Measurement and prediction of train-induced vibrations in a full-scale building

Abstract Buildings located close to transportation corridors experience structure-borne sound and vibration due to passing traffic which can be disruptive to operation of sensitive equipment in manufacturing, and medical facilities. Structure-borne sound and vibrations, when high may also be annoying to human occupants in residential, office, and commercial buildings. Hence, there is a growing need for cost effective sound and vibration predictions to evaluate the need for mitigation. The research focuses on in-situ testing of a full-scale building for verification of a previously developed impedance-based methodology and to create a prediction model to study ground-borne vibrations in the test building. A mitigation methodology was also examined using the verified prediction model. Impedance modeling involves the propagation of axial waves through columns combined with the impedance of the intermediate floor slabs. The vibration transmission in the building was characterized and predicted using a single column model with attached floors. Train-induced floor vibrations in an existing four-story building in Boston were measured and compared with predictions of the impedance model. The impedance model predictions closely matched with the measured floor responses. A previously suggested mitigation method was investigated analytically using the impedance model. A thickened floor referred as the “blocking floor” was used on the lower elevation of the building and the reduction in vibration at the upper floors of the building was compared for various thicknesses of the blocking floor, to study its efficiency. The blocking floor has high impedance and reflects a major portion of the vibration transmitting in the columns preventing it from reaching the upper floors. The blocking floor was found to mitigate the transmission of ground-borne vibrations to upper floors.

[1]  R. Clough,et al.  Dynamics Of Structures , 1975 .

[2]  O. von Estorff,et al.  Reduction of train-induced building vibrations by using open and filled trenches , 2005 .

[3]  S. Ljunggren Transmission of structure-borne sound in buildings above railways , 1991 .

[4]  Fulop Augusztinovicz,et al.  Numerical modelling of ground-borne noise and vibration in buildings due to surface rail traffic , 2007 .

[5]  Anders Bodare,et al.  Wave barrier of lime–cement columns against train-induced ground-borne vibrations , 2009 .

[6]  Geert Lombaert,et al.  Prediction of vibrations induced by underground railway traffic in Beijing , 2007 .

[7]  Eric M. Hines,et al.  Predicting Train-Induced Vibrations in Multi-Story Buildings , 2008 .

[8]  Eric M. Hines,et al.  Prediction and Mitigation of Building Floor Vibrations Using a Blocking Floor , 2012 .

[9]  Masoud Sanayei,et al.  Measurement of building foundation and ground-borne vibrations due to surface trains and subways , 2013 .

[10]  G. Rosenhouse,et al.  Attenuation of noise and vibration caused by underground trains, using soil replacement , 2006 .

[11]  Carl E. Hanson,et al.  Transit Noise and Vibration Impact Assessment , 2006 .

[12]  S. J Cox,et al.  Effect of track stiffness on vibration levels in railway tunnels , 2003 .

[13]  Masoud Sanayei,et al.  Impedance Modeling: An Efficient Modeling Method for Prediction of Building Floor Vibrations , 2012 .

[14]  E. E. Ungar,et al.  Structure-borne sound , 1974 .

[15]  K. Massarsch Vibration Isolation Using Gas-filled Cushions , 2005 .

[16]  Dong-Guen Lee,et al.  An efficient modeling technique for floor vibration in multi-story buildings , 2000 .

[17]  Kiyoshi Sato,et al.  Development of Rail Noise Isolating Material (RNIM) , 2012 .