Using silicon diodes for detecting the liquid-vapor interface in hydrogen
暂无分享,去创建一个
Tests were performed using commercially available silicon diode temperature sensors to detect the location of the liquid-vapor interface in hydrogen during ground test programs. Results show that by increasing the current into the sensor, silicon diodes can be used as liquid level point sensors. After cycling the sensors from liquid to vapor several times, it was found that with a 30 mA (milliamps) input current, the sensors respond within 2 seconds by measuring a large voltage difference when transitioning from liquid to vapor across the interface. Nearly instantaneous response resulted during a transition form vapor to liquid. Detailed here are test procedures, experimental results, and guidelines for applying this information to other test facilities.
[1] Robert D. McCarty,et al. Hydrogen technology survey: Thermophysical properties , 1975 .
[2] R. O. Voth,et al. Liquid-vapour surface sensors for liquid nitrogen and hydrogen , 1992 .
[3] R. J. Stochl,et al. Temperature and liquid-level sensor for liquid-hydrogen pressurization and expulsion studies , 1968 .