Polyetherimide: a new membrane-forming polymer for biomedical applications.

Membranes for biohybrid organs such as the biohybrid liver support system have to face 2 different environments, namely blood and tissue cells. Accordingly, the respective membrane surfaces must have optimal properties in terms of biocompatibility for blood or tissue. Flat membranes prepared by a phase inversion process from polyetherimide were modified by binding of tris-(hydroxymethyl)-aminomethane to obtain a surface with hydroxyl groups by binding of polyethylene imine to attach a hydrophilic macromolecule with amine groups useful as a spacer for later bonding of further ligands and by attachment of heparin. The binding of the different ligands was successful as monitored by different physicochemical methods. The blood response of plain polyetherimide was comparable to that of polyacrylonitrile, and it could be further improved by the binding of heparin. The tissue compatibility of polyetherimide and its different modifications was compared with commercial cell culture substrate membranes (Millicell) and found to be comparable for polyetherimide and even better after the modification with tris-(hydroxymethyl)-aminomethane. In conclusion, polyetherimide seems to be an interesting material for the production of membranes for application in biohybrid organ systems.

[1]  M. Kazatchkine,et al.  The Human Alternative Complement Pathway : Biology and Immunopathology of Activation and Regulation1 , 1982 .

[2]  V. B. Ivanov,et al.  Determination of Functional Groups on Polymer Surfaces Using FluorescenceLabelling , 1996 .

[3]  O. Blétry,et al.  Medical nephrectomy with CsA and angiotensin II in a case of life-threatening membranous glomerulonephritis. , 1994, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[4]  H. Klinkmann,et al.  Comparative Evaluation of Different Membranes for the Construction of an Artificial Liver Support System , 1997, The International journal of artificial organs.

[5]  U. Christians,et al.  Reconstruction of liver tissue in vitro: geometry of characteristic flat bed, hollow fiber, and spouted bed bioreactors with reference to the in vivo liver. , 1995, Artificial organs.

[6]  V. Dixit Development of a bioartificial liver using isolated hepatocytes. , 1994, Artificial organs.

[7]  L. V. von Segesser,et al.  Flow Rate Dependent Ex Vivo Deheparinization With Immobilized Cationic Ligand , 1997, ASAIO journal.

[8]  Dieter Paul Polymermembranen für die Stofftrennung , 1998 .

[9]  W. Reichert,et al.  Polyimides as biomaterials: preliminary biocompatibility testing. , 1993, Biomaterials.

[10]  P. K. Smith,et al.  Colorimetric method for the assay of heparin content in immobilized heparin preparations. , 1980, Analytical biochemistry.

[11]  C. Colton,et al.  Implantable biohybrid artificial organs. , 1995, Cell transplantation.

[12]  T. Groth,et al.  Contact activation of plasmatic coagulation on polymeric membranes measured by the activity of kallikrein in heparinized plasma. , 1997, Journal of biomaterials science. Polymer edition.

[13]  S. Nunes,et al.  Poly(ether imide) membranes obtained from solution in cosolvent mixtures , 1998 .

[14]  P. Romaniuk,et al.  Covalent immobilization of hirudin improves the haemocompatibility of polylactide-polyglycolide in vitro. , 1997, Biomaterials.

[15]  K. Richau,et al.  Electrochemical characterization of charged membranes and membrane systems , 1996 .

[16]  J. Vienken,et al.  Membranes for dialysis. , 1994, Casopis lekaru ceskych.

[17]  N. Chowdhury,et al.  Use of mammalian liver cells for artificial liver support. , 1996, Cell transplantation.

[18]  K. Peinemann,et al.  Preparation of hollow fiber membranes from polyetherimide for gas separation , 1992 .

[19]  H. Hirasawa,et al.  Efficacy and limitation of apheresis therapy in critical care. , 1997, Therapeutic apheresis : official journal of the International Society for Apheresis and the Japanese Society for Apheresis.

[20]  J. Vienken,et al.  Considerations on developmental aspects of biocompatible dialysis membranes. , 1995, Artificial organs.

[21]  J. Vienken,et al.  Focusing on membranes. , 2008, Artificial organs.

[22]  H. Handa,et al.  Blood compatibility of hydrophilic polymers. , 1981, Journal of biomedical materials research.

[23]  T. Groth,et al.  Development of membranes for the cultivation of kidney epithelial cells. , 2000, Biomaterials.

[24]  J. Zwischenberger,et al.  Adult extracorporeal membrane oxygenation for severe respiratory failure , 1998, Perfusion.

[25]  J. Rozga,et al.  Artificial liver. Evolution and future perspectives. , 1995, ASAIO journal.

[26]  Y. Imai,et al.  Structure-biocompatibility relationship of condensation polymers. , 1983, Journal of biomedical materials research.

[27]  Y. Ikada,et al.  Sorption of low-molecular-weight anions into thin polycation layers grafted onto a film , 1993 .

[28]  D. Williams,et al.  Plasma recalcification as a measure of contact phase activation and heparinization efficacy after contact with biomaterials. , 1994, Biomaterials.

[29]  Luigi Nicolais,et al.  Polyetherimide as biomaterial: preliminary in vitro and in vivo biocompatibility testing , 1994 .

[30]  D. Paul,et al.  The relation between Young’s equilibrium contact angle and the hysteresis on rough paraffin wax surfaces , 1999 .