On-line blood viscosity monitoring in vivo with a central venous catheter, using electrical impedance technique.

Blood viscosity is an important determinant of microvascular hemodynamics and also reflects systemic inflammation. Viscosity of blood strongly depends on the shear rate and can be characterized by a two parameter power-law model. Other major determinants of blood viscosity are hematocrit, level of inflammatory proteins and temperature. In-vitro studies have shown that these major parameters are related to the electrical impedance of blood. A special central venous catheter was developed to measure electrical impedance of blood in-vivo in the right atrium. Considering that blood viscosity plays an important role in cerebral blood flow, we investigated the feasibility to monitor blood viscosity by electrical bioimpedance in 10 patients during the first 3 days after successful resuscitation from a cardiac arrest. The blood viscosity-shear rate relationship was obtained from arterial blood samples analyzed using a standard viscosity meter. Non-linear regression analysis resulted in the following equation to estimate in-vivo blood viscosity (Viscosity(imp)) from plasma resistance (R(p)), intracellular resistance (R(i)) and blood temperature (T) as obtained from right atrium impedance measurements: Viscosity(imp)=(-15.574+15.576R(p)T)SR ((-.138RpT-.290Ri)). This model explains 89.2% (R(2)=.892) of the blood viscosity-shear rate relationship. The explained variance was similar for the non-linear regression model estimating blood viscosity from its major determinants hematocrit and the level of fibrinogen and C-reactive protein (R(2)=.884). Bland-Altman analysis showed a bias between the in-vitro viscosity measurement and the in-vivo impedance model of .04 mPa s at a shear rate of 5.5s(-1) with limits of agreement between -1.69 mPa s and 1.78 mPa s. In conclusion, this study demonstrates the proof of principle to monitor blood viscosity continuously in the human right atrium by a dedicated central venous catheter equipped with an impedance measuring device. No safety problems occurred and there was good agreement with in-vitro measurements of blood viscosity.

[1]  A. Cariou,et al.  Postresuscitation disease after cardiac arrest: a sepsis-like syndrome? , 2004, Current opinion in critical care.

[2]  F. Thompson,et al.  The effect of haematocrit on the resistivity of human blood at 37°C and 100 kHz , 1975, Medical and biological engineering.

[3]  H. Meiselman,et al.  Dielectric approach to investigation of erythrocyte aggregation. II. Kinetics of erythrocyte aggregation-disaggregation in quiescent and flowing blood. , 2000, Biorheology.

[4]  H. Fricke,et al.  THE ELECTRIC RESISTANCE AND CAPACITY OF BLOOD FOR FREQUENCIES BETWEEN 800 AND 4½ MILLION CYCLES , 1925, The Journal of general physiology.

[5]  B. Jacobson,et al.  Quantitative correlations among fibrinogen concentration, sedimentation rate and electrical impedance of blood , 1997, Medical and Biological Engineering and Computing.

[6]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[7]  H. Schmid-schönbein,et al.  Custom‐Tailored Hemodilution With Albumin and Crystalloids in Acute Ischemic Stroke , 1992, Stroke.

[8]  P. Libby,et al.  Novel inflammatory markers of coronary risk: theory versus practice. , 1999, Circulation.

[9]  D. Kell,et al.  Dielectric properties of human blood and erythrocytes at radio frequencies (0.2–10 MHz); dependence on cell volume fraction and medium composition , 2005, European Biophysics Journal.

[10]  Liviu Moraru,et al.  Catheter-based impedance measurements in the right atrium for continuously monitoring hematocrit and estimating blood viscosity changes; an in vivo feasibility study in swine. , 2004, Biosensors & bioelectronics.

[11]  H. Meiselman,et al.  Dielectric approach to the investigation of erythrocyte aggregation: I. Experimental basis of the method. , 1999, Biorheology.

[12]  H. Schmid-Schönbein,et al.  Temperature-dependence of red cell aggregation , 1987, Pflügers Archiv.

[13]  J. Grotta,et al.  Whole blood viscosity parameters and cerebral blood flow. , 1982, Stroke.

[14]  小林 充尚 Medical and Biological Engineering : (Abs. No. 525〜534) , 1979 .

[15]  M. Holzer,et al.  Hypothermia for neuroprotection after cardiac arrest: Systematic review and individual patient data meta-analysis , 2005, Critical care medicine.

[16]  M. Woodward,et al.  Associations of blood rheology and interleukin‐6 with cardiovascular risk factors and prevalent cardiovascular disease , 1999, British journal of haematology.

[17]  C. Slager,et al.  Blood Electrical Impedance Closely Matches Whole Blood Viscosity as Parameter of Hemorheology and Inflammation , 2003 .

[18]  E. Sackmann,et al.  Cell-based biosensors for inflammatory agents detection , 2002 .

[19]  R. Ross,et al.  Atherosclerosis is an inflammatory disease. , 1998, American heart journal.

[20]  H. Fricke,et al.  Relation of the Permittivity of Biological Cell Suspensions to Fractional Cell Volume , 1953, Nature.

[21]  S. Chien Clinical hemorheology : applications in cardiovascular and hematological disease, diabetes, surgery, and gynecology , 1987 .

[22]  van de Fn Frans Vosse,et al.  The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90° curved tube , 1999 .

[23]  J. Barbenel,et al.  Clinical Aspects of Blood Viscosity and Cell Deformability , 2012, Springer London.

[24]  M. Aepfelbacher,et al.  Electrical and optical characterization of thrombin-induced permeability of cultured endothelial cell monolayers on semiconductor electrode arrays , 2001 .

[25]  J. Abkowitz,et al.  The microcytic red cell and the anemia of inflammation. , 2009, The New England journal of medicine.

[26]  D. N. Walder,et al.  The effect of increased fibrinogen content on the viscosity of blood. , 1969, Clinical science.

[27]  S. Teerenstra,et al.  Conductivity-Based Hematocrit Measurement During Cardiopulmonary Bypass , 2007, Journal of Clinical Monitoring and Computing.

[28]  Wanchun Tang,et al.  Cerebral cortical microvascular flow during and following cardiopulmonary resuscitation after short duration of cardiac arrest. , 2008, Resuscitation.

[29]  P. Libby,et al.  Inflammation and Atherosclerosis , 2002, Circulation.

[30]  W. Koenig,et al.  The possible role of hemorheology in atherothrombogenesis. , 1992, Atherosclerosis.

[31]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.