Use of fiber Bragg grating sensors for monitoring concrete structures with prestressed near-surface mounted carbon fiber–reinforced polymer strips

Prestressed fiber–reinforced polymer composites have gained popularity as a structural rehabilitation technique; however, the prestress loss remains a critical issue in terms of material efficiency and structure safety. This article presents a fiber Bragg grating–based technique for prestress loss monitoring in reinforced concrete beams strengthened by prestressed near-surface mounted carbon fiber–reinforced polymer strips. Bare fiber Bragg grating sensors are used to monitor the time history of the prestress loss in near-surface mounted strips with different prestress levels during both the construction stage and the ultimate loading phase. The prestress losses measured by the fiber Bragg grating sensors are further compared with the data reported by the conventional electrical strain gauges. The results show that the fiber Bragg grating sensors can effectively monitor the prestress loss when properly integrated into the near-surface mounted strips. They also provide a reliable method for crack damage detection in concrete.

[1]  Genda Chen,et al.  A Smart Steel Strand for the Evaluation of Prestress Loss Distribution in Post-tensioned Concrete Structures , 2009 .

[2]  A. Machida,et al.  Fiber-Reinforced Polymer Composites for Construction—State-of-the-Art Review , 2002 .

[3]  Gabriel Lee Stockdale Generalized processing of FBG/FRP strain data for structural health monitoring , 2012 .

[4]  R. L. Idriss,et al.  Monitoring of an interstate highway bridge from construction thru service with a built-in fiber optic sensor system , 2007, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[5]  C. Czaderski,et al.  Effects of Gradually Anchored Prestressed CFRP Strips Bonded on Prestressed Concrete Beams , 2008 .

[6]  M. Leblanc,et al.  Continuous arbitrary strain profile measurements with fiber Bragg gratings , 1998 .

[7]  Luc Taerwe,et al.  Testing of a Prestressed Concrete Girder to Study the Enhanced Performance of Monitoring by Integrating Optical Fiber Sensors , 2007 .

[9]  R. Ogorkiewicz Linear elastic characteristics of a cast epoxy resin , 1973 .

[10]  T. K. Gangopadhyay,et al.  Fibre Bragg gratings in structural health monitoring—Present status and applications , 2008 .

[11]  Dongkeun Lee,et al.  Assessing the Strengthening Effect of Various Near-Surface-Mounted FRP Reinforcements on Concrete Bridge Slab Overhangs , 2011 .

[12]  A. Mirmiran,et al.  Creep and Durability of Environmentally Conditioned FRP-RC Beams Using Fiber Optic Sensors , 2002 .

[13]  Nobuo Takeda,et al.  Monitoring of Delamination Growth in CFRP Laminates using Chirped FBG Sensors , 2008 .

[14]  Zhishen Wu,et al.  Self-Diagnosis of Hybrid CFRP Rods and As-Strengthened Concrete Structures , 2006 .

[15]  Reflectivity and Braggs Wavelength in FBG , 2011 .

[16]  K. Peters,et al.  Damage Identification After Impact in Sandwich Composites Through Embedded Fiber Bragg Sensors , 2011 .

[17]  Shan-Tung Tu,et al.  In situ monitoring on prestress losses in the reinforced structure with fiber-optic sensors , 2009 .

[18]  Yanlei Wang,et al.  Experimental testing of a self-sensing FRP-concrete composite beam using FBG sensors , 2009, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[19]  J.A. Rice,et al.  Young's Modulus and Thermal Expansion of Filled Cyanate Ester and Epoxy Resins , 2009, IEEE Transactions on Applied Superconductivity.

[20]  R. Kashyap Fiber Bragg Gratings , 1999 .

[21]  M. Dupont,et al.  Embedded Fiber Bragg Grating Sensors for Industrial Composite Cure Monitoring , 1998 .

[22]  S. E. Watkins,et al.  Smart bridges with fiber-optic sensors , 2003 .

[23]  V. Altuzar,et al.  Atmospheric pollution profiles in Mexico City in two different seasons , 2003 .

[24]  Jeffrey S. Russell,et al.  A model specification for FRP composites for civil engineering structures , 2003 .

[25]  K. Soudki,et al.  Evaluation of the transfer length of prestressed near surface mounted CFRP rods in concrete , 2011 .

[26]  Bars Strengthening of Impacted Prestressed Concrete Bridge I-Girder Using Prestressed Near Surface Mounted CFRP , 2006 .