Induction motors' faults detection and localization using stator current advanced signal processing techniques

The knowledge about fault mode behavior of an induction motor drive system is extremely important from the standpoint of improved system design, protection, and fault-tolerant control. This paper addresses the application of motor current spectral analysis for the detection and localization of abnormal electrical and mechanical conditions that indicate, or may lead to, a failure of induction motors. Intensive research effort has been for some time focused on the motor current signature analysis. This technique utilizes the results of spectral analysis of the stator current. Reliable interpretation of the spectra is difficult since distortions of the current waveform caused by the abnormalities in the induction motor are usually minute. This paper takes the initial step to investigate the efficiency of current monitoring for diagnostic purposes. The effects of stator current spectrum are described and the related frequencies determined. In the present investigation, the frequency signature of some asymmetrical motor faults are well identified using advanced signal processing techniques, such as high-resolution spectral analysis. This technique leads to a better interpretation of the motor current spectra. In fact, experimental results clearly illustrate that stator current high-resolution spectral analysis is very sensitive to induction motor faults modifying main spectral components, such as voltage unbalance and single-phasing effects.

[1]  Gerald Burt Kliman,et al.  Methods of Motor Current Signature Analysis , 1992 .

[2]  Thomas G. Habetler,et al.  An unsupervised, on-line system for induction motor fault detection using stator current monitoring , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.

[3]  Tommy W. S. Chow,et al.  Three phase induction machines asymmetrical faults identification using bispectrum , 1995 .

[4]  Thomas A. Lipo,et al.  A new approach to motor condition monitoring in induction motor drives , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[5]  T.G. Habetler,et al.  Motor bearing damage detection using stator current monitoring , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.

[6]  G.C. Soukup,et al.  Cause and analysis of stator and rotor failures in 3-phase squirrel cage induction motors , 1991, Conference Record of 1991 Annual Pulp and Paper Industry Technical Conference.

[7]  W. T. Thomson,et al.  Vibration and current monitoring for detecting airgap eccentricity in large induction motors , 1986 .

[8]  W. M. Carey,et al.  Digital spectral analysis: with applications , 1986 .

[9]  P.G. McLaren,et al.  Reliability improvement and economic benefits of on-line monitoring systems for large induction machines , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[10]  W. Deleroi Der Stabbruch im Käfigläufer eines Asynchronmotors , 1984 .

[11]  A.M. Trzynadlowski,et al.  Instantaneous stator power as a medium for the signature analysis of induction motors , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[12]  J. Penman,et al.  Condition monitoring of electrical drives , 1986 .

[13]  D. J. Tilak Siyambalapitiya,et al.  A Rotor Condition Monitor for Squirrel-Cage Induction Machines , 1987, IEEE Transactions on Industry Applications.

[14]  Peter Tavner Condition monitoring-the way ahead for large electrical machines , 1989 .

[15]  R. Maier,et al.  Protection of squirrel cage induction motor utilizing instantaneous power and phase information , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[16]  S. Venkata,et al.  An Adaptive Power Factor Controller for Three-Phase Induction Generators , 1985, IEEE Transactions on Power Apparatus and Systems.