Hydrogel-Forming Microneedle Arrays Can Be Effectively Inserted in Skin by Self-Application: A Pilot Study Centred on Pharmacist Intervention and a Patient Information Leaflet

PurposeTo investigate, for the first time, the influence of pharmacist intervention and the use of a patient information leaflet on self-application of hydrogel-forming microneedle arrays by human volunteers without the aid of an applicator device.MethodsA patient information leaflet was drafted and pharmacist counselling strategy devised. Twenty human volunteers applied 11 × 11 arrays of 400 μm hydrogel-forming microneedle arrays to their own skin following the instructions provided. Skin barrier function disruption was assessed using transepidermal water loss measurements and optical coherence tomography and results compared to those obtained when more experienced researchers applied the microneedles to the volunteers or themselves.ResultsVolunteer self-application of the 400 μm microneedle design resulted in an approximately 30% increase in skin transepidermal water loss, which was not significantly different from that seen with self-application by the more experienced researchers or application to the volunteers. Use of optical coherence tomography showed that self-application of microneedles of the same density (400 μm, 600 μm and 900 μm) led to percentage penetration depths of approximately 75%, 70% and 60%, respectively, though the diameter of the micropores created remained quite constant at approximately 200 μm. Transepidermal water loss progressively increased with increasing height of the applied microneedles and this data, like that for penetration depth, was consistent, regardless of applicant.ConclusionWe have shown that hydrogel-forming microneedle arrays can be successfully and reproducibly applied by human volunteers given appropriate instruction. If these outcomes were able to be extrapolated to the general patient population, then use of bespoke MN applicator devices may not be necessary, thus possibly enhancing patient compliance.

[1]  Ryan F. Donnelly,et al.  Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro , 2009, Pharmaceutical Research.

[2]  He Zhang,et al.  In vitro and in vivo study of thymosin alpha1 biodegradable in situ forming poly(lactide-co-glycolide) implants. , 2010, International journal of pharmaceutics.

[3]  Christopher Allender,et al.  Development of an ex vivo human skin model for intradermal vaccination: tissue viability and Langerhans cell behaviour. , 2009, Vaccine.

[4]  Thakur Raghu Raj Singh,et al.  Hydrogel-Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery , 2012, Advanced functional materials.

[5]  R. Donnelly,et al.  Investigation of solute permeation across hydrogels composed of poly(methyl vinyl ether‐co‐maleic acid) and poly(ethylene glycol) , 2010 .

[6]  D. Das,et al.  Influence of array interspacing on the force required for successful microneedle skin penetration: theoretical and practical approaches. , 2013, Journal of pharmaceutical sciences.

[7]  Haripriya Kalluri,et al.  Formation and Closure of Microchannels in Skin Following Microporation , 2010, Pharmaceutical Research.

[8]  Gideon Kersten,et al.  Needle-free vaccine delivery , 2007, Expert opinion on drug delivery.

[9]  R. Donnelly,et al.  Investigation of solute permeation across poly (ethylene glycol)-crosslinked poly (methyl vinyl ether-co-maleic acid) hydrogels: CRS Copenhagen, July 18-22nd, 2009, Denmark. , 2009 .

[10]  Jung-Hwan Park,et al.  Biodegradable polymer microneedles: fabrication, mechanics and transdermal drug delivery , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  A. Morrissey,et al.  Clinical administration of microneedles: skin puncture, pain and sensation , 2009, Biomedical microdevices.

[12]  Mark R. Prausnitz,et al.  Effect of Microneedle Design on Pain in Human Volunteers , 2008, The Clinical journal of pain.

[13]  Ryan F. Donnelly,et al.  Microneedle-Mediated Transdermal and Intradermal Drug Delivery: Donnelly/Microneedle-Mediated Transdermal and Intradermal Drug Delivery , 2012 .

[14]  H. McCarthy,et al.  Influence of a pore‐forming agent on swelling, network parameters, and permeability of poly(ethylene glycol)‐crosslinked poly(methyl vinyl ether‐co‐maleic acid) hydrogels: Application in transdermal delivery systems , 2012 .

[15]  J. Eyles,et al.  Deliberations about deliberative methods: issues in the design and evaluation of public participation processes. , 2003, Social science & medicine.

[16]  James C. Birchall,et al.  Microneedles in Clinical Practice–An Exploratory Study Into the Opinions of Healthcare Professionals and the Public , 2010, Pharmaceutical Research.

[17]  A. Kissenpfennig,et al.  Microneedle-mediated vaccine delivery: Harnessing cutaneous immunobiology to improve efficacy , 2012, Expert opinion on drug delivery.

[18]  H. Kalluri,et al.  Characterization of Microchannels Created by Metal Microneedles: Formation and Closure , 2011, AAPS Journal.

[19]  Thakur Raghu Raj Singh,et al.  Optical coherence tomography is a valuable tool in the study of the effects of microneedle geometry on skin penetration characteristics and in-skin dissolution. , 2010, Journal of controlled release : official journal of the Controlled Release Society.

[20]  Conor O'Mahony,et al.  Hydrogel-forming microneedle arrays exhibit antimicrobial properties: potential for enhanced patient safety. , 2013, International journal of pharmaceutics.

[21]  Conor O'Mahony,et al.  Processing difficulties and instability of carbohydrate microneedle arrays , 2009, Drug development and industrial pharmacy.

[22]  Mark R Prausnitz,et al.  Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force. , 2004, Journal of biomechanics.

[23]  Ryan F. Donnelly,et al.  Design, Optimization and Characterisation of Polymeric Microneedle Arrays Prepared by a Novel Laser-Based Micromoulding Technique , 2010, Pharmaceutical Research.

[24]  Biana Godin,et al.  Transdermal skin delivery: predictions for humans from in vivo, ex vivo and animal models. , 2007, Advanced drug delivery reviews.

[25]  Ryan F Donnelly,et al.  Review of patents on microneedle applicators. , 2011, Recent patents on drug delivery & formulation.

[26]  Ryan F. Donnelly,et al.  Microneedle-mediated Transdermal and Intradermal Drug Delivery , 2012 .

[27]  M. Garland,et al.  Laser-Engineered Dissolving Microneedle Arrays for Transdermal Macromolecular Drug Delivery , 2011, Pharmaceutical Research.

[28]  Maelíosa T. C. McCrudden,et al.  Microneedles for intradermal and transdermal drug delivery. , 2013, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[29]  J. Bouwstra,et al.  In vivo assessment of safety of microneedle arrays in human skin. , 2008, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[30]  Zhang Yong,et al.  Super-short solid silicon microneedles for transdermal drug delivery applications , 2010 .

[31]  Jung-Hwan Park,et al.  Microneedles for drug and vaccine delivery. , 2012, Advanced drug delivery reviews.

[32]  Ryan F Donnelly,et al.  Effects of microneedle length, density, insertion time and multiple applications on human skin barrier function: assessments by transepidermal water loss. , 2010, Toxicology in vitro : an international journal published in association with BIBRA.