Multimodal Imaging and Lighting Bias Correction for Improved μPAD-based Water Quality Monitoring via Smartphones

Smartphone image-based sensing of microfluidic paper analytical devices (μPADs) offers low-cost and mobile evaluation of water quality. However, consistent quantification is a challenge due to variable environmental, paper, and lighting conditions, especially across large multi-target μPADs. Compensations must be made for variations between images to achieve reproducible results without a separate lighting enclosure. We thus developed a simple method using triple-reference point normalization and a fast-Fourier transform (FFT)-based pre-processing scheme to quantify consistent reflected light intensity signals under variable lighting and channel conditions. This technique was evaluated using various light sources, lighting angles, imaging backgrounds, and imaging heights. Further testing evaluated its handle of absorbance, quenching, and relative scattering intensity measurements from assays detecting four water contaminants – Cr(VI), total chlorine, caffeine, and E. coli K12 – at similar wavelengths using the green channel of RGB images. Between assays, this algorithm reduced error from μPAD surface inconsistencies and cross-image lighting gradients. Although the algorithm could not completely remove the anomalies arising from point shadows within channels or some non-uniform background reflections, it still afforded order-of-magnitude quantification and stable assay specificity under these conditions, offering one route toward improving smartphone quantification of μPAD assays for in-field water quality monitoring.

[1]  Hongying Zhu,et al.  Calling Biomarkers in Milk Using a Protein Microarray on Your Smartphone , 2015, PloS one.

[2]  A. Jamalipour,et al.  Lab-in-a-Phone: Smartphone-Based Portable Fluorometer for pH Measurements of Environmental Water , 2014, IEEE Sensors Journal.

[3]  Arjen Ysbert Hoekstra,et al.  Water scarcity challenges to business , 2014 .

[4]  Ming-Chun Huang,et al.  Rapid electrochemical detection on a mobile phone. , 2013, Lab on a chip.

[5]  Brian T. Cunningham,et al.  Smartphone fluorescence spectroscopy , 2014, Photonics West - Biomedical Optics.

[6]  Tu San Park,et al.  Smartphone Detection of Escherichia coli From Field Water Samples on Paper Microfluidics , 2015, IEEE Sensors Journal.

[7]  Alex Nemiroski,et al.  Universal mobile electrochemical detector designed for use in resource-limited applications , 2014, Proceedings of the National Academy of Sciences.

[8]  Fu-Hsiang Ko,et al.  A rapid and portable sensor based on protein-modified gold nanoparticle probes and lateral flow assay for naked eye detection of mercury ion , 2012 .

[9]  Aydogan Ozcan,et al.  Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array. , 2013, Lab on a chip.

[10]  Arben Merkoçi,et al.  High sensitive gold-nanoparticle based lateral flow Immunodevice for Cd2+ detection in drinking waters. , 2013, Biosensors & bioelectronics.

[11]  V. P. Olivieri,et al.  Stability and effectiveness of chlorine disinfectants in water distribution systems. , 1986, Environmental health perspectives.

[12]  Krista G. Hilchey,et al.  A review of citizen science and community-based environmental monitoring: issues and opportunities , 2011, Environmental monitoring and assessment.

[13]  Anatoly V. Zherdev,et al.  Quantum dot-based lateral flow immunoassay for detection of chloramphenicol in milk , 2013, Analytical and Bioanalytical Chemistry.

[14]  Wenyue Li,et al.  Smartphone quantifies Salmonella from paper microfluidics. , 2013, Lab on a chip.

[15]  T. Daim,et al.  Exploring the adoption and use of the smartphone technology in emerging regions: A literature review and hypotheses development , 2015, 2015 Portland International Conference on Management of Engineering and Technology (PICMET).

[16]  Li Jiang,et al.  Smartphone technology can be transformative to the deployment of lab-on-chip diagnostics. , 2014, Lab on a chip.

[17]  Li Shen,et al.  Point-of-care colorimetric detection with a smartphone. , 2012, Lab on a chip.

[18]  Geertruida A. Posthuma-Trumpie,et al.  Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey , 2009, Analytical and bioanalytical chemistry.

[19]  David Erickson,et al.  Cholesterol testing on a smartphone. , 2014, Lab on a chip.

[20]  Lauro T Kubota,et al.  Sensing approaches on paper-based devices: a review , 2013, Analytical and Bioanalytical Chemistry.

[21]  Robert C. Wolpert,et al.  A Review of the , 1985 .

[22]  Ali K. Yetisen,et al.  A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests , 2014 .

[23]  D. Boulware,et al.  Multisite Validation of Cryptococcal Antigen Lateral Flow Assay and Quantification by Laser Thermal Contrast , 2014, Emerging infectious diseases.

[24]  Aydogan Ozcan,et al.  A personalized food allergen testing platform on a cellphone. , 2013, Lab on a chip.

[25]  David J. You,et al.  Cell-phone-based measurement of TSH using Mie scatter optimized lateral flow assays. , 2013, Biosensors & bioelectronics.

[26]  C. Corminboeuf,et al.  Fluorescence sensing of caffeine in water with polysulfonated pyrenes. , 2011, Chemical communications.

[27]  E. Eichten,et al.  Issues and Opportunities in Exotic Hadrons , 2015, 1511.06779.

[28]  Aydogan Ozcan,et al.  Emerging Technologies for Next-Generation Point-of-Care Testing. , 2015, Trends in biotechnology.

[29]  Veronica Leautaud,et al.  A Lateral Flow Assay for Quantitative Detection of Amplified HIV-1 RNA , 2012, PloS one.

[30]  Lin Wang,et al.  Advances in Smartphone-Based Point-of-Care Diagnostics , 2015, Proceedings of the IEEE.