Manual landmark identification and tracking during the medial rotation test of the shoulder: an accuracy study using three-dimensional ultrasound and motion analysis measures.

Palpation of movement is a common clinical tool for assessment of movement in patients with musculoskeletal symptoms. The purpose of this study was to measure the accuracy of palpation of shoulder girdle translation during the medial rotation test (MRT) of the shoulder. The translation of the gleno-humeral and scapulo-thoracic joints was measured using both three-dimensional ultrasound and palpation in order to determine the accuracy of translation tracking during the MRT of the shoulder. Two movements of 11 normal subjects (mean age 24 (SD=4), range 19-47 years) were measured. The agreement between measures was good for scapulo-thoracic translation (r=0.83). Gleno-humeral translation was systematically under estimated (p=0.03) although moderate correlation was found (r=0.65). These results indicate that translation of the measured joints can be tracked by palpation and further tests of the efficacy of palpation tracking during musculoskeletal assessment may be warranted.

[1]  J A Sidles,et al.  Translation of the humeral head on the glenoid with passive glenohumeral motion. , 1990, The Journal of bone and joint surgery. American volume.

[2]  Thomas M Cook,et al.  Translations of the humerus in persons with shoulder impingement symptoms. , 2002, The Journal of orthopaedic and sports physical therapy.

[3]  K. An,et al.  Biomechanics of the Shoulder , 2009 .

[4]  E. Audenaert,et al.  About the variability of the shape of the glenoid cavity , 2004, Surgical and Radiologic Anatomy.

[5]  M Pagano,et al.  Simple linear regression and correlation, continued. , 1995, Nutrition.

[6]  S. Mottram,et al.  Movement and stability dysfunction--contemporary developments. , 2001, Manual therapy.

[7]  Robert H. Cofield,et al.  The Shoulder. 3rd ed. , 2005 .

[8]  H E Veeger,et al.  The position of the rotation center of the glenohumeral joint. , 2000, Journal of biomechanics.

[9]  A. Anderson,et al.  Instrumented evaluation of knee laxity: A comparison of five arthrometers , 1992, The American journal of sports medicine.

[10]  Thomas M. Cook,et al.  Comparison of Surface Sensor and Bone-Fixed Measurement of Humeral Motion , 2002 .

[11]  B F Morrey,et al.  Dynamic Glenohumeral Stability Provided by the Rotator Cuff Muscles in the Mid-Range and End-Range of Motion: A Study in Cadavera* , 2000, The Journal of bone and joint surgery. American volume.

[12]  Christian Gerber,et al.  The effect of capsular tightening on humeral head translations , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[13]  G R Johnson,et al.  The measurement of three dimensional scapulohumeral kinematics--a study of reliability. , 1999, Clinical biomechanics.

[14]  P M Rozing,et al.  The glenohumeral joint rotation centre in vivo. , 2000, Journal of biomechanics.

[15]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[16]  B. Beynnon,et al.  In Vivo Technique to Quantify the Internal-External Rotation Kinematics of the Human Glenohumeral Joint , 2000 .

[17]  L. Soslowsky,et al.  Interplay of the static and dynamic restraints in glenohumeral instability. , 2002, Clinical orthopaedics and related research.