Comparison of femoral sagittal axis between navigated total knee arthroplasty and conventional total knee arthroplasty in patients with knee osteoarthritis

To compare femoral sagittal axis between navigated total knee arthroplasty (TKA) and conventional TKA. A total of 136 cases were assigned to group 1 (navigated TKA) and 77 cases were assigned to group 2 (conventional TKA). Specifically, this study targeted patients with degenerative osteoarthritis. Only patients with primary TKA were analyzed. Hip knee ankle angle and lateral femoral bowing were measured using preoperative scanogram. Anterior femoral bowing was measured using preoperative femoral lateral X rays. The presence of anterior femoral notching and the insertion angle of the femoral implant with respect to the anatomical sagittal plane of the distal femur were checked using postoperative lateral knee X rays. Student t-test was used to compare the difference in the position of the sagittal plane of the femoral implant between the navigated TKA group and the conventional TKA group. When comparing the 2 groups, the sagittal axis of the femoral implant was more extended than the anatomical sagittal plane axis of the distal femur in group 1 than in group 2 (P = .01). There was a significant negative correlation between the value of anterior femoral bowing and the degree of flexion to the sagittal plane of the femoral implant in group 1 (correlation coefficient: –0.40, P = .01). The occurrence of anterior femoral notching was significantly higher in group 1 than in group 2. During navigated TKA, imageless navigation does not consider the anatomical variation of the femoral shaft. Therefore, surgeons should take into consideration that when performing navigated TKA, a femoral implant could be inserted more extended for the anatomical sagittal axis of the distal femur than for the conventional TKA. Also, surgeon should know that the degree of extension insertion of the femoral implant increases as femoral anterior bowing increases.

[1]  R. Kanna,et al.  Notching is less, if femoral component sagittal positioning is planned perpendicular to distal femur anterior cortex axis, in navigated TKA , 2021, Knee Surgery & Related Research.

[2]  Ng Jonathan Patrick,et al.  No difference in long-term functional outcomes or survivorship after total knee arthroplasty with or without computer navigation: a 17-year survivorship analysis , 2021, Knee Surgery & Related Research.

[3]  Takashi Sato,et al.  Comparison of post-operative three-dimensional and two-dimensional evaluation of component position for total knee arthroplasty , 2021, Knee Surgery & Related Research.

[4]  S. Song,et al.  Appropriateness of the Use of Navigation System in Total Knee Arthroplasty , 2020, Clinics in orthopedic surgery.

[5]  J. Nho,et al.  Reliability of measuring lateral bowing angle of the femur in patients with atypical femur fractures , 2019, Journal of orthopaedic surgery.

[6]  Yuefu Dong,et al.  Optimization of parameters for femoral component implantation during TKA using finite element analysis and orthogonal array testing , 2018, Journal of Orthopaedic Surgery and Research.

[7]  W. Choi,et al.  Relationship between Lateral Femoral Bowing and Varus Knee Deformity Based on Two-Dimensional Assessment of Side-to-Side Differences , 2018, Knee surgery & related research.

[8]  D. Shi,et al.  The assessment of femoral shaft morphology in the sagittal plane in Chinese patients with osteoarthritis—a radiographic analysis , 2017, Journal of Orthopaedic Surgery and Research.

[9]  N. Yamamoto,et al.  Radiological assessment of the femoral bowing in Japanese population , 2016, SICOT-J.

[10]  Ju Hong Lee,et al.  Risk of Anterior Femoral Notching in Navigated Total Knee Arthroplasty , 2015, Clinics in orthopedic surgery.

[11]  Y. Minoda,et al.  Theoretical risk of anterior femoral cortex notching in total knee arthroplasty using a navigation system. , 2013, The Journal of arthroplasty.

[12]  K. Takaoka,et al.  The risk of notching the anterior femoral cortex with the use of navigation systems in total knee arthroplasty , 2010, Knee Surgery, Sports Traumatology, Arthroscopy.

[13]  K. Takaoka,et al.  TKA Sagittal Alignment with Navigation Systems and Conventional Techniques Vary Only a Few Degrees , 2009, Clinical orthopaedics and related research.

[14]  C. Chang,et al.  Differences between Sagittal Femoral Mechanical and Distal Reference Axes Should Be Considered in Navigated TKA , 2009, Clinical orthopaedics and related research.

[15]  Y.H. Kim,et al.  Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. , 2007, The Journal of bone and joint surgery. British volume.

[16]  W. Yau,et al.  Coronal Bowing of the Femur and Tibia in Chinese: Its Incidence and Effects on Total Knee Arthroplasty Planning , 2007, Journal of orthopaedic surgery.

[17]  S David Stulberg,et al.  How accurate is current TKR instrumentation? , 2003, Clinical orthopaedics and related research.