Automatic Segmentation of Corneal Microlayers on Optical Coherence Tomography Images

Purpose To propose automatic segmentation algorithm (AUS) for corneal microlayers on optical coherence tomography (OCT) images. Methods Eighty-two corneal OCT scans were obtained from 45 patients with normal and abnormal corneas. Three testing data sets totaling 75 OCT images were randomly selected. Initially, corneal epithelium and endothelium microlayers are estimated using a corneal mask and locally refined to obtain final segmentation. Flat-epithelium and flat-endothelium images are obtained and vertically projected to locate inner corneal microlayers. Inner microlayers are estimated by translating epithelium and endothelium microlayers to detected locations then refined to obtain final segmentation. Images were segmented by trained manual operators (TMOs) and by the algorithm to assess repeatability (i.e., intraoperator error), reproducibility (i.e., interoperator and segmentation errors), and running time. A random masked subjective test was conducted by corneal specialists to subjectively grade the segmentation algorithm. Results Compared with the TMOs, the AUS had significantly less mean intraoperator error (0.53 ± 1.80 vs. 2.32 ± 2.39 pixels; P < 0.0001), it had significantly different mean segmentation error (3.44 ± 3.46 vs. 2.93 ± 3.02 pixels; P < 0.0001), and it had significantly less running time per image (0.19 ± 0.07 vs. 193.95 ± 194.53 seconds; P < 0.0001). The AUS had insignificant subjective grading for microlayer-segmentation grading (4.94 ± 0.32 vs. 4.96 ± 0.24; P = 0.5081), but it had significant subjective grading for regional-segmentation grading (4.96 ± 0.26 vs. 4.79 ± 0.60; P = 0.025). Conclusions The AUS can reproduce the manual segmentation of corneal microlayers with comparable accuracy in almost real-time and with significantly better repeatability. Translational Relevance The AUS can be useful in clinical settings and can aid the diagnosis of corneal diseases by measuring thickness of segmented corneal microlayers.

[1]  Hossein Rabbani,et al.  An Automatic Algorithm for Segmentation of the Boundaries of Corneal Layers in Optical Coherence Tomography Images using Gaussian Mixture Model , 2014, Journal of medical signals and sensors.

[2]  Sander R. Dubovy,et al.  Diagnosis of ocular surface lesions using ultra-high-resolution optical coherence tomography. , 2013, Ophthalmology.

[3]  Mona K. Garvin,et al.  3D graph-based automated segmentation of corneal layers in anterior-segment optical coherence tomography images of mice , 2014, Medical Imaging.

[4]  Yankui Sun,et al.  AUTOMATED EXTRACTION OF THE INNER CONTOUR OF THE ANTERIOR CHAMBER USING OPTICAL COHERENCE TOMOGRAPHY IMAGES , 2012 .

[5]  Yalin Zheng,et al.  Reconstruction of 3D surface maps from anterior segment optical coherence tomography images using graph theory and genetic algorithms , 2016, Biomed. Signal Process. Control..

[6]  S. Kaufman,et al.  Clinical corneal confocal microscopy. , 2006, Survey of ophthalmology.

[7]  Joseph A. Izatt,et al.  Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming , 2011, Biomedical optics express.

[8]  Guanglin Li,et al.  A Novel Technique for Robust and Fast Segmentation of Corneal Layer Interfaces Based on Spectral-Domain Optical Coherence Tomography Imaging , 2017, IEEE Access.

[9]  Shuliang Jiao,et al.  Use of ultra-high-resolution optical coherence tomography to detect in vivo characteristics of Descemet's membrane in Fuchs' dystrophy. , 2010, Ophthalmology.

[10]  Yalin Zheng,et al.  Fast segmentation of anterior segment optical coherence tomography images using graph cut , 2015, Eye and Vision.

[11]  Barry R. Masters,et al.  Digital Image Processing, Third Edition , 2009 .

[12]  Yan Li,et al.  Segmentation of 830- and 1310-nm LASIK corneal optical coherence tomography images , 2002, SPIE Medical Imaging.

[13]  L. Schmetterer,et al.  Ultrahigh-resolution OCT imaging of the human cornea. , 2017, Biomedical optics express.

[14]  Sander R. Dubovy,et al.  Descemet Membrane Thickening as a Sign for the Diagnosis of Corneal Graft Rejection: An Ex Vivo Study , 2017, Cornea.

[15]  T. Tsuru,et al.  Corneal Wound Healing from the Perspective of Keratoplasty Specimens With Special Reference to the Function of the Bowman Layer and Descemet Membrane , 2007, Cornea.

[16]  M. Coroneo,et al.  In vivo confocal microscopy of the human cornea , 2003, The British journal of ophthalmology.

[17]  David A. Clausi,et al.  Automated 3D Reconstruction and Segmentation from Optical Coherence Tomography , 2010, ECCV.

[18]  David A. Clausi,et al.  A Novel Algorithm for Extraction of the Layers of the Cornea , 2009, 2009 Canadian Conference on Computer and Robot Vision.

[19]  Yalin Zheng,et al.  Automatic segmentation of anterior segment optical coherence tomography images , 2013, Journal of biomedical optics.

[20]  Robert C. Bolles,et al.  Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography , 1981, CACM.

[21]  Dexi Zhu,et al.  Ultra-high resolution optical coherence tomography for imaging the anterior segment of the eye. , 2011, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[22]  Terry Kim,et al.  Anatomy and physiology of the cornea , 2011, Journal of cataract and refractive surgery.

[23]  Mohamed Abou Shousha,et al.  Diagnosis and management of conjunctival and corneal intraepithelial neoplasia using ultra high-resolution optical coherence tomography. , 2011, Ophthalmology.

[24]  William J Feuer,et al.  The use of Bowman's layer vertical topographic thickness map in the diagnosis of keratoconus. , 2014, Ophthalmology.

[25]  Wolfgang Drexler,et al.  Optical Coherence Tomography (OCT) in ophthalmology: introduction. , 2009, Optics express.

[26]  William J Feuer,et al.  In Vivo Characteristics of Corneal Endothelium/Descemet Membrane Complex for the Diagnosis of Corneal Graft Rejection. , 2017, American journal of ophthalmology.

[27]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[28]  Sander R. Dubovy,et al.  Topographic thickness of Bowman's layer determined by ultra-high resolution spectral domain-optical coherence tomography. , 2011, Investigative ophthalmology & visual science.