Performance of distance relays in presence of IPFC

In this paper, the analytical and simulation results of the application of distance relay for the protection of transmission line incorporating Inter-line Power Flow Controller (IPFC) are presented. Firstly a detailed model of the IPFC and its control is proposed and then it is integrated into the 8-bus transmission system for the purposes of accurately simulating the fault transients. The simulation results show the impact of different operational mode of IPFC on the performance of a distance protection relays.

[1]  Hossein Askarian Abyaneh,et al.  A new comprehensive genetic algorithm method for optimal overcurrent relays coordination , 2008 .

[2]  Mojtaba Khederzadeh The impact of FACTS device on digital multifunctional protective relays , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[3]  T. Hlibka,et al.  Fundamental basis for distance relaying with symmetrical components , 1977, IEEE Transactions on Power Apparatus and Systems.

[4]  Ganapati Panda,et al.  Adaptive relay setting for flexible AC transmission systems (FACTS) , 2000 .

[5]  T.S. Sidhu,et al.  Series compensated line protection enhancement by modified pilot relaying schemes , 2006, IEEE Transactions on Power Delivery.

[6]  Laszlo Gyugyi,et al.  Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems , 1999 .

[7]  T.S. Sidhu,et al.  Performance of distance relays on shunt-FACTS compensated transmission lines , 2005, IEEE Transactions on Power Delivery.

[8]  B. Vahidi,et al.  Power System Stabilization Improvement by Using PSO-based UPFC , 2008, 2008 Joint International Conference on Power System Technology and IEEE Power India Conference.

[9]  Rajiv K. Varma,et al.  Thyristor-Based Facts Controllers for Electrical Transmission Systems , 2002 .

[10]  D. L. Waikar,et al.  Fault impedance estimation algorithm for digital distance relaying , 1994 .

[11]  M. Fotuhi-Firuzabad,et al.  Composite System Reliability Assessment Incorporating an Interline Power-Flow Controller , 2008, IEEE Transactions on Power Delivery.

[12]  T.S. Sidhu,et al.  Performance Comparison of Distance Protection Schemes for Shunt-FACTS Compensated Transmission Lines , 2007, IEEE Transactions on Power Delivery.

[13]  Yin Xianggen,et al.  The impact of TCSC on distance protection relay , 1998, POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151).

[14]  G. Joos,et al.  Operation of Impedance Protection Relays with the STATCOm , 2002, IEEE Power Engineering Review.

[15]  R.K. Aggarwal,et al.  Performance evaluation of a distance relay as applied to a transmission system with UPFC , 2006, IEEE Transactions on Power Delivery.

[16]  K. K. Sen,et al.  The interline power flow controller concept: a new approach to power flow management in transmission systems , 1999 .