Label-free protein assay based on a nanomechanical cantilever array

We demonstrate continuous label-free detection of two cardiac biomarker proteins (creatin kinase and myoglobin) using an array of microfabricated cantilevers functionalized with covalently anchored anti-creatin kinase and anti-myoglobin antibodies. This method allows biomarker proteins to be detected via measurement of surface stress generated by antigen–antibody molecular recognition. Reference cantilevers are used to eliminate thermal drifts, undesired chemical reactions and turbulences from injections of liquids by calculating differential deflection signals with respect to sensor cantilevers. The sensitivity achieved for myoglobin detection is below 20 µg ml−1. Both myoglobin and creatin kinase could be detected independently using cantilevers functionalized with the corresponding antibodies, in unspecific protein background. This approach permits the use of up to seven different antigen–antibody reactions simultaneously, including an additional thermomechanical and chemical in situ reference. Applications lie in the field of early and rapid diagnosis of acute myocardial infarction.

[1]  A. Plückthun Mono‐ and Bivalent Antibody Fragments Produced in Escherichia coli: Engineering, Folding and Antigen Binding , 1992, Immunological reviews.

[2]  D Wybenga,et al.  Cardiac-specific troponin I levels to predict the risk of mortality in patients with acute coronary syndromes. , 1996, The New England journal of medicine.

[3]  M. Hegner,et al.  Covalent immobilization of native biomolecules onto Au(111) via N-hydroxysuccinimide ester functionalized self-assembled monolayers for scanning probe microscopy. , 1996, Biophysical journal.

[4]  J. Therasse,et al.  Validation of antibody-based recognition by piezoelectric transducers through electroacoustic admittance analysis. , 1998, Biosensors & bioelectronics.

[5]  John M. Walker,et al.  Protein protocols on CD-ROM , 1998 .

[6]  R. Valdes,et al.  Standardizing utilization of biomarkers in diagnosis and management of acute cardiac syndromes. , 1999, Clinica chimica acta; international journal of clinical chemistry.

[7]  Ute Drechsler,et al.  Highly parallel data storage system based on scanning probe arrays , 2000 .

[8]  H. Rothuizen,et al.  Translating biomolecular recognition into nanomechanics. , 2000, Science.

[9]  Eorge,et al.  CARDIAC-SPECIFIC TROPONIN I LEVELS TO PREDICT THE RISK OF MORTALITY IN PATIENTS WITH ACUTE CORONARY SYNDROMES , 2000 .

[10]  C. Hamm,et al.  Cardiac biomarkers for rapid evaluation of chest pain. , 2001, Circulation.

[11]  M. Panteghini Recent approaches in standardization of cardiac markers. , 2001, Clinica chimica acta; international journal of clinical chemistry.

[12]  S. Rockson,et al.  Feasibility and Reliability of Rapid Diagnosis of Myocardial Infarction , 2001, The American journal of the medical sciences.

[13]  T. Thundat,et al.  Bioassay of prostate-specific antigen (PSA) using microcantilevers , 2001, Nature Biotechnology.

[14]  R. Corn,et al.  Surface plasmon resonance imaging measurements of DNA and RNA hybridization adsorption onto DNA microarrays. , 2001, Analytical chemistry.

[15]  C. Herzog,et al.  Cardiac Biomarkers in the New Millennium , 2001, Seminars in dialysis.

[16]  John M. Walker Protein protocols on CD-ROM : version 2.0 , 2002 .

[17]  D Leech,et al.  Characterisation of an antibody coated microcantilever as a potential immuno-based biosensor. , 2002, Biosensors & bioelectronics.

[18]  M. Esashi,et al.  Fabrication of thermal microprobes with a sub-100 nm metal-to-metal junction , 2002 .

[19]  Ernst Meyer,et al.  Nanomechanics from atomic resolution to molecular recognition based on atomic force microscopy technology , 2002 .

[20]  H. Lang,et al.  Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array , 2002, Proceedings of the National Academy of Sciences of the United States of America.