Synchronized dynamic dose reconstruction.

Variations in target volume position between and during treatment fractions can lead to measurable differences in the dose distribution delivered to each patient. Current methods to estimate the ongoing cumulative delivered dose distribution make idealized assumptions about individual patient motion based on average motions observed in a population of patients. In the delivery of intensity modulated radiation therapy (IMRT) with a multi-leaf collimator (MLC), errors are introduced in both the implementation and delivery processes. In addition, target motion and MLC motion can lead to dosimetric errors from interplay effects. All of these effects may be of clinical importance. Here we present a method to compute delivered dose distributions for each treatment beam and fraction, which explicitly incorporates synchronized real-time patient motion data and real-time fluence and machine configuration data. This synchronized dynamic dose reconstruction method properly accounts for the two primary classes of errors that arise from delivering IMRT with an MLC: (a) Interplay errors between target volume motion and MLC motion, and (b) Implementation errors, such as dropped segments, dose over/under shoot, faulty leaf motors, tongue-and-groove effect, rounded leaf ends, and communications delays. These reconstructed dose fractions can then be combined to produce high-quality determinations of the dose distribution actually received to date, from which individualized adaptive treatment strategies can be determined.

[1]  Ping Xia,et al.  Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system. , 2002, Medical physics.

[2]  A L Boyer,et al.  Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system. , 1997, Medical physics.

[3]  I. Chetty,et al.  Accounting for center-of-mass target motion using convolution methods in Monte Carlo-based dose calculations of the lung. , 2004, Medical physics.

[4]  T. Solberg,et al.  A virtual source model for Monte Carlo modeling of arbitrary intensity distributions. , 2000, Medical physics.

[5]  Steve B. Jiang,et al.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. , 2002, Physics in medicine and biology.

[6]  J. Dai,et al.  Simultaneous minimization of leaf travel distance and tongue-and-groove effect for segmental intensity-modulated radiation therapy , 2004, Physics in medicine and biology.

[7]  Sartaj Sahni,et al.  Algorithms for optimal sequencing of dynamic multileaf collimators. , 2004, Physics in medicine and biology.

[8]  K. Lam,et al.  Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. , 1998, International journal of radiation oncology, biology, physics.

[9]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[10]  S. Sahni,et al.  Optimal leaf sequencing with elimination of tongue-and-groove underdosage. , 2004, Physics in medicine and biology.

[11]  James F Dempsey,et al.  Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device. , 2004, Medical physics.

[12]  Jean M. Moran,et al.  Verification of dynamic and segmental IMRT delivery by dynamic log file analysis , 2002, Journal of applied clinical medical physics.

[13]  A L Boyer,et al.  An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators , 1998, Physics in medicine and biology.

[14]  Jean M. Moran,et al.  Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculation. , 2007 .

[15]  J. Dempsey,et al.  An extensive log-file analysis of step-and-shoot intensity modulated radiation therapy segment delivery errors. , 2004, Medical physics.

[16]  J. Wong,et al.  Estimating the dose variation in a volume of interest with explicit consideration of patient geometric variation. , 2000, Medical physics.

[17]  J. V. van Santvoort,et al.  Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profiles. , 1998, Physics in Medicine and Biology.

[18]  J. V. van Santvoort,et al.  Dynamic multileaf collimation without 'tongue-and-groove' underdosage effects. , 1996, Physics in medicine and biology.

[19]  S. Webb Motion effects in (intensity modulated) radiation therapy: a review , 2006, Physics in medicine and biology.

[20]  M. Langer,et al.  Improved leaf sequencing reduces segments or monitor units needed to deliver IMRT using multileaf collimators. , 2001, Medical physics.

[21]  J. Sempau,et al.  DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations , 2000 .

[22]  Randall K Ten Haken,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: sensitivity to variations in motion. , 2003, Medical physics.

[23]  K M Ayyangar,et al.  Leaf sequencing techniques for MLC-based IMRT. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[24]  Michael Unser,et al.  A pyramid approach to subpixel registration based on intensity , 1998, IEEE Trans. Image Process..

[25]  T LoSasso,et al.  Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. , 2001, Medical physics.

[26]  Jonathan G. Li,et al.  Inverse planning incorporating organ motion. , 2000 .

[27]  Paul Keall,et al.  Real-time DMLC IMRT delivery for mobile and deforming targets. , 2005, Medical physics.

