Multi-dimensional vibration power flow analysis of compressor system mounted in outdoor unit of an air conditioner

Abstract Vibration generated by an excitation source is in general transmitted to a receiver structure through multiple paths, i.e., multiple points in multiple directions. The multi-dimensional vibration transmission path analysis can be effectively accomplished by employing the vibration power approach because the contribution of each path to the total vibration transmission can be readily represented and, furthermore, the vibration power transmitted to the receiver is closely related to the noise radiation from the receiver. The main content of the work presented in this paper is to apply the concept of the vibration power flow to a practical system of multi-dimensional vibration isolation systems for the vibration transmission path analysis. In addition, the role of the vibration power flow will be illustrated as a measure of the vibration transmission onto as well as the resultant noise radiation from the receiver structure. In this paper, the vibration power flow approach is applied to a compressor system mounted in outdoor unit of an air conditioner in order to determine the most dominant transmission path. Then, the frequency characteristics of the vibration power flow to the receiver structure are compared with those of the structural vibration level on and the resultant noise emission from the receiver structure.

[1]  Stephen J. Elliott,et al.  ACTIVE ISOLATION OF STRUCTURAL VIBRATION ON A MULTIPLE-DEGREE-OF-FREEDOM SYSTEM, PART II: EFFECTIVENESS OF ACTIVE CONTROL STRATEGIES , 1997 .

[2]  C. R. Fredö,et al.  Direct measurement of moment mobility: Part I: A theoretical study , 1995 .

[3]  Kwang-joon Kim,et al.  Qualification of Mobility Matrix in Multi-Dimensional Vibration Power Path Analysis(ESDA2002/APM-091) , 2002 .

[4]  K KohY,et al.  複数の加振系の下にある機械支持構造への振動パワー伝達の解析と制御 2 振動パワーの解析と制御手法 , 1996 .

[5]  Barry Gibbs,et al.  Measurement of structure-borne sound emission from resiliently mounted machinesin situ , 1995 .

[6]  Barry Gibbs,et al.  Case Studies of Machine Bases as Structure-borne Sound Sources in Buildings , 1999 .

[7]  M. A. Sanderson VIBRATION ISOLATION: MOMENTS AND ROTATIONS INCLUDED , 1996 .

[8]  M. A. Sanderson Direct measurement of moment mobility: Part II: An experimental study , 1995 .

[9]  Ho Jung Lee,et al.  A Study of the Effects of Rotational Terms in the Power Transmission through Vibration Isolation Systems on Beam-like Structures , 2000 .

[10]  R. G. White,et al.  ANALYSIS AND CONTROL OF VIBRATIONAL POWER TRANSMISSION TO MACHINERY SUPPORTING STRUCTURES SUBJECTED TO A MULTI-EXCITATION SYSTEM, PART II: VIBRATIONAL POWER ANALYSIS AND CONTROL SCHEMES , 1996 .

[11]  Stephen J. Elliott,et al.  ACTIVE ISOLATION OF STRUCTURAL VIBRATION ON A MULTIPLE-DEGREE-OF-FREEDOM SYSTEM, PART I: THE DYNAMICS OF THE SYSTEM , 1997 .

[12]  Scott D. Snyder,et al.  CALCULATION OF VIBRATORY POWER TRANSMISSION FOR USE IN ACTIVE VIBRATION CONTROL , 2000 .