Performance of near surface mounted glass fiber reinforced polymer bars in concrete

Near surface mounted fiber reinforced polymer reinforcement has become very popular method in strengthening of reinforced concrete structures. The major problem that accompanied the near surface mounted technique is the bond between fiber-reinforced polymers and concrete that corresponds to the stress transfer from concrete into fiber-reinforced polymers. This article presents the test results of pullout tests of near surface mounted glass fiber reinforced polymer bars to investigate the effect of different parameters on the bond performance of this strengthening technique. The test parameters include: adhesive type, groove size, bonded length, environmental condition, and concrete strength. A total of 40 near surface mounted–fiber-reinforced polymer bars, installed in C-shaped concrete blocks, were constructed and tested to failure. Five types of cement and epoxy-based adhesives were used. Two groove sizes and three bonded lengths were also investigated. Normal and high strength concrete were also used. In addition, the effect of two harsh environmental conditions on the performance of the strengthening system was also investigated. The results are presented in terms of pullout loads, free end slip, and mode of failure.

[1]  L. Lorenzis,et al.  Near-surface mounted FRP reinforcement: An emerging technique for strengthening structures , 2007 .

[2]  Emidio Nigro,et al.  Bond behavior of FRP NSM systems in concrete elements , 2012 .

[3]  Antonio Nanni,et al.  Bond between Near-Surface Mounted Fiber-Reinforced Polymer Rods and Concrete in Structural Strengthening , 2002 .

[4]  J. Barros,et al.  Efficacy of CFRP-based techniques for the flexural and shear strengthening of concrete beams , 2007 .

[5]  J. Yost,et al.  FLEXURAL BEHAVIOR OF CONCRETE BEAMS STRENGTHENED WITH NEAR-SURFACE-MOUNTED CFRP STRIPS , 2007 .

[6]  Francesco Micelli,et al.  ENVIRONMENTAL EFFECTS ON RC BEAMS WITH NEAR SURFACE MOUNTED FRP RODS , 2003 .

[7]  Xiang Yan,et al.  CHARACTERIZATION OF CFRP RODS USED AS NEAR-SURFACE MOUNTED REINFORCEMENT , 2000 .

[8]  Laura De Lorenzis,et al.  A modified pull-out test for bond of near-surface mounted FRP rods in concrete , 2002 .

[9]  H. M. Tanarslan,et al.  The effects of NSM CFRP reinforcements for improving the shear capacity of RC beams , 2011 .

[10]  Laura De Lorenzis,et al.  Strengthening of RC structures with near surface mounted FRP rods , 2000 .

[11]  Antonio Nanni,et al.  Shear Strengthening of Reinforced Concrete Beams with Near-Surface Mounted Fiber-Reinforced Polymer Rods , 2001 .

[12]  Laura De Lorenzis,et al.  Behavior and capacity of RC beams strengthened in shear with NSM FRP reinforcement , 2009 .

[13]  Bo Wang,et al.  Debonding Failures of RC Beams Strengthened with Near Surface Mounted CFRP Strips , 2006 .

[14]  Antonio Nanni,et al.  Characterization of FRP Rods as Near-Surface Mounted Reinforcement , 2001 .

[15]  Laura De Lorenzis,et al.  Modeling of debonding failure for RC beams strengthened in shear with NSM FRP reinforcement , 2009 .

[16]  Brahim Benmokrane,et al.  Bond Performance of Near-Surface-Mounted FRP Bars , 2011 .

[17]  Deric J. Oehlers,et al.  IC debonding resistance of groups of FRP NSM strips in reinforced concrete beams , 2008 .

[18]  S. Rizkalla,et al.  Bond Mechanism of Near-Surface-MountedFiber-Reinforced Polymer Bars for FlexuralStrengthening of Concrete Structures , 2004 .

[19]  J. Barros,et al.  Near surface mounted CFRP laminates for shear strengthening of concrete beams , 2006 .

[20]  F. Ceroni Experimental performances of RC beams strengthened with FRP materials , 2010 .

[21]  Antonio Nanni,et al.  Shear Strengthening of a PC Bridge Girder with NSM CFRP Rectangular Bars , 2004 .

[22]  Emidio Nigro,et al.  Bond Efficiency of EBR and NSM FRP Systems for Strengthening Concrete Members , 2011 .

[23]  Albino J.P. Da Cunha,et al.  Strengthening of reinforced concrete beams , 1989 .

[24]  Abid Nadeem,et al.  Flexural strengthening of reinforced lightweight polystyrene aggregate concrete beams with near-surface mounted GFRP bars , 2006 .

[25]  Giorgio Monti,et al.  Three dimensional mechanical model for simulating the NSM FRP strips shear strength contribution to RC beams , 2009 .