Insertion of wind generators in electrical power systems aimed at active losses reduction using sensitivity analysis

Abstract The study evaluates the electrical power system behaviour when wind turbines are inserted into the power grid. The assessment is made using a sensitivity analysis technique applied to the power flow solution. Unlike the typical algorithms, the sensitivity analysis technique does not require an iterative process, resulting in a fast method with great precision. This proposed method make easy to check the wind turbine behaviour to the changing of wind speed. Initially, the power flow solution is obtained and identified as the base case. When there are perturbations in the generators, the new solution is obtained directly by sensitivity analysis technique. The technique was applied in 34-bus, 70-bus and 126-bus test distribution system. The places chosen to connect the wind turbines were determined by the Incremental Transmission Losses method. The results demonstrate the effectiveness of the methodology. When wind turbines are inserted in the studied systems, active and reactive losses are reduced and voltage profile is improved.

[1]  Claudionor F. Nascimento,et al.  Sensitivity analysis applied to nodal technical losses evaluation in power transmission systems , 2014 .

[2]  Frede Blaabjerg,et al.  Renewable Energy Devices and Systems – Research , 2015 .

[3]  Mauricio B. C. Salles,et al.  Study of Transmission System with Wind Power Control and Optimal Reactive Power Flow , 2014 .

[4]  E.A. DeMeo,et al.  Wind plant integration [wind power plants] , 2005, IEEE Power and Energy Magazine.

[5]  Yan Li,et al.  A Modified Newton-Raphson Power Flow Method Considering Wind Power , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[6]  Poul Ejnar Sørensen,et al.  Reactive power capability of a wind turbine with doubly fed induction generator , 2007 .

[7]  Shesha H. Jayaram,et al.  Capacitor placement in distribution systems using heuristic search strategies , 1997 .

[8]  Edmarcio Antonio Belati,et al.  First-Order Sensitivity Applied in Power Distribution System , 2014 .

[9]  Edmarcio Antonio Belati,et al.  Transmission loss allocation based on optimal power flow and sensitivity analysis , 2008 .

[10]  Henk Polinder,et al.  Dynamic modelling of a wind turbine with doubly fed induction generator , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[11]  Istvan Erlich,et al.  Reactive Power Capability of Wind Turbines Based on Doubly Fed Induction Generators , 2011, IEEE Transactions on Energy Conversion.

[12]  William F. Tinney,et al.  Power Flow Solution by Newton's Method , 1967 .

[13]  A. J. Sguarezi Filho,et al.  Analysis of Transmission Systems With Optimal Power Flow and Dobly-fed Induction Generator , 2015, IEEE Latin America Transactions.

[14]  M. E. Baran,et al.  Optimal capacitor placement on radial distribution systems , 1989 .

[15]  B. E. D. P. Energética Plano Decenal de Expansão de Energia 2026 , 2017 .