Finger Movement Measurements in Arthritic Patients Using Wearable Sensor Enabled Gloves

This paper outlines the initial ideas and results surrounding the development of an accurate hand movement measurement tool. The system consists of a wearable glove measurement tool and a 3D interface. Real time data captured from each glove sensor will be displayed numerically and graphically. It will accurately quantify patients’ flexion, extension, adduction and abduction of finger and thumb joint movements in degrees, maximum and minimum joint range and compare joint range with normal ROM values to determine the degree of deformity of the hand and stiffness of moving finger joints. The system can simultaneously record angles from multiple fingers to detect previously unidentifiable movement patterns. It measures a shift in the position of fingers in relation to the direction of the thumb by measuring web space and recording the minimum, maximum and average values during a number of tests to analyse joint movement and identify areas for joint protection benefit. Data is recorded and used for future com...

[1]  J. Drace,et al.  Evaluation of a fiber optic glove for semi-automated goniometric measurements. , 1990, Journal of rehabilitation research and development.

[2]  Reliability and validity of 3Space Isotrak in the measurement of metacarpophalangeal joint range , 2000 .

[3]  L.K. Simone,et al.  A low cost method to measure finger flexion in individuals with reduced hand and finger range of motion , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  S L Wolf,et al.  Upper extremity joint movement: comparison of two measurement devices. , 1989, Archives of physical medicine and rehabilitation.

[5]  D. Kamper,et al.  Integration of Virtual Reality and an Assistive Device for Hand Rehabilitation Following Stroke , 2007, 2007 IEEE/ICME International Conference on Complex Medical Engineering.

[6]  D.G. Kamper,et al.  Measuring Finger Flexion and Activity Trends over a 25 Hour Period using a Low Cost Wireless Device , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  E. Culham,et al.  Spinal and shoulder complex posture. I: measurement using the 3Space lsotrak , 1993 .

[8]  Israr Ahmed,et al.  Pakistan Sign Language Recognition Using Statistical Template Matching , 2007 .

[9]  H Poizner,et al.  Virtual reality-based post-stroke hand rehabilitation. , 2002, Studies in health technology and informatics.

[10]  G F Hamilton,et al.  Reliability of goniometers in assessing finger joint angle. , 1969, Physical therapy.

[11]  P. Dario,et al.  Evaluation of an instrumented glove for hand-movement acquisition. , 2003, Journal of rehabilitation research and development.

[12]  Margaret A. Finley,et al.  Short-duration robotic therapy in stroke patients with severe upper-limb motor impairment. , 2005, Journal of rehabilitation research and development.