A rules of thumb-based design sequence for diffuse daylight

This paper proposes and validates a daylighting design sequence for sidelit spaces. Since the design sequence uses the daylight factor as a performance metric, it is aimed towards spaces that primarily receive diffuse daylight. It should be complemented by a design analysis that looks at direct sunlight for glare and energy considerations. The sequence interconnects and refines earlier proposed rules of thumb and is intended to be used during the earliest design stages when concepts regarding programming, floor plans, massing and window areas are initially explored. All steps within the sequence were ‘validated’ using Radiance simulations of over 2300 sidelit spaces. During step one of the sequence the effective sky angles are calculated and target daylight factors are defined for all potential daylit zones within a building. In step two a refined version of the ‘daylight feasibility study’ is used to help the design team to identify building zones with high daylighting potential based on a target mean daylight factor criterion. During step three suitable interior room dimensions and surface reflectances are determined using a combination of the Lynes’ limiting depth, ‘no sky line’, and window-head-height rules of thumb. Step four provides a more accurate estimate of the required glazing area for each zone based on the Lynes daylight factor formula which is also validated as part of this work. The effect of external obstructions is considered throughout the process. The paper closes with a discussion of the merits of the design sequence compared to the glazing factor spreadsheet calculation method promoted by LEED-NC 2.2.

[1]  J. A. Lynes,et al.  A sequence for daylighting design , 1979 .

[2]  Christoph F. Reinhart,et al.  Findings from a survey on the current use of daylight simulations in building design , 2006 .

[3]  L. Roche,et al.  Occupant reactions to daylight in offices , 2000 .

[4]  Christoph F. Reinhart,et al.  DAYLIGHT1-2-3 - A STATE-OF-THE-ART DAYLIGHTING/ENERGY ANALYSIS SOFTWARE FOR INITIAL DESIGN INVESTIGATIONS , 2007 .

[5]  C. Reinhart,et al.  A SIMULATION-BASED REVIEW OF THE UBIQUITOUS WINDOW-HEAD-HEIGHT TO DAYLIT ZONE DEPTH RULE-OF-THUMB , 2005 .

[6]  C. Reinhart,et al.  DAYLIGHT FACTOR SIMULATIONS – HOW CLOSE DO SIMULATION BEGINNERS ‘ REALLY ’ GET ? , 2009 .

[7]  Christoph F. Reinhart,et al.  Validation of dynamic RADIANCE-based daylight simulations for a test office with external blinds , 2001 .

[8]  P. Tregenza The daylight factor and actual illuminance ratios , 1980 .

[9]  John Mardaljevic,et al.  Validation of a lighting simulation program under real sky conditions , 1995 .

[10]  Isaac Guedi Capeluto The influence of the urban environment on the availability of daylighting in office buildings in Israel , 2003 .

[11]  Robin Mitchell,et al.  COMFEN: A COMMERCIAL FENESTRATION/FAÇADE DESIGN TOOL , 2008 .

[12]  Christoph F. Reinhart,et al.  Current daylighting design practice: a survey , 2008 .

[13]  offices Reinhart Effects of Interior Design on the Daylight Availability in Open Plan Offices , 2002 .

[14]  John Mardaljevic,et al.  Dynamic Daylight Performance Metrics for Sustainable Building Design , 2006 .

[15]  John Mardaljevic Quantification of parallax errors in sky simulator domes for clear sky conditions , 2002 .

[16]  S W A Cannon-Brookes,et al.  Simple scale models for daylighting design: Analysis of sources of error in illuminance predictiont , 1997 .