Multi-line transmission in 3-D with reduced crosstalk artifacts: a proof of concept study

Multi-line transmission (MLT) is a technique in which ultrasound pulses for several directions are transmitted simultaneously. The purpose is increased frame rate, which is especially important in 3-D echocardiography. Compared with techniques purely based on parallel beamformation, MLT avoids the need for reducing the transmit aperture and thus maintains a high harmonic signal level. The main disadvantage is that artifacts are caused by cross-talk between the simultaneous beams. In a conventional MLT implementation, simultaneous transmits would be spaced regularly in the azimuth and elevation planes. However, using rectangular geometry arrays, most of the acoustic side-lobe energy is concentrated along these planes. The results in this work show that the crosstalks can be pushed below the typical display range of 50 dB used in cardiac applications if the parallel transmit directions are aligned along the transverse diagonal of the array. Dispositions with 2 to 5 MLT for a typical cardiac 2-D phased-array were investigated using simulation software. Using the proposed alignment, the maximal crosstalk artifact amplitudes decreased 20 to 30 dB compared with conventional MLT dispositions. In water-tank measurements, side-lobe levels of a commercially available rectangular probe were 15 to 25 dB lower along the transverse diagonal, confirming that similar suppressions can be expected using actual transducers.

[1]  Svein Brekke,et al.  Volume stitching in three-dimensional echocardiography: distortion analysis and extension to real time. , 2007, Ultrasound in medicine & biology.

[2]  O. Basset,et al.  Fast and accurate nonlinear pressure field simulation: A finite-difference scheme into the Fourier domain , 2012, 2012 IEEE International Ultrasonics Symposium.

[3]  O T von Ramm,et al.  Explososcan: A Parallel Processing Technique For High Speed Ultrasound Imaging With Linear Phased Arrays , 1985, Medical Imaging.

[4]  M. Fink,et al.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Raoul Mallart,et al.  Improved imaging rate through simultaneous transmission of several ultrasound beams , 1992, SPIE Optics + Photonics.

[6]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[7]  Sverre Holm,et al.  Fast simulation of second harmonic ultrasound field using a quasi-linear method. , 2012, The Journal of the Acoustical Society of America.

[8]  M. Fink,et al.  Ultrafast imaging of the heart using circular wave synthetic imaging with phased arrays , 2009, 2009 IEEE International Ultrasonics Symposium.

[9]  Hiroshi Kanai,et al.  Ultrasonic Imaging of Propagation of Contraction and Relaxation in the Heart Walls at High Temporal Resolution , 2007 .

[10]  M O'Donnell,et al.  Retrospective dynamic transmit focusing. , 1995, Ultrasonic imaging.

[11]  K. Thomenius,et al.  Accelerated focused ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Hiroshi Kanai,et al.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming , 2011, Journal of Medical Ultrasonics.

[13]  M. Frijlink,et al.  Abersim: A simulation program for 3D nonlinear acoustic wave propagation for arbitrary pulses and arbitrary transducer geometries , 2008, 2008 IEEE Ultrasonics Symposium.

[14]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[16]  A. Drukarev,et al.  Beam transformation techinques for ultrasonic medical imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Roberto M. Lang,et al.  Textbook of real-time three-dimensional echocardiography , 2011 .

[18]  L. Demi,et al.  Parallel transmit beamforming using orthogonal frequency division multiplexing applied to harmonic Imaging-A feasibility study , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  F. Duck Nonlinear acoustics in diagnostic ultrasound. , 2002, Ultrasound in medicine & biology.

[20]  P. Wells,et al.  Ultrasound imaging , 2006, Physics in medicine and biology.

[21]  Hang Gao,et al.  Multi-transmit beam forming for fast cardiac imaging , 2011 .

[22]  Bastien Denarie,et al.  Coherent Plane Wave Compounding for Very High Frame Rate Ultrasonography of Rapidly Moving Targets , 2013, IEEE Transactions on Medical Imaging.