A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting

This paper presents the design, modeling and experimental evaluation of a magnetic resonance imaging (MRI)-compatible concentric tube continuum robotic system. This system enables MRI-guided deployment of a precurved and steerable concentric tube continuum mechanism, and is suitable for clinical applications where a curved trajectory is needed. This compact 6 degree-of-freedom (DOF) robotic system is piezoelectrically-actuated, and allows simultaneous robot motion and imaging with no visually observable image artifact. The targeting accuracy is evaluated with optical tracking system and gelatin phantom under live MRI-guidance with Root Mean Square (RMS) errors of 1.94 and 2.17 mm respectively. Furthermore, we demonstrate that the robot has kinematic redundancy to reach the same target through different paths. This was evaluated in both free space and MRI-guided gelatin phantom trails, with RMS errors of 0.48 and 0.59 mm respectively. As the first of its kind, MRI-guided targeted concentric tube needle placements with ex vivo porcine liver are demonstrated with 4.64 mm RMS error through closed-loop control of the piezoelectrically-actuated robot.

[1]  U-Xuan Tan,et al.  Design and Control of a 1-DOF MRI-Compatible Pneumatically Actuated Robot With Long Transmission Lines , 2011, IEEE/ASME Transactions on Mechatronics.

[2]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.

[3]  Daniel Glozman,et al.  Image-Guided Robotic Flexible Needle Steering , 2007, IEEE Transactions on Robotics.

[4]  D. Caleb Rucker,et al.  A MRI-guided concentric tube continuum robot with piezoelectric actuation: A feasibility study , 2012, 2012 IEEE International Conference on Robotics and Automation.

[5]  Shahin Sirouspour,et al.  A Pneumatically Actuated Target Stabilization Device for MRI-Guided Breast Biopsy , 2015, IEEE/ASME Transactions on Mechatronics.

[6]  A. Pelton,et al.  An overview of nitinol medical applications , 1999 .

[7]  Bo Yang,et al.  Design, development, and evaluation of a master–slave surgical system for breast biopsy under continuous MRI , 2014, Int. J. Robotics Res..

[8]  G. Fichtinger,et al.  Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention , 2013, IEEE/ASME Transactions on Mechatronics.

[9]  Guang-Zhong Yang,et al.  From Passive Tool Holders to Microsurgeons: Safer, Smaller, Smarter Surgical Robots , 2014, IEEE Transactions on Biomedical Engineering.

[10]  Hongliang Ren,et al.  An image based targeting method to guide a tentacle-like curvilinear concentric tube robot , 2014, 2014 IEEE International Conference on Robotics and Biomimetics (ROBIO 2014).

[11]  Jaydev P. Desai,et al.  Toward a Meso-Scale SMA-Actuated MRI-Compatible Neurosurgical Robot , 2012, IEEE Transactions on Robotics.

[12]  Jin Seob Kim,et al.  Nonholonomic Modeling of Needle Steering , 2006, Int. J. Robotics Res..

[13]  Dan Stoianovici,et al.  Automatic Brachytherapy Seed Placement Under MRI Guidance , 2007, IEEE Transactions on Biomedical Engineering.

[14]  Tom W J Scheenen,et al.  Feasibility of a pneumatically actuated MR-compatible robot for transrectal prostate biopsy guidance. , 2011, Radiology.

[15]  Lucas J. van Vliet,et al.  Expiration-Phase Template-Based Motion Correction of Free-Breathing Abdominal Dynamic Contrast Enhanced MRI , 2015, IEEE Transactions on Biomedical Engineering.

[16]  R. Stafford,et al.  Transurethral ultrasound applicators with directional heating patterns for prostate thermal therapy: in vivo evaluation using magnetic resonance thermometry. , 2004, Medical physics.

[17]  Nobuhiko Hata,et al.  Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy , 2015, IEEE/ASME Transactions on Mechatronics.

[18]  Paolo Dario,et al.  A Miniaturized Mechatronic System Inspired by Plant Roots for Soil Exploration , 2011, IEEE/ASME Transactions on Mechatronics.

[19]  Pierre E. Dupont,et al.  Quasistatic modeling of concentric tube robots with external loads , 2010, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[20]  Robert J. Webster,et al.  Mechanics of Precurved-Tube Continuum Robots , 2009, IEEE Transactions on Robotics.

[21]  Gregory S. Fischer,et al.  A high accuracy multi-image registration method for tracking MRI-guided robots , 2012, Medical Imaging.

[22]  D. Caleb Rucker,et al.  A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots , 2010, IEEE Transactions on Robotics.

[23]  A. Patriciu,et al.  A New Type of Motor: Pneumatic Step Motor , 2007, IEEE/ASME Transactions on Mechatronics.

[24]  Robert J. Webster,et al.  Concentric Tube Robots as Steerable Needles: Achieving Follow-the-Leader Deployment , 2015, IEEE Transactions on Robotics.

[25]  Robert Rohling,et al.  Hand-held steerable needle device , 2003, IEEE/ASME Transactions on Mechatronics.

[26]  Guang-Zhong Yang,et al.  Vision-based intraoperative shape sensing of concentric tube robots , 2015, 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[27]  Constantinos Mavroidis,et al.  Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study. , 2007, Annual review of biomedical engineering.

[28]  Gabor Fichtinger,et al.  MRI Compatibility of Robot Actuation Techniques - A Comparative Study , 2008, MICCAI.

[29]  Gang Li,et al.  Closed-loop asymmetric-tip needle steering under continuous intraoperative MRI guidance , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[30]  Hao Su,et al.  Robotic System for MRI-Guided Stereotactic Neurosurgery , 2015, IEEE Transactions on Biomedical Engineering.

[31]  D. Caleb Rucker,et al.  Guidance of a steerable cannula robot in soft tissue using preoperative imaging and conoscopic surface contour sensing , 2010, 2010 IEEE International Conference on Robotics and Automation.

[32]  T. Fielding,et al.  An image-guided magnetic resonance-compatible surgical robot. , 2008, Neurosurgery.

[33]  Pierre E. Dupont,et al.  Concentric Tube Robot Design and Optimization Based on Task and Anatomical Constraints , 2015, IEEE Transactions on Robotics.

[34]  Zion Tsz Ho Tse,et al.  An MR-Conditional High-Torque Pneumatic Stepper Motor for MRI-Guided and Robot-Assisted Intervention , 2014, Annals of Biomedical Engineering.

[35]  Gregory S. Chirikjian,et al.  Equilibrium Conformations of Concentric-tube Continuum Robots , 2010, Int. J. Robotics Res..