophilicity on frost formation on a vertical cold plate under natural convection conditions , 2007 .

[16]  Jitendra K. Gupta,et al.  Modeling of a domestic frost-free refrigerator , 2007 .