Wall Shear Stress Estimation of Thoracic Aortic Aneurysm Using Computational Fluid Dynamics

An attempt has been made to evaluate the effects of wall shear stress (WSS) on thoracic aortic aneurysm (TAA) using Computational Fluid Dynamics (CFD). Aneurysm is an excessive localized swelling of the arterial wall due to many physiological factors and it may rupture causing shock or sudden death. The existing imaging modalities such as MRI and CT assist in the visualization of anomalies in internal organs. However, the expected dynamic behaviour of arterial bulge under stressed condition can only be effectively evaluated through mathematical modelling. In this work, a 3D aneurysm model is reconstructed from the CT scan slices and eventually the model is imported to Star CCM+ (Siemens, USA) for intensive CFD analysis. The domain is discretized using polyhedral mesh with prism layers to capture the weakening boundary more accurately. When there is flow reversal in TAA as seen in the velocity vector plot, there is a chance of cell damage causing clots. This is because of the shear created in the system due to the flow pattern. It is observed from the proposed mathematical modelling that the deteriorating WSS is an indicator for possible rupture and its value oscillates over a cardiac cycle as well as over different stress conditions. In this model, the vortex formation pattern and flow reversals are also captured. The non-Newtonian model, including a pulsatile flow instead of a steady average flow, does not overpredict the WSS (15.29 Pa compared to 16 Pa for the Newtonian model). Although in a cycle the flow behaviour is laminar-turbulent-laminar (LTL), utilizing the non-Newtonian model along with LTL model also overpredicted the WSS with a value of 20.1 Pa. The numerical study presented here provides good insight of TAA using a systematic approach to numerical modelling and analysis.

[1]  F. Grosveld,et al.  Atherosclerotic Lesion Size and Vulnerability Are Determined by Patterns of Fluid Shear Stress , 2006, Circulation.

[2]  J D Janssen,et al.  Numerical analysis of steady generalized Newtonian blood flow in a 2D model of the carotid artery bifurcation. , 1993, Biorheology.

[3]  Shewaferaw S Shibeshi,et al.  The Rheology of Blood Flow in a Branched Arterial System. , 2005, Applied rheology.

[4]  P. J. Gamez-Montero,et al.  ESTIMATION OF WALL SHEAR STRESS USING 4D FLOW CARDIOVASCULAR MRI AND COMPUTATIONAL FLUID DYNAMICS , 2017 .

[5]  S. Thom,et al.  Analysis of flow patterns in a patient-specific thoracic aortic aneurysm model , 2009 .

[6]  Alessandro Borghi,et al.  3D geometric reconstruction of thoracic aortic aneurysms , 2006, Biomedical engineering online.

[7]  H N Sabbah,et al.  Turbulent Blood Flow in the Ascending Aorta of Humans with Normal and Diseased Aortic Valves , 1976, Circulation research.

[8]  W. Boonn,et al.  A modern experience with saccular aortic aneurysms. , 2013, Journal of vascular surgery.

[9]  van de Fn Frans Vosse,et al.  The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90° curved tube , 1999 .

[10]  F. Menter,et al.  A Correlation-Based Transition Model Using Local Variables: Part I — Model Formulation , 2004 .

[11]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[12]  Raimund Erbel,et al.  Aortic dimensions and the risk of dissection , 2005, Heart.

[13]  E. Edelman,et al.  Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling: molecular, cellular, and vascular behavior. , 2007, Journal of the American College of Cardiology.

[14]  R. Mohiaddin,et al.  3 D geometric reconstruction of thoracic aortic aneurysms , 2015 .

[15]  W. Marsden I and J , 2012 .

[16]  Charles Taylor,et al.  EXPERIMENTAL AND COMPUTATIONAL METHODS IN CARDIOVASCULAR FLUID MECHANICS , 2004 .

[17]  Aike Qiao,et al.  Study on hemodynamics in patient-specific thoracic aortic aneurysm , 2011 .

[18]  D. Fletcher,et al.  Thoracic aortic aneurysm: 4D flow MRI and computational fluid dynamics model , 2015, Computer methods in biomechanics and biomedical engineering.

[19]  L. Wann,et al.  Doppler echocardiographic measurement of flow velocity in the ascending aorta during supine and upright exercise. , 1985, British heart journal.

[20]  G. Wagner,et al.  Re: Blood flow analysis of the aortic arch using computational fluid dynamics. , 2016, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[21]  Khalil Khanafer,et al.  Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture , 2006, Annals of the New York Academy of Sciences.

[22]  D. Ku,et al.  Role of high shear rate in thrombosis. , 2015, Journal of vascular surgery.

[23]  Keiichi Itatani,et al.  Blood flow analysis of the aortic arch using computational fluid dynamics. , 2016, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[24]  Kamarul Arifin Ahmad,et al.  Computational fluid dynamics study in biomedical applications: a review , 2016 .

[25]  Y. Cho,et al.  Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: Steady flows. , 1991, Biorheology.

[27]  D. Ku,et al.  The effects of non-Newtonian viscoelasticity and wall elasticity on flow at a 90° bifurcation , 1986 .

[28]  Ali Cemal Benim,et al.  Simulation of blood flow in human aorta with emphasis on outlet boundary conditions , 2011 .

[29]  D. Steinman,et al.  Simulation of non-Newtonian blood flow in an end-to-side anastomosis. , 1994, Biorheology.