[28]  Indrin J Chetty,et al.  Photon beam relative dose validation of the DPM Monte Carlo code in lung-equivalent media. , 2003, Medical physics.

[29]  Linda Hong,et al.  The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator. , 2003, Medical physics.

[30]  J Dai,et al.  'Tongue-and-groove' effect in intensity modulated radiotherapy with static multileaf collimator fields. , 2004, Physics in medicine and biology.

[31]  Gary A. Ezzell,et al.  The overshoot phenomenon in step‐and‐shoot IMRT delivery , 2001, Journal of applied clinical medical physics.

[32]  James M. Balter,et al.  A precision translation stage for reproducing measured target volume motions , 2007, Journal of applied clinical medical physics.

[33]  P J Keall,et al.  The application of the sinusoidal model to lung cancer patient respiratory motion. , 2005, Medical physics.

[34]  James F Dempsey,et al.  Validation of dynamic MLC-controller log files using a two-dimensional diode array. , 2003, Medical physics.

[35]  Lei Xing,et al.  Incorporating leaf transmission and head scatter corrections into step-and-shoot leaf sequences for IMRT. , 2003, International journal of radiation oncology, biology, physics.

[36]  J. Battista,et al.  A convolution method of calculating dose for 15-MV x rays. , 1985, Medical physics.

[37]  L Xing,et al.  Minimizing delivery time and monitor units in static IMRT by leaf-sequencing. , 2002, Physics in medicine and biology.

[38]  S. Sahni,et al.  A comparison of step-and-shoot leaf sequencing algorithms that eliminate tongue-and-groove effects. , 2004, Physics in medicine and biology.

[39]  R Mohan,et al.  Monte Carlo as a four-dimensional radiotherapy treatment-planning tool to account for respiratory motion. , 2004, Physics in medicine and biology.

[40]  P. Xia,et al.  Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments. , 1998, Medical physics.

[41]  Zuofeng Li,et al.  Monte Carlo calculations of dosimetry parameters of the urocor prostaseed 125I source. , 2002, Medical physics.

[42]  Matthias Fippel,et al.  Study on the Tongue and Groove Effect of the Elekta Multileaf Collimator Using Monte Carlo Simulation and Film Dosimetry , 2004, Strahlentherapie und Onkologie.

[43]  Indrin J Chetty,et al.  A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: a Monte Carlo study. , 2003, Medical physics.

[44]  Benedick A Fraass,et al.  Incorporation of realistic delivery limitations into dynamic MLC treatment delivery. , 2002, Medical physics.

[45]  Steve B. Jiang,et al.  Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number. , 2003, Medical physics.

[46]  Warren D D'Souza,et al.  A stochastic convolution/superposition method with isocenter sampling to evaluate intrafraction motion effects in IMRT. , 2005, Medical physics.

[47]  John Wong,et al.  Accuracy of a wireless localization system for radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[48]  G S Bauman,et al.  Validation of contour-driven thin-plate splines for tracking fraction-to-fraction changes in anatomy and radiation therapy dose mapping , 2005, Physics in medicine and biology.

[49]  C. Ling,et al.  Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate. , 1997, International journal of radiation oncology, biology, physics.

[50]  S Webb,et al.  The effect on IMRT conformality of elastic tissue movement and a practical suggestion for movement compensation via the modified dynamic multileaf collimator (dMLC) technique , 2005, Physics in medicine and biology.

[51]  D A Jaffray,et al.  The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. , 1998, Physics in medicine and biology.

[52]  Steve B. Jiang,et al.  An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments. , 2003, Physics in medicine and biology.

[53]  T. Bortfeld,et al.  X-ray field compensation with multileaf collimators. , 1994, International journal of radiation oncology, biology, physics.

[54]  J C Rosenwald,et al.  Conformal radiotherapy (CRT) planning for lung cancer: analysis of intrathoracic organ motion during extreme phases of breathing. , 2001, International journal of radiation oncology, biology, physics.

[55]  Patrick A Kupelian,et al.  Influence of intrafraction motion on margins for prostate radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[56]  Indrin J Chetty,et al.  Benchmarking of the dose planning method (DPM) Monte Carlo code using electron beams from a racetrack microtron. , 2002, Medical physics.