Design and Verification of Novel Low-Cost MR-Guided Small-Animal Stereotactic System

Stereotactic systems have been used for decades to position surgical instruments in important preclinical and clinical studies. We developed and verified a low-cost magnetic-resonance-guided system for accurate preclinical stereotactic operations on small animals. The system consists of both commercially available and custom components, including in-house software written in MATLAB to register coordinate spaces. The software registers target the image-space coordinates from magnetic resonance imaging to the physical space through a rigid-body transform. The transform uses singular value decomposition to determine rotation and translation matrices that are optimal in a least squares sense. Needle positioning and core biopsy studies were performed to verify the accuracy of the system. The needle positioning study demonstrated a sub-millimeter positioning error of 0.294 ± 0.156 mm while using a 26 s gauge Hamilton needle. Biopsy studies demonstrated >94 % success in accessing sub-millimeter stereotactic targets embedded in agarose gel phantoms. These favorable results confirm that despite its relatively low hardware cost (US$18,730) and easy assembly, the system is able to consistently access stereotactic targets on the spatial scale of a small animal.

[1]  J. R. Augustine,et al.  Evolution and rebirth of functional stereotaxy in the subthalamus. , 2013, World neurosurgery.

[2]  Arthur W. Toga,et al.  The informatics of a C57BL/6J mouse brain atlas , 2007, Neuroinformatics.

[3]  J. Frank,et al.  Magnetic resonance imaging of the rhesus monkey brain: use for stereotactic neurosurgery , 2004, Experimental Brain Research.

[4]  D. Peck,et al.  Registration and warping of magnetic resonance images to histological sections. , 1999, Medical physics.

[5]  J L Stone,et al.  Introduction of the human Horsley-Clarke stereotactic frame. , 1996, Neurosurgery.

[6]  J. Gangloff,et al.  Fully Automated Image-Guided Needle Insertion: Application to small animal biopsies , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  K. S. Arun,et al.  Least-Squares Fitting of Two 3-D Point Sets , 1987, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[8]  Hans-Jochen Heinze,et al.  Integration of ultra-high field MRI and histology for connectome based research of brain disorders , 2013, Front. Neuroanat..

[9]  E. Spiegel,et al.  Stereoencephalotomy in thalamotomy and related procedures. , 1952, Journal of the American Medical Association.

[10]  Aaron Fenster,et al.  Design, calibration and evaluation of a robotic needle-positioning system for small animal imaging applications , 2007, Physics in medicine and biology.

[11]  E. Spiegel,et al.  Stereotaxic Apparatus for Operations on the Human Brain. , 1947, Science.

[12]  Bradford A Moffat,et al.  A Methodology for Registration of a Histological Slide and In Vivo MRI Volume Based on Optimizing Mutual Information , 2006, Molecular imaging.

[13]  Steven D Chang,et al.  An Analysis of the Accuracy of the CyberKnife: A Robotic Frameless Stereotactic Radiosurgical System , 2003, Neurosurgery.

[14]  Robert B. Fisher,et al.  Estimating 3-D rigid body transformations: a comparison of four major algorithms , 1997, Machine Vision and Applications.

[15]  Chris Zarow,et al.  Co-registration of in vivo human MRI brain images to postmortem histological microscopic images , 2008 .

[16]  I. Iordachita,et al.  Validation of an image-guided robot system for measurement, biopsy and injection in rodents , 2005, Proceedings of the IEEE 31st Annual Northeast Bioengineering Conference, 2005..

[17]  Takeo Uzuka,et al.  Finite Element Analysis and Experimental Study on Mechanism of Brain Injury Using Brain Model , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  R. Mark Henkelman,et al.  High resolution three-dimensional brain atlas using an average magnetic resonance image of 40 adult C57Bl/6J mice , 2008, NeuroImage.

[19]  R. Leahy,et al.  Digimouse: a 3D whole body mouse atlas from CT and cryosection data , 2007, Physics in medicine and biology.

[20]  Henry Markram,et al.  Computing the size and number of neuronal clusters in local circuits , 2013, Front. Neuroanat..

[21]  T. Haidegger,et al.  Accuracy improvement of a neurosurgical robot system , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[22]  F. Pervin,et al.  Mechanically Similar Gel Simulants for Brain Tissues , 2011 .

[23]  C. Yu,et al.  A Phantom Study of the Geometric Accuracy of Computed Tomographic and Magnetic Resonance Imaging Stereotactic Localization with the Leksell Stereotactic System , 2001, Neurosurgery.

[24]  G. Gillies,et al.  Fluorescence excitation and propagation through brain phantom gelatins: measurements and potential applications , 2010 .

[25]  S. Mori,et al.  Magnetic resonance imaging and micro-computed tomography combined atlas of developing and adult mouse brains for stereotaxic surgery , 2009, Neuroscience.

[26]  David C. Van Essen,et al.  Windows on the brain: the emerging role of atlases and databases in neuroscience , 2002, Current Opinion in Neurobiology.