Application of SFCLs to Inhibit Commutation Failure in HVdc Systems: Position Comparison and Resistance Recommendation

Commutation failure is one of the most common failures that may lead to serious consequences in high-voltage direct current (HVdc) systems. Superconducting fault current limiters (SFCLs) have been proved effective to inhibit commutation failures. In this paper, different installation positions of SFCLs are compared through three proposed evaluation indexes. The position between ac and dc systems is proved to have the best performance, and the position at the end of dc line performs moderately but costs less. Then, methods for calculating the convergence resistance of the SFCL are recommended. The theoretical method can draw the lower limit of the resistance quickly and reduce simulation time drastically when SFCLs are installed between ac and dc systems. In addition, an improved structure is presented to ensure fast recovery of an SFCL, so that the system can be restored quickly when the fault disappears. Simulations are carried out on PSCAD/EMTDC against the CIGRE HVdc benchmark system to verify the validity of the proposed installation scheme.

[1]  Arsalan Hekmati Proposed Design for a Tunable Inductive Shield-Type SFCL , 2014, IEEE Transactions on Applied Superconductivity.

[2]  J. Baba,et al.  Recovery Characteristics of SFCL by Use of Y123 Thin Film , 2007, IEEE Transactions on Applied Superconductivity.

[3]  Zheng Xu,et al.  Inverter location analysis for multi-infeed HVDC systems , 2010, 2010 International Conference on Power System Technology.

[4]  Dong Keun Park,et al.  Study on a Series Resistive SFCL to Improve Power System Transient Stability: Modeling, Simulation, and Experimental Verification , 2009, IEEE Transactions on Industrial Electronics.

[5]  Yonghui Sun,et al.  Direct-Current Predictive Control Strategy for Inhibiting Commutation Failure in HVDC Converter , 2014, IEEE Transactions on Power Systems.

[6]  J. B. Davies,et al.  Commutation failures in HVDC transmission systems , 1996 .

[7]  Dong Keun Park,et al.  Recovery Characteristics of Resistive SFCL Wound With YBCO Coated Conductor in a Power System , 2007, IEEE Transactions on Applied Superconductivity.

[8]  A. Hansen,et al.  Decreasing the commutation failure frequency in HVDC transmission systems , 2000 .

[9]  Arsalan Hekmati Multiobjective Design of Tunable Shield-Type Superconducting Fault Current Limiter , 2015, IEEE Transactions on Applied Superconductivity.

[10]  Jung-Wook Park,et al.  Effect of a SFCL on Commutation Failure in a HVDC System , 2013, IEEE Transactions on Applied Superconductivity.

[11]  Ling Peng,et al.  Design a Fuzzy Controller to Minimize the Effect of HVDC Commutation Failure on Power System , 2008, IEEE Transactions on Power Systems.

[12]  Hongyang Huang,et al.  Two new techniques to solve the problems with multi-infeed HVDC systems , 2014, 2014 International Conference on Power System Technology.

[13]  Lei Chen,et al.  Study on the Application of a Flux-Coupling-Type Superconducting Fault Current Limiter for Decreasing HVdc Commutation Failure , 2015, Canadian Journal of Electrical and Computer Engineering.

[14]  Yong-Sun Cho,et al.  Critical Current Equalization via Neutral Lines in a Transformer-Type SFCL , 2008, IEEE Transactions on Applied Superconductivity.

[15]  Mathias Noe,et al.  High-temperature superconductor fault current limiters: concepts, applications, and development status , 2007 .

[16]  Campbell Booth,et al.  Comparison of different technologies for improving commutation failure immunity index for LCC HVDC in weak AC systems , 2015 .

[17]  Jae-Chul Kim,et al.  Study on Coordination of Protective Relays Between Primary Feeder and Interconnecting Transformer Grounded by SFCL of Wind Farm , 2012, IEEE Transactions on Applied Superconductivity.

[18]  Brett Davies,et al.  Commutation Failure Analysis in Multi-Infeed HVDC Systems , 2011, IEEE Transactions on Power Delivery.

[19]  Chunyi Guo,et al.  Power Component Fault Detection Method and Improved Current Order Limiter Control for Commutation Failure Mitigation in HVDC , 2015, IEEE Transactions on Power Delivery.

[20]  Chul-Hwan Kim,et al.  Quench and Recovery Characteristics of a SFCL Applied Into Neutral Line of a Three-Phase Power System , 2009, IEEE Transactions on Applied Superconductivity.

[21]  Sang-Yun Yun,et al.  Assessment of the Impact of SFCL on Voltage Sags in Power Distribution System , 2011, IEEE Transactions on Applied Superconductivity.