Simultaneous determination of hydroquinone, resorcinol, phenol, m-cresol and p-cresol in untreated air samples using spectrofluorimetry and a custom multiple linear regression-successive projection algorithm.

In this study, a novel, simple, and efficient spectrofluorimetric method to determine directly and simultaneously five phenolic compounds (hydroquinone, resorcinol, phenol, m-cresol and p-cresol) in air samples is presented. For this purpose, variable selection by the successive projections algorithm (SPA) is used in order to obtain simple multiple linear regression (MLR) models based on a small subset of wavelengths. For comparison, partial least square (PLS) regression is also employed in full-spectrum. The concentrations of the calibration matrix ranged from 0.02 to 0.2 mg L(-1) for hydroquinone, from 0.05 to 0.6 mg L(-1) for resorcinol, and from 0.05 to 0.4 mg L(-1) for phenol, m-cresol and p-cresol; incidentally, such ranges are in accordance with the Argentinean environmental legislation. To verify the accuracy of the proposed method a recovery study on real air samples of smoking environment was carried out with satisfactory results (94-104%). The advantage of the proposed method is that it requires only spectrofluorimetric measurements of samples and chemometric modeling for simultaneous determination of five phenols. With it, air is simply sampled and no pre-treatment sample is needed (i.e., separation steps and derivatization reagents are avoided) that means a great saving of time.

[1]  R. Cela,et al.  Quantification of two chromatographic unresolved dichlorophenols using gas chromatography-direct deposition-fourier transform infrared spectrometry and multivariate calibration , 1996 .

[2]  M. C. U. Araújo,et al.  The successive projections algorithm for variable selection in spectroscopic multicomponent analysis , 2001 .

[3]  O. Fatibello‐Filho,et al.  An improved flow system for phenols determination exploiting multicommutation and long pathlength spectrophotometry. , 2004, Talanta.

[4]  Roberto Kawakami Harrop Galvão,et al.  A variable elimination method to improve the parsimony of MLR models using the successive projections algorithm , 2008 .

[5]  D. Cozzolino,et al.  Prediction of phenolic compounds in red wine fermentations by visible and near infrared spectroscopy , 2004 .

[6]  O. Chortyk,et al.  Recent advances in studies on the pyrosynthesis of cigarette smoke constituents , 1987 .

[7]  M. Pistonesi,et al.  Synchronous fluorescence for simultaneous determination of hydroquinone and resorcinol in air samples , 2004, Analytical and bioanalytical chemistry.

[8]  D. Andreescu,et al.  Biosensors designed for environmental and food quality control based on screen-printed graphite electrodes with different configurations , 2002, Analytical and bioanalytical chemistry.

[9]  Richard G. Brereton,et al.  Chemometrics: Data Analysis for the Laboratory and Chemical Plant , 2003 .

[10]  A. Carta,et al.  Determination of phenol and o-cresol by GC/MS in a fatal poisoning case. , 2004, Forensic science international.

[11]  L. Drake,et al.  Where there's smoke. , 2004, Nursing standard (Royal College of Nursing (Great Britain) : 1987).

[12]  Y. Uwano,et al.  Study on tobacco components involved in the pyrolytic generation of selected smoke constituents. , 2005, Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association.

[13]  Tormod Næs,et al.  A user-friendly guide to multivariate calibration and classification , 2002 .

[14]  O. Faroon,et al.  Toxicological profile for phenol , 2008 .

[15]  J. Leffingwell Chemical Constituents of Tobacco Leaf and Differences Among Tobacco Types , 2001 .

[16]  Maria Fernanda Pimentel,et al.  Aspects of the successive projections algorithm for variable selection in multivariate calibration applied to plasma emission spectrometry , 2001 .

[17]  María S. Di Nezio,et al.  Successive projections algorithm improving the multivariate simultaneous direct spectrophotometric determination of five phenolic compounds in sea water , 2007 .

[18]  Adriana G Lista,et al.  Determination of phenol, resorcinol and hydroquinone in air samples by synchronous fluorescence using partial least-squares (PLS). , 2006, Talanta.

[19]  Roberto Kawakami Harrop Galvão,et al.  Cross-validation for the selection of spectral variables using the successive projections algorithm , 2007 .

[20]  N. M. Faber,et al.  Uncertainty estimation and figures of merit for multivariate calibration (IUPAC Technical Report) , 2006 .

[21]  J. Vílchez,et al.  Resolution of phenol, o-cresol, m-cresol and p-cresol mixtures by excitation fluorescence using partial least-squares (PLS) multivariate calibration , 1996 .

[22]  A. Espinosa-Mansilla,et al.  Partial least squares multicomponent fluorimetric determination of fluoroquinolones in human urine samples. , 2004, Talanta.

[23]  M. T. Nielsen,et al.  Tobacco : production, chemistry, and technology , 1999 .