Design of Transformer with Flexible Vector Group Combinations and Adjustable Voltage Levels

An electrical power transmission and distribution systems uses many transformers in their substations with different vector groups and voltage levels. To assure reliability of the supply, the utility companies need to maintain spare transformers of all those vector groups and voltage levels. This results into increased cost and occupies lot of space. This paper describes design of a transformer, which enables different vector group combinations with different voltage level operations. Transformer design with YNd1 and YNyn0 vector group combinations is studied. Percentage winding reactance is computed using analytical, two dimensional (2-D) magnetostatic finite element method (FEM) and circuit approach. With proposed flexibility of transformer connections, number of spare transformers can be reduced, thus saving of initial investment and space can be achieved.

[1]  K. K. Paluev,et al.  Transformer Circuit Impedance Calculation , 1936, Transactions of the American Institute of Electrical Engineers.

[2]  F. O. Blackwell Y or Δ Connection of Transformers , 1903, Transactions of the American Institute of Electrical Engineers.

[3]  Monika Jain,et al.  Comparison of Star/Delta and Zig/Zag transformer based DSTATCOM for power quality improvement , 2016, 2016 IEEE Students' Conference on Electrical, Electronics and Computer Science (SCEECS).

[4]  J.V. Milanovic,et al.  The influence of transformer winding connections on the propagation of voltage sags , 2006, IEEE Transactions on Power Delivery.

[5]  Cristina Prodan,et al.  Conclusions about the study of the special connections at the three-phase transformers , 2012, 2012 International Conference and Exposition on Electrical and Power Engineering.

[6]  Walter C. Bloomquist Select the Right Transformer Winding Connection for Industrial Power Systems , 1975, IEEE Transactions on Industry Applications.

[7]  Leslie F. Curtis The Effect of Delta and Star Connections upon Transformer Wave Forms , 1914, Transactions of the American Institute of Electrical Engineers.

[8]  K. Malmedal,et al.  Application guidelines for transformer connection and grounding for distributed generation: An update , 2013, 2013 IEEE IAS Electrical Safety Workshop.

[9]  E. Sorrentino,et al.  Multipliers to Shift the Through-Fault Protection Curve for Various Connections of Distribution Transformers , 2011, IEEE Transactions on Power Delivery.

[10]  R. T. Ugale,et al.  Analytical and FEM design of autotransformer with phase shifting capability by Intermediate Voltage variation , 2016, 2016 XXII International Conference on Electrical Machines (ICEM).

[11]  Rajaram Tukaram Ugale,et al.  Intermediate Voltage Variation-Based Interconnecting Transformer Design for Voltage and Phase Angle Control With Coupled Field FEA Studies , 2018, IEEE Transactions on Industrial Electronics.

[12]  Louis F. Blume Influence of Transformer Connections on Operation , 1914, Transactions of the American Institute of Electrical Engineers.

[13]  T.-H. Chen,et al.  Models of grounded mid-tap open-wye and open-delta connected transformers for rigorous analysis of a distribution system , 1996 .

[14]  Zhen Wang,et al.  A cascaded DSTATCOM integrated with D-Y connection distribution transformer for reactive power compensation , 2017, 2017 IEEE Industry Applications Society Annual Meeting.