Experimental Study of a TET System for Implantable Biomedical Devices

Time-varying magnetic fields can be used to transfer power across the skin to drive implantable biomedical devices without the use of percutaneous wires. However, the main challenges of a transcutanoues energy transfer (TET) system are the temperature rise caused by power loss in the implanted circuitry and the changes in positioning between the external and internal coils due to fitting and changes in posture. This study presents a TET system with a closed-loop frequency-based power regulation method to deliver the right amount of power to the load under variable coil coupling conditions. After implanting a TET system into adult sheep, the temperature rise in the internal and external coils of a TET system was measured for power delivery in the range of 5 W to 15 W. The sheep was housed in a temperature controlled (16 plusmn1degC, humidity 50plusmn10%) room, in accordance with the standard protocols implemented at the University of Auckland for sheep studies. A power-loss analysis for the overall system was performed. The system was capable of regulating power for axially aligned separations of up to 16 mm. The maximum power efficiency of the overall system was 82.1% and a maximum temperature rise of 2.7degC was observed on the implanted secondary coil.

[1]  T. Myers,et al.  Continuous flow pumps and total artificial hearts: management issues. , 2003, The Annals of thoracic surgery.

[2]  Chih-Ming Tsai,et al.  Design of wireless transcutaneous energy transmission system for totally artificial hearts , 2000, IEEE APCCAS 2000. 2000 IEEE Asia-Pacific Conference on Circuits and Systems. Electronic Communication Systems. (Cat. No.00EX394).

[3]  Wentai Liu,et al.  A closed loop transcutaneous power transfer system for implantable devices with enhanced stability , 2004, 2004 IEEE International Symposium on Circuits and Systems (IEEE Cat. No.04CH37512).

[4]  M. Bartoli,et al.  Modeling Litz-wire winding losses in high-frequency power inductors , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[5]  Aiguo Patrick Hu,et al.  A Frequency Control Method for Regulating Wireless Power to Implantable Devices , 2008, IEEE Transactions on Biomedical Circuits and Systems.

[6]  B.H. Cho,et al.  Design of a transcutaneous energy transmission system using a series resonant converter , 1990, 21st Annual IEEE Conference on Power Electronics Specialists.

[7]  Adrian F Hernandez,et al.  Implantable left ventricular assist devices: new hope for patients with end-stage heart failure. , 2006, North Carolina medical journal.

[8]  G. T. Martin,et al.  Transport lattice models of heat transport in skin with spatially heterogeneous, temperature-dependent perfusion , 2004, Biomedical engineering online.

[9]  A.P. Hu,et al.  Wireless Power Supply for Implantable Biomedical Device Based on Primary Input Voltage Regulation , 2007, 2007 2nd IEEE Conference on Industrial Electronics and Applications.

[10]  T Mussivand,et al.  Transcutaneous energy transfer system performance evaluation. , 2008, Artificial organs.

[11]  D. Budgett,et al.  Experimental thermal study of a TET system for implantable biomedical devices , 2008, 2008 IEEE Biomedical Circuits and Systems Conference.

[12]  F. Lupo,et al.  High power electromagnetic energy transfer for totally implanted devices , 1970 .

[13]  Aiguo Patrick Hu,et al.  Magnetic Coupling Analysis of a TET Power Delivery System , 2008, BIODEVICES.

[14]  G. Lazzi,et al.  Thermal effects of bioimplants , 2005, IEEE Engineering in Medicine and Biology Magazine.

[15]  Rahul Sarpeshkar,et al.  Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[16]  R Puers,et al.  Recent progress on transcutaneous energy transfer for total artificial heart systems. , 2001, Artificial organs.

[17]  A. Berson Magnetic control and powering of surgically implanted instrumentation , 1983, IEEE Transactions on Magnetics.

[18]  Aiguo Patrick Hu,et al.  Selected resonant converters for IPT power supplies , 2001 .

[19]  H. Matsuki,et al.  Simulations of temperature rise on transcutaneous energy transmission by non-contact energy transmitting coils , 1993 .