Wind energy and natural ventilation potential of a wind catcher in Yazd – Iran (a long-term measurement)

ABSTRACT When designing energy efficient buildings it is useful to study existing climate—responsive building typologies. The wind towers or wind-catchers of Yazd city in Iran are typical examples of such a typology. Although many previous studies have investigated the performance of various types of wind catcher systems, studies based on a long-term real-life measurement can be rarely found. In this study a long-term whole year monitoring campaign on an existing full scale four sided wind catcher in Yazd was carried out in 2014–2015. Three prevailing wind directions were identified and the measured on-site wind speeds were used to estimate the wind induced natural ventilation potential of the tower. A shaft/tower airflow performance index was developed. The monitoring results were compared to the ASHRAE Standard 62:2001 ventilation rate requirement. Results show that the total ventilation rate of the wind tower surpasses the ASHRAE Standard requirements. Furthermore it shows that the shafts are exposed to the prevailing wind directions perform better. For more effective natural ventilation a wind tower with adaptable openings/shafts are proposed.

[1]  Mahmood Yaghoubi,et al.  Wind towers: Measurement and performance , 1991 .

[2]  Mehdi N. Bahadori,et al.  An improved design of wind towers for natural ventilation and passive cooling , 1985 .

[3]  M. Hughes,et al.  Performance analysis. , 2002, Journal of sports sciences.

[4]  H Hamid Montazeri,et al.  Experimental and numerical study on natural ventilation performance of various multi-opening wind catchers , 2011 .

[5]  Azeddine Belhamri,et al.  Performance analysis and improvement of the use of wind tower in hot dry climate , 2011 .

[6]  Ine Wouters,et al.  Performance Assessment of Ancient Wind Catchers - an Experimental and Analytical Study☆ , 2015 .

[7]  Vali Kalantar,et al.  Numerical simulation of cooling performance of wind tower (Baud-Geer) in hot and arid region , 2009 .

[8]  I. Wouters,et al.  Energy Performance Analysis of Solar-wind Catchers Under Hot and Dry Climatic Condition in Iran-Yazd , 2017 .

[9]  Kamaruzzaman Sopian,et al.  Empirical study of a wind-induced natural ventilation tower under hot and humid climatic conditions , 2012 .

[11]  Kamaruzzaman Sopian,et al.  Review of windcatcher technologies , 2012 .

[12]  Mehdi N. Bahadori,et al.  Passive Cooling Systems in Iranian Architecture , 1978, Renewable Energy.

[13]  Paul E. Carrillo,et al.  The Effects of Different , 2016 .

[14]  Bruce Bailey,et al.  Wind resource assessment handbook: Fundamentals for conducting a successful monitoring program , 1997 .

[15]  Mohsen Mazidi,et al.  Experimental investigation of new designs of wind towers , 2008 .

[16]  B. J. Vickery,et al.  Evaluation of pressure coefficients and estimation of air flow rates in buildings employing wind towers , 1986 .

[17]  Hamid Saffari,et al.  Effects of different internal designs of traditional wind towers on their thermal behavior , 2013 .

[18]  N. K. Bansal,et al.  A study of solar chimney assisted wind tower system for natural ventilation in buildings , 1994 .