Finding the optimal length of data frame in PLC computer network

The length of data frame is an important parameter in Medium Access Control (MAC) layer protocol. A method of finding the optimal length of data frame when impulsive disturbance is involved in PowerLine Communications (PLC) is proposed. Having analyzed the characteristics of impulsive disturbance in powerline and the collision mechanism between the disturbance and data frame, this letter gives the function of the network channel utilization with the length of data frame in MAC layer and the impulsive disturbance. Our stochastic process simulation shows that it is feasible to get the optimal length of data frame.

[1]  Michael Propp,et al.  Reliable 100 kbps low-voltage ac powerline communications , 1995, Other Conferences.

[2]  Ian F. Akyildiz,et al.  Medium access control protocols for multimedia traffic in wireless networks , 1999, IEEE Netw..

[3]  Abdelfatteh Haidine,et al.  Modeling MAC layer for powerline communications networks , 2001, SPIE Optics East.

[4]  Roger Vines,et al.  Noise on Residential Power Distribution Circuits , 1984, IEEE Transactions on Electromagnetic Compatibility.

[5]  Olaf G. Hooijen On the channel capacity of the residential power circuit used as a digital communications medium , 1998, IEEE Communications Letters.

[6]  G. Marubayashi,et al.  Spread spectrum transmission on residential power line , 1996, Proceedings of ISSSTA'95 International Symposium on Spread Spectrum Techniques and Applications.

[7]  Khalid Begain,et al.  Suitable MAC Protocols for an OFDM Based PLC Network , 1988 .