Torque expression in stainless steel orthodontic brackets. A systematic review.

OBJECTIVE To evaluate the quantitative effects on torque expression of varying the slot size of stainless steel orthodontic brackets and the dimension of stainless steel wire, and to analyze the limitations of the experimental methods used. MATERIALS AND METHODS In vitro studies measuring torque expression in conventional and self-ligating stainless steel brackets with a torque-measuring device, with the use of straight stainless steel orthodontic wire without second-order mechanics and without loops, coils, or auxiliary wires, were sought through a systematic review process. RESULTS Eleven articles were selected. Direct comparison of different studies was limited by differences in the measuring devices used and in the parameters measured. On the basis of the selected studies, in a 0.018 inch stainless steel bracket slot, the engagement angle ranges from 31 degrees with a 0.016 x 0.016 inch stainless steel archwire to 4.6 degrees with a 0.018 x 0.025 inch stainless steel archwire. In a 0.022 inch stainless steel bracket slot, the engagement angle ranges from 18 degrees with a 0.018 x 0.025 inch stainless steel archwire to 6 degrees with a 0.021 x 0.025 inch stainless steel archwire. Active stainless steel self-ligating brackets demonstrate an engagement angle of approximately 7.5 degrees, whereas passive stainless steel self-ligating brackets show an engagement angle of approximately 14 degrees with 0.019 x 0.025 inch stainless steel wire in a 0.022 inch slot. CONCLUSIONS The engagement angle depends on archwire dimension and edge shape, as well as on bracket slot dimension, and is variable and larger than published theoretical values. Clinically effective torque can be achieved in a 0.022 inch bracket slot with archwire torsion of 15 to 31 degrees for active self-ligating brackets and of 23 to 35 degrees for passive self-ligating brackets with a 0.019 x 0.025 inch stainless steel wire.

[1]  J. Broadbent Patient-specific treatment with variable torque straight-wire. , 2003, The Functional orthodontist.

[2]  G. Andreasen,et al.  Aligning, leveling, and torque control--a pilot study. , 1989, Angle Orthodontist.

[3]  T. Meling,et al.  The effect of second-order couple on the application of torque. , 1998, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[4]  C. K. Kesling Improving incisor torque control with nickel titanium Torque Bars. , 1999, Journal of clinical orthodontics.

[5]  J. Caruso,et al.  Deformation of metal brackets: a comparative study. , 2009, The Angle orthodontist.

[6]  J. Sheridan,et al.  In vitro torque-deformation characteristics of orthodontic polycarbonate brackets. , 1994, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[7]  R. E. Siatkowski Loss of anterior torque control due to variations in bracket slot and archwire dimensions. , 1999, Journal of clinical orthodontics : JCO.

[8]  T. Meling,et al.  On the variability of cross-sectional dimensions and torsional properties of rectangular nickel-titanium arch wires. , 1998, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[9]  E L Dellinger,et al.  A scientific assessment of the straight-wire appliance. , 1978, American journal of orthodontics.

[10]  W. Brantley,et al.  Variability of effective root torque as a function of edge bevel on orthodontic arch wires. , 1984, American journal of orthodontics.

[11]  C. Bourauel,et al.  Torque capacity of metal and polycarbonate brackets with and without a metal slot. , 2004, European journal of orthodontics.

[12]  G Rau,et al.  Concept and development of a measuring system for in vivo recording of orthodontically applied forces and torques in the multiband technique. Part I. , 1996, Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie.

[13]  T. Meling,et al.  An evaluation of the torsional moments developed in orthodontic applications. An in vitro study. , 1994, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[14]  Stephan Meyer,et al.  Torque Transmission between Square Wire and Bracket as a Function of Measurement, Form and Hardness Parameters , 2000, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie.

[15]  W. Brantley,et al.  Changes in bracket slot tolerance following recycling of direct-bond metallic orthodontic appliances. , 1982, American journal of orthodontics.

[16]  D. Bai,et al.  [Influence of loops on the torsion stiffness of rectangular wire]. , 2004, Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition.

[17]  T. Uğur,et al.  Normal faciolingual inclinations of tooth crowns compared with treatment groups of standard and pretorqued brackets. , 1997, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[18]  C. Steyn Measurement of edgewise torque force in vitro. , 1977, American journal of orthodontics.

[19]  C Bourauel,et al.  An experimental apparatus for the simulation of three-dimensional movements in orthodontics. , 1992, Journal of biomedical engineering.

[20]  S. Jones,et al.  A Study to Compare the Effects of Simulated Torquing Forces on Pre-adjusted Orthodontic Brackets , 1994, British journal of orthodontics.

[21]  P. Major,et al.  Torque expression of self-ligating brackets. , 2008, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[22]  D. Kubein-Meesenburg,et al.  The third-order angle and the maxillary incisor's inclination to the NA line. , 2007, The Angle orthodontist.

[23]  C. Bourauel,et al.  Torque Capacity of Metal and Plastic Brackets with Reference to Materials, Application, Technology and Biomechanics , 2002, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie.

[24]  T. Meling,et al.  The effect of cross-sectional dimensional variations of square and rectangular chrome-cobalt archwires on torsion. , 1998, The Angle orthodontist.

[25]  T. Meling,et al.  On mechanical properties of square and rectangular stainless steel wires tested in torsion. , 1997, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[26]  Owen Rd Torque in the base vs. torque in the face. , 1991 .

[27]  J. Bachmann Torque-Eigenschaften von Stahl- und Nitinol-Drähten , 1983, Fortschritte der Kieferorthopädie.

[28]  H. Bantleon,et al.  [Measurement of force and torque rates for the correction of vertically uprighting the anterior teeth]. , 1987, Zeitschrift fur Stomatologie.

[29]  R. Kapur-Wadhwa Physical and mechanical properties affecting torque control. , 2004, Journal of clinical orthodontics : JCO.

[30]  Creekmore Td,et al.  Dr. Thomas D. Creekmore on torque. , 1979 .

[31]  J M Powers,et al.  Torsional properties of commercial nickel-titanium wires during activation and deactivation. , 2001, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[32]  N. Pandis,et al.  Torque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic brackets. , 2008, European journal of orthodontics.

[33]  S. Ajello,et al.  [Auxiliary torque arches during the contraction phase]. , 1986, Minerva Stomatologica.

[34]  J. A. Wagner,et al.  Stiffness of incisor segments of edgewise arches in torsion and bending. , 2009, The Angle orthodontist.

[35]  D. Bai,et al.  [Incisor torque control with fixed appliance]. , 2004, Zhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi = Chinese journal of stomatology.

[36]  T. Eliades,et al.  Materials-induced variation in the torque expression of preadjusted appliances. , 2004, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[37]  L. Taft,et al.  A cephalometric study of Class II, division 1 treatment using differential torque mechanics. , 1992, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[38]  L K Rubenstein,et al.  Moments with the edgewise appliance: incisor torque control. , 1993, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[39]  Siatkowski Re Loss of anterior torque control due to variations in bracket slot and archwire dimensions. , 1999 .

[40]  N. Pandis,et al.  Maxillary incisor torque with conventional and self-ligating brackets: a prospective clinical trial. , 2006, Orthodontics & craniofacial research.