Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne.

INTRODUCTION The use of reciprocating movement was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison with continuous rotation. Recently 2 new brands of NiTi files have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these 2 files, Reciproc and WaveOne. METHODS Cyclic fatigue test with a simultaneous pecking motion was performed with the instrument (n = 10 each) operating in the recommended reciprocation motion until fracture for the Reciproc R25 and WaveOne Primary files. ProTaper F2 was tested in continuous rotation to serve as a control for comparison. The number of cycles to fracture (NCF) was determined by measuring the time to fracture. The length of the fragment was measured and the fracture surface was examined by using scanning electron microscopy. Torsional strength was measured by using a torsiometer after fixing the apical 5 mm of the instrument rigidly. Statistical analysis was performed by using one-way analysis of variance. RESULTS The results showed that Reciproc had a higher NCF and WaveOne had a higher torsional resistance than the others. Both reciprocating files demonstrated significantly higher cyclic fatigue and torsional resistances than ProTaper (P < .05). The fractographic analysis showed typical features of cyclic fatigue and torsional failure for all instruments. CONCLUSIONS The 2 brands of NiTi file for use with a reciprocation motion seem to have superior mechanical properties.

[1]  Edgar Schäfer,et al.  Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study. , 2004, Journal of endodontics.

[2]  G Yared,et al.  Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. , 2008, International endodontic journal.

[3]  Libor Kovarik,et al.  Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments. , 2009, Journal of endodontics.

[4]  Bock Hur,et al.  Dynamic torsional resistance of nickel-titanium rotary instruments. , 2010, Journal of endodontics.

[5]  H. Steiman,et al.  Evaluation of single-use rotary nickel-titanium instruments. , 2003, Journal of endodontics.

[6]  H H Messer,et al.  A comparison of stainless steel hand and rotary nickel-titanium instrumentation using a silicone impression technique. , 2002, Australian dental journal.

[7]  Ove A Peters,et al.  Current challenges and concepts in the preparation of root canal systems: a review. , 2004, Journal of endodontics.

[8]  Yufeng Zheng,et al.  Influence of cross-sectional design and dimension on mechanical behavior of nickel-titanium instruments under torsion and bending: a numerical analysis. , 2010, Journal of endodontics.

[9]  G. Cantatore,et al.  Alternating versus continuous rotation: a comparative study of the effect on instrument life. , 2010, Journal of endodontics.

[10]  J. Radford,et al.  Instrument fracture: mechanisms, removal of fragments, and clinical outcomes , 2010, BDJ.

[11]  K. Kum,et al.  Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals. , 2010, Journal of endodontics.

[12]  Neville W. Sachs Understanding the surface features of fatigue fractures: How they describe the failure cause and the failure history , 2005 .

[13]  S. W. Schneider,et al.  A comparison of canal preparations in straight and curved root canals. , 1971, Oral surgery, oral medicine, and oral pathology.

[14]  G De-Deus,et al.  Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. , 2010, International endodontic journal.

[15]  Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. , 2001, Journal of endodontics.

[16]  Bock Hur,et al.  Torsional strength and toughness of nickel-titanium rotary files. , 2011, Journal of endodontics.

[17]  Gianluca Gambarini,et al.  A review of cyclic fatigue testing of nickel-titanium rotary instruments. , 2009, Journal of endodontics.

[18]  J. P. Pruett,et al.  Cyclic fatigue testing of nickel-titanium endodontic instruments. , 1997, Journal of endodontics.

[19]  B M Kim,et al.  Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals. , 2009, International endodontic journal.

[20]  A. Versluis,et al.  Comparison of torsional stiffness of nickel-titanium rotary files with different geometric characteristics. , 2011, Journal of endodontics.

[21]  Gianluca Gambarini,et al.  Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. , 2008, Journal of endodontics.

[22]  B. Sattapan,et al.  Defects in rotary nickel-titanium files after clinical use. , 2000, Journal of endodontics.

[23]  Byung-Min Kim,et al.  Correlation between experimental cyclic fatigue resistance and numerical stress analysis for nickel-titanium rotary files. , 2011, Journal of endodontics.