Post-occupancy evaluation of a university student cafeteria

ABSTRACT This paper presents the findings of an indicative post-occupancy evaluation (POE) of the major technical and functional performance elements of the main student cafeteria at the campus of King Fahd University of Petroleum and Minerals (KFUPM), Dhahran, Saudi Arabia. Published literature has been analyzed to review the performance requirements of cafeterias and restaurant facilities. The research implements multiple data collection methods, including a walk-through inspection to identify the extent of deficiencies found in the building; a focus group discussion with a sample of 10 frequent users of the student cafeteria to obtain their qualitative feedback on the quality of the building and a questionnaire survey to quantify users' perception and level of satisfaction with the quality of the built environment. The findings obtained were analyzed and reported to indicate the main failures and successes of the facility's performance, and describe the degree of users' satisfaction. A series of recommendations to improve the performance of the student cafeteria were developed. The paper provides a systematic approach for evaluating the technical and functional performance of existing cafeterias and restaurant facilities. It is of practical value to planning, design professionals, building services' engineers and facilities managers responsible for the design and operation of these facilities.

[1]  Kemi Adeyeye,et al.  The impact of design decisions on post occupancy processes in school buildings , 2013 .

[2]  Bram Wauters,et al.  The added value of facilities management: benchmarking work processes , 2005 .

[3]  Michael Pitt,et al.  Assessing post occupancy evaluation in higher education facilities , 2010 .

[4]  Wolfgang F. E. Preiser Building Performance Assessment—From POE to BPE, A Personal Perspective , 2005 .

[5]  Adrian Leaman,et al.  Building evaluation: practice and principles , 2010 .

[6]  C. Lebo,et al.  Restaurant noise, hearing loss, and hearing aids. , 1994, The Western journal of medicine.

[7]  Richard Wener,et al.  Post occupancy evaluation , 2002 .

[8]  M G Apte,et al.  Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. , 2003, Indoor air.

[9]  University Foodservice in Hong Kong , 1998 .

[10]  David Adler,et al.  New Metric Handbook: Planning and design data , 1997 .

[11]  Mei-yung Leung,et al.  Enhancement of classroom facilities of primary schools and its impact on learning behaviors of students , 2005 .

[12]  M. O'Neill,et al.  A Six Sigma quality approach to workplace evaluation , 2005 .

[13]  Joseph De Chiara,et al.  Time-saver standards for building types , 1973 .

[14]  Nusser A. Raajpoot TANGSERV: a multiple item scale for measuring tangible quality in foodservice industry , 2002 .

[15]  Lela Gramling,et al.  FOODSERVICE MANAGEMENT AND ITS IMPACT ON COLLEGE OPERATIONS: A BUSINESS ANTHROPOLOGICAL CASE STUDY , 2005 .

[16]  Mohammad A. Hassanain,et al.  Fire safety evaluation of restaurant facilities , 2005 .

[17]  Mohammad A. Hassanain,et al.  Post‐occupancy evaluation of academic and research library facilities , 2006 .

[18]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[19]  David Littlefield,et al.  Metric Handbook: Planning and Design Data , 2011 .

[20]  Kristian Widén,et al.  Managing the needs of end‐users in the design and delivery of construction projects , 2010 .

[21]  Giuliano Dall’O’,et al.  Green Energy Audit of Buildings , 2013 .

[22]  Wolfgang F. E. Preiser Continuous quality improvement through post‐occupancy evaluation feedback , 2003 .

[23]  Abdul-Wahid A. Saif,et al.  A framework for quality evaluation of university housing facilities , 2010 .

[24]  S. Turpin‐Brooks,et al.  The development of robust methods of post occupancy evaluation , 2006 .

[25]  Tyler J. Sanders Dining in daylight : a study of the use of daylight in a faculty dining hall in Muncie, IN : programming, strategy, and examples : [an honors thesis (HONRS 499)] , 2008 .

[26]  X. Liang,et al.  Investigation of customer satisfaction in student food service: An example of student cafeteria in NHH , 2009 .

[27]  Heesup Han,et al.  The Roles of the Physical Environment, Price Perception, and Customer Satisfaction in Determining Customer Loyalty in the Restaurant Industry , 2009 .

[28]  Giuliano Dall'O' Green Energy Audit of Buildings - A Guide for a Sunstainable Energy Audit of Buildings , 2013 .

[29]  Mohammad A. Hassanain,et al.  A multi‐phase systematic framework for performance appraisal of architectural design studio facilities , 2012 .