Ultrasensitive detection in optically dense physiological media: applications to fast reliable biological assays

We present a novel approach for performing fluorescence immunoassay in serum and whole blood using fluorescently labeled anti-rabbit IgG. This approach, which is based on Surface Plasmon-Coupled Emission (SPCE), provides increased sensitivity and substantial background reduction due to exclusive selection of the signal from the fluorophores located near a bio-affinity surface. Effective coupling range for SPCE is only couple of hundred nanometers from the metallic surface. Excited fluorophores outside the coupling layer do not contribute to SPCE, and their free-space emission is not transmitted through the opaque metallic film into the glass substrate. An antigen (rabbit IgG) was adsorbed to a slide covered with a thin silver metal layer, and the SPCE signal from the fluorophore-labeled anti-rabbit antibody, binding to the immobilized antigen, was detected. The effect of the sample matrix (buffer, human serum, or human whole blood) on the end-point immunoassay SPCE signal is discussed. The kinetics of binding could be monitored directly in whole blood or serum. The results showed that human serum and human whole blood attenuate the SPCE end-point signal and the immunoassay kinetic signal only approximately 2- and 3-fold, respectively (compared to buffer), resulting in signals that are easily detectable even in whole blood. The high optical absorption of the hemoglobin can be tolerated because only fluorophores within a couple of hundred nanometers from the metallic film contribute to SPCE. Both glass and plastic slides can be used for SPCE-based assays. We believe that SPCE has the potential of becoming a powerful approach for performing immunoassays based on surface-bound analytes or antibodies for many biomarkers directly in dense samples such as whole blood, without any need for washing steps.

[1]  Kim Pettersson,et al.  A europium chelate for quantitative point-of-care immunoassays using direct surface measurement. , 2003, Analytical chemistry.

[2]  J. Lakowicz,et al.  Directional surface plasmon-coupled emission: application for an immunoassay in whole blood. , 2005, Analytical biochemistry.

[3]  Joseph R Lakowicz,et al.  Radiative decay engineering 3. Surface plasmon-coupled directional emission. , 2004, Analytical biochemistry.

[4]  S. Stroupe,et al.  Antibodies in diagnostic applications. , 2004, Current pharmaceutical biotechnology.

[5]  Joseph R. Lakowicz,et al.  Plastic Versus Glass Support for an Immunoassay on Metal-Coated Surfaces in Optically Dense Samples Utilizing Directional Surface Plasmon-Coupled Emission , 2005, Journal of Fluorescence.

[6]  Zygmunt Gryczynski,et al.  Multi-wavelength immunoassays using surface plasmon-coupled emission. , 2004, Biochemical and biophysical research communications.

[7]  Zygmunt Gryczynski,et al.  Radiative decay engineering 4. Experimental studies of surface plasmon-coupled directional emission. , 2004, Analytical biochemistry.

[8]  D. Chan,et al.  Immunosensors--principles and applications to clinical chemistry. , 2001, Clinica chimica acta; international journal of clinical chemistry.

[9]  Hyuk-Jae Chang,et al.  Development of a point-of-care assay system for high-sensitivity C-reactive protein in whole blood. , 2003, Clinica chimica acta; international journal of clinical chemistry.

[10]  Myoglobin immunoassay utilizing directional surface plasmon-coupled emission. , 2004, Analytical chemistry.

[11]  J. Lakowicz,et al.  Immunoassays based on directional surface plasmon-coupled emission. , 2004, Journal of immunological methods.

[12]  Tuan Vo-Dinh,et al.  Immunosensors: Principles and Applications , 1993 .

[13]  Kim Pettersson,et al.  Quantitative, wide-range, 5-minute point-of-care immunoassay for total human chorionic gonadotropin in whole blood. , 2004, Clinical chemistry.

[14]  Wolfgang Knoll,et al.  Surface-Plasmon Field-Enhanced Fluorescence Spectroscopy , 2000 .