Integrated Design of Wideband Omnidirectional Antenna and Electronic Components for Wireless Capsule Endoscopy Systems

This paper presents a wideband antenna with omnidirectional radiation pattern for wireless capsule endoscopy (WCE) systems. The proposed antenna radiates as slot structure formed between a central copper cylinder and a copper strip attached to the interior surface of biocompatible polyimide shell. Main features of the antenna include: 1) an integrated design of the antenna and electronic components in the capsule is employed. And by utilizing the entire inner space of the capsule, the radiating aperture of antenna is increased to the maximum; 2) the copper cylinder can be used to house electronic components, therefore the potential electromagnetic interferences brought by battery and electronic circuits are reduced to the minimum; 3) the antenna in tissue has a wide bandwidth from 0.721 to 1.705 GHz, covering both 0.902–0.928-GHz industrial, scientific, and medical band and 1.395–1.4-GHz wireless medical telemetry service band; and 4) the antenna inside human tissues has stable omnidirectional radiation patterns across all operating frequencies. This is an indispensable characteristic due to unpredictable orientation of the capsule in gastrointestinal tract. The integrated design concept, wideband impedance matching, and stable omnidirectional radiation patterns make the proposed antenna a promising candidate for future WCE system.

[1]  L. Le Coq,et al.  Robust Ultraminiature Capsule Antenna for Ingestible and Implantable Applications , 2017, IEEE Transactions on Antennas and Propagation.

[2]  B. Fuchs,et al.  The Effect of Insulating Layers on the Performance of Implanted Antennas , 2011, IEEE Transactions on Antennas and Propagation.

[3]  Cheolbok Kim,et al.  A Compact Omnidirectional Self-Packaged Patch Antenna With Complementary Split-Ring Resonator Loading for Wireless Endoscope Applications , 2011, IEEE Antennas and Wireless Propagation Letters.

[4]  Y. Rahmat-Samii,et al.  Conformal Ingestible Capsule Antenna: A Novel Chandelier Meandered Design , 2009, IEEE Transactions on Antennas and Propagation.

[5]  Minkyu Je,et al.  Design and in Vitro Test of a Differentially Fed Dual-Band Implantable Antenna Operating at MICS and ISM Bands , 2014, IEEE Transactions on Antennas and Propagation.

[6]  Young Joong Yoon,et al.  Small spiral antenna for wideband capsule endoscope system , 2006 .

[7]  W. Geyi Physical limitations of antenna , 2003 .

[8]  Minkyu Je,et al.  Differentially Fed Dual-Band Implantable Antenna for Biomedical Applications , 2012, IEEE Transactions on Antennas and Propagation.

[9]  David E. Senior,et al.  An Omnidirectional Wrappable Compact Patch Antenna for Wireless Endoscope Applications , 2012, IEEE Antennas and Wireless Propagation Letters.

[10]  Zhu Duan,et al.  Dual band wristband antenna with metal frame loaded for biomedical applications , 2017 .

[11]  Li-Jie Xu,et al.  Dual-band implantable antenna with circular polarisation property for ingestible capsule application , 2017 .

[12]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[13]  Hyoungsuk Yoo,et al.  A Wideband Circularly Polarized Conformal Endoscopic Antenna System for High-Speed Data Transfer , 2017, IEEE Transactions on Antennas and Propagation.

[14]  Yan Li,et al.  Orientation Insensitive Antenna With Polarization Diversity for Wireless Capsule Endoscope System , 2017, IEEE Transactions on Antennas and Propagation.

[15]  Konstantina S. Nikita,et al.  A Broadband Implantable and a Dual-Band On-Body Repeater Antenna: Design and Transmission Performance , 2014, IEEE Transactions on Antennas and Propagation.

[16]  Wen Geyi,et al.  Optimization of the Ratio of Gain to $Q$ , 2013 .

[17]  Shaoqiu Xiao,et al.  Circularly Polarized Helical Antenna for ISM-Band Ingestible Capsule Endoscope Systems , 2014, IEEE Transactions on Antennas and Propagation.

[18]  Rizwan Bashirullah,et al.  An asymmetric RF tagging IC for ingestible medication compliance capsules , 2009, 2009 IEEE Radio Frequency Integrated Circuits Symposium.

[19]  Y. Rahmat-Samii,et al.  Wireless Medical Telemetry Characterization for Ingestible Capsule Antenna Designs , 2012, IEEE Antennas and Wireless Propagation Letters.

[20]  K. Haneda,et al.  An ultrawideband conformal loop antenna for ingestible capsule endoscope system , 2016, 2016 10th European Conference on Antennas and Propagation (EuCAP).

[21]  Rizwan Bashirullah,et al.  Printed capsule antenna for medication compliance monitoring , 2007 .

[22]  Li-Jie Xu,et al.  Metal frame repeater antenna with partial slotted ground for bandwidth enhancement of wristband devices , 2017 .

[23]  S. Nam,et al.  Outer-Wall Loop Antenna for Ultrawideband Capsule Endoscope System , 2010, IEEE Antennas and Wireless Propagation Letters.

[24]  Li-Jie Xu,et al.  Differential wide band metal-frame antenna for wristband applications , 2016, 2016 IEEE MTT-S International Microwave Workshop Series on Advanced Materials and Processes for RF and THz Applications (IMWS-AMP).

[25]  Wen Geyi,et al.  A New Derivation of the Upper Bounds for the Ratio of Gain to Q , 2012, IEEE Transactions on Antennas and Propagation.

[26]  M. R. Yuce,et al.  Easy-to-Swallow Wireless Telemetry , 2012, IEEE Microwave Magazine.

[27]  M. R. Yuce,et al.  Easy-to-swallow antenna and propagation , 2013, IEEE Microwave Magazine.

[28]  Kihyun Kim,et al.  A Wideband Spiral Antenna for Ingestible Capsule Endoscope Systems: Experimental Results in a Human Phantom and a Pig , 2011, IEEE Transactions on Biomedical Engineering.

[29]  A. K. Skrivervik,et al.  Design, Realization and Measurements of a Miniature Antenna for Implantable Wireless Communication Systems , 2011, IEEE Transactions on Antennas and Propagation.