Inverse time overcurrent protection scheme for fault location in multi-terminal HVDC

One of the main challenges with HVDC multi-terminal (MTDC) configurations, which are based on voltage source converters (VSC), is the protection system. The dc grids have small series inductances which made them unable to limit the rise time of the DC current when a dc fault occurs. For this reason, the dc fault clearing must be performed very fast in order to limit the effect of the rapid increase of the dc current during dc faults. However, before clearing the line, the fault must be detected and located as soon as possible. The fault location is very challenging using conventional methods that have been used in ac system. This paper investigates a fault location algorithm based on inverse-time overcurrent characteristic. In this algorithm the protection operating time is inversely changed with the current magnitude, so in order to implement it, feed inductor at each cable terminal is needed. A simplified version of CIGRE B4 DC Grid Test System is implemented in PSCAD to test the proposed algorithm.

[1]  Bertrand Raison,et al.  Protection strategy for undersea MTDC grids , 2013, 2013 IEEE Grenoble Conference.

[2]  Zaibin Jiao,et al.  Distance Protection for HVDC Transmission Lines Considering Frequency-Dependent Parameters , 2013, IEEE Transactions on Power Delivery.

[3]  Y. G. Paithankar,et al.  Fundamentals of Power System Protection , 2004, Optimal Coordination of Power Protective Devices with Illustrative Examples.

[4]  Ryszard Kowalik,et al.  Detection, classification and fault location in HV lines using travelling waves , 2012 .

[5]  Justine Descloux Protection contre les courts-circuits des réseaux à courant continu de forte puissance , 2013 .

[6]  Sebastien Dennetiere,et al.  The CIGRE B4 DC Grid Test System , 2013 .

[7]  M. S. Sachdev,et al.  Design, implementation and testing of an artificial neural network based fault direction discriminator for protecting transmission lines , 1995 .

[8]  Xiaohua Li,et al.  Study on the dynamic performance characteristics of HVDC control and protections for the HVDC line fault , 2009, 2009 IEEE Power & Energy Society General Meeting.

[9]  Ali Abur,et al.  Fault location using wavelets , 1998 .

[10]  Dirk Van Hertem,et al.  Multi-terminal VSC HVDC for the European supergrid: Obstacles , 2010 .

[11]  Jin Yang,et al.  Multiterminal DC Wind Farm Collection Grid Internal Fault Analysis and Protection Design , 2010, IEEE Transactions on Power Delivery.

[12]  Zhe Chen,et al.  Design of Protective Inductors for HVDC Transmission Line Within DC Grid Offshore Wind Farms , 2013, IEEE Transactions on Power Delivery.

[13]  O.P. Malik,et al.  Hybrid Traveling Wave/Boundary Protection for Monopolar HVDC Line , 2009, IEEE Transactions on Power Delivery.

[14]  R. Wachal,et al.  Traveling-Wave-Based Line Fault Location in Star-Connected Multiterminal HVDC Systems , 2013, IEEE Transactions on Power Delivery.

[15]  Om P. Malik,et al.  Correction to “Hybrid Traveling Wave/Boundary Protection for Monopolar HVDC Line” [Apr 09 569-578] , 2009 .

[16]  Ibrahim Farhat Fault detection, classification and location in transmission line systems using neural networks , 2003 .

[17]  Jin Yang,et al.  Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables , 2012, IEEE Transactions on Industrial Electronics.

[18]  Denis V. Coury,et al.  Artificial neural network approach to distance protection of transmission lines , 1998 .