Digital Filters for Fast Harmonic Sequence Component Separation of Unbalanced and Distorted Three-Phase Signals

In this paper, two methods for determining the fundamental frequency and harmonic positive- and negative-sequence components of three-phase signals are investigated. Many aspects of the space-vector discrete Fourier transform and generalized delayed signal cancellation (GDSC) such as response time for different possible implementations, frequency adaptation schemes, stability of recursive implementation, and rounding error effects are discussed. A new design procedure for GDSC transformations is presented. New indices for characterizing three-phase unbalanced and distorted signals are proposed. Simulations and experiments are included in order to verify the performances and illustrate the theoretical conclusions.

[1]  Bin Wu,et al.  Space Vector Sequence Investigation and Synchronization Methods for Active Front-End Rectifiers in High-Power Current-Source Drives , 2008, IEEE Transactions on Industrial Electronics.

[2]  Mario Rizo,et al.  A Generalized Delayed Signal Cancellation Method for Detecting Fundamental-Frequency Positive-Sequence Three-Phase Signals , 2010, IEEE Transactions on Power Delivery.

[3]  S. Srianthumrong,et al.  An active power filter with harmonic detection method based on recursive DFT , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).

[4]  T. Funaki,et al.  Error estimation and correction of DFT in synchronized phasor measurement , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[5]  F. Blaabjerg,et al.  Detection is key - Harmonic detection methods for active power filter applications , 2007, IEEE Industry Applications Magazine.

[6]  G. Saccomando,et al.  Transient operation of grid-connected voltage source converter under unbalanced voltage conditions , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[7]  F. Profumo,et al.  Analysis and Comparison of Phase Locked Loop Techniques for Grid Utility Applications , 2007, 2007 Power Conversion Conference - Nagoya.

[8]  V. Blasko,et al.  Operation of a phase locked loop system under distorted utility conditions , 1997 .

[9]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[10]  E.J. Bueno,et al.  SPLL design to flux oriented of a VSC interface for wind power applications , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[11]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .

[12]  G. Escobar,et al.  Fixed reference frame phase-locked loop (FRF-PLL) for unbalanced line voltage conditions , 2008, 2008 IEEE Power Electronics Specialists Conference.

[13]  M.R. Iravani,et al.  A method for synchronization of power electronic converters in polluted and variable-frequency environments , 2004, IEEE Transactions on Power Systems.

[14]  J. Svensson,et al.  Practical Implementation of Delayed Signal Cancellation Method for Phase-Sequence Separation , 2007, IEEE Transactions on Power Delivery.

[15]  Alan V. Oppenheim,et al.  Discrete-Time Signal Pro-cessing , 1989 .

[16]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[17]  F.P. Marafao,et al.  Frequency-Adjustable Positive Sequence Detector for Power Conditioning Applications , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[18]  M. Liserre,et al.  Synchronization methods for three phase distributed power generation systems - An overview and evaluation , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[19]  S.M. Silva,et al.  PLL structures for utility connected systems , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[20]  Francisco A. S. Neves,et al.  A Method for Extracting the Fundamental-Frequency Positive-Sequence Voltage Vector Based on Simple Mathematical Transformations , 2008, IEEE Transactions on Industrial Electronics.

[21]  H.A. Darwish,et al.  Practical Considerations for Recursive DFT Implementation in Numerical Relays , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.

[22]  K. Borisov,et al.  A novel reference signal generator for active power filters based on Recursive DFT , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.

[23]  M. Liserre,et al.  A Comparative Analysis of Real-Time Algorithms for Power Signal Decomposition in Multiple Synchronous Reference Frames , 2007, IEEE Transactions on Power Electronics.

[24]  Zhe Chen,et al.  Multiple-Complex Coefficient-Filter-Based Phase-Locked Loop and Synchronization Technique for Three-Phase Grid-Interfaced Converters in Distributed Utility Networks , 2011, IEEE Transactions on Industrial Electronics.

[25]  Francisco A S Neves,et al.  Low effort digital filters for fast sequence components separation of unbalanced and distorted three-phase signals , 2010, 2010 IEEE International Symposium on Industrial Electronics.

[26]  Francisco A. S. Neves,et al.  A Space-Vector Discrete Fourier Transform for Unbalanced and Distorted Three-Phase Signals , 2010, IEEE Transactions on Industrial Electronics.

[27]  Pablo Fernandez-Comesana,et al.  A Signal-Processing Adaptive Algorithm for Selective Current Harmonic Cancellation in Active Power Filters , 2009, IEEE Transactions on Industrial Electronics.

[28]  M. Karimi-Ghartemani,et al.  Processing of Symmetrical Components in Time-Domain , 2007, IEEE Transactions on Power Systems.

[29]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .