Shake-Table Tests of a Full-Scale Three-Story Reinforced Masonry Shear Wall Structure

AbstractThis paper presents the shake-table tests of a full-scale, 3-story, reinforced concrete masonry structure. The structure was a special reinforced masonry shear wall system designed according to current code provisions for an area of high seismicity. It consisted of three lines of walls arranged in an H-shape in plan view, with one lineal and two T-walls aligned in the direction of the table motion and four lineal walls oriented perpendicular to the table motion. The seven walls were separated by door openings and were connected with lintels and precast slabs with cast-in-place concrete topping. The structure was subjected to a series of dynamic tests including nine seismic excitations with intensities exceeding the maximum considered earthquake used in the design. The structure had a capacity that exceeded considerably the design base shear, and it withstood all but the last two excitations with little or no damage. The paper presents the design of the test structure, its dynamic response to the s...

[1]  Andreas Stavridis,et al.  System Identification of a Ten-Story RC Building at Different Damage States , 2014 .

[2]  John R. Hayes,et al.  Seismic Evaluation of Low-Rise Reinforced Masonry Buildings with Flexible Diaphragms: II. Analytical Modeling , 2004 .

[3]  Xxyyzz,et al.  Building Code Requirements and Specification for Masonry Structures : Containing Building Code Requirements for Masonry Structures (TMS 402-11/ACI 530-11/ASCE 5-11), and Specification for Masonry Structures TMS 402-11/ACI 530-11/ASCE 6-11), and Companion Commentaries , 2008 .

[4]  John R. Hayes,et al.  Seismic Evaluation of Low-Rise Reinforced Masonry Buildings with Flexible Diaphragms: I. Seismic and Quasi-Static Testing , 2004 .

[5]  N. Null Minimum Design Loads for Buildings and Other Structures , 2003 .

[6]  P. B. Shing,et al.  FLEXURE AND SHEAR REPONSE OF REINFORCED MASONRY WALLS , 1990 .

[7]  George C. Manos,et al.  Seismic Testing of Single‐Story Masonry Houses: Part 1 , 1990 .

[8]  Akira Igarashi,et al.  Simulated Seismic-Load Tests on Full-Scale Five-Story Masonry Building , 1994 .

[9]  Daniel P. Abrams,et al.  MODELING EARTHQUAKE RESPONSE OF CONCRETE MASONRY BUILDING STRUCTURES , 1991 .

[10]  Wael W. El-Dakhakhni,et al.  Shake Table Seismic Performance Assessment of Lightly Reinforced Concrete Block Shear Walls , 2015 .

[11]  Frieder Seible,et al.  Seismic Response of Full‐Scale Five‐Story Reinforced‐Masonry Building , 1994 .

[12]  Richard E. Klingner,et al.  Seismic Performance Tests of Masonry and Masonry Veneer , 2010 .

[13]  Andreas Stavridis,et al.  Shake‐table tests of a three‐story reinforced concrete frame with masonry infill walls , 2012 .