Active Control of Noise Transmitted through Ventilation Openings of the Machinery Room of Refrigerator
暂无分享,去创建一个
The active control of noise generated by the compressor and transmitted out of the machine room through the windows is implemented based on the FIR filter. The machine room contains most of noise sources of electric home appliances, air-conditioners and refrigerators, for example. To actively reduce the noise from the machinery room. In this paper, the transfer function of the controller for minimization of the acoustic power transmitted through the windows is mathematically formulated. The transfer functions required for implementation of the active controller are the measured. The measurements are conducted in this initial stage under the operation of the compressor with no load. For improvement of the reliability of the transfer function of the compressor to the acoustic power, additional operational measurements are performed. The real time controller is implemented based on the FIR filter using the measured transfer functions and the performance of the active controller is estimated. Control performance is measured about 3 dB ~ 10 dB in reduction of the sound power at the peaks of the compressor noise.
[1] 정의봉,et al. 증발기 구조 개선을 통한 냉매 소음 저감 , 2009 .
[2] Philip A. Nelson,et al. Active Control of Sound , 1990 .
[3] Hyung-Suk Han,et al. Reduction of Refrigerant-induced Noise of the Refrigerator by Modification of the Evaporator Inlet Pipe , 2009 .
[4] 김태훈,et al. FIR 필터를 이용한 인클로저 환기구를 통해 투과되는 소음의 능동제어 , 2015 .