Regional brain glucose metabolism in patients with complex partial seizures investigated by intracranial EEG

We performed interictal 18F-2-fluoro-2-deoxy-D-glucose positron emission tomography (18FDG-PET) studies in 57 patients with complex partial epilepsy (CPE), not controlled by medical treatment and considered for surgical resection of their epileptic focus. A precise localization of the epileptic focus was obtained in 37 of these patients with a combination of subdural and depth electrodes. We visually inspected the metabolic images; we also measured glucose consumption in a number of brain regions and compared the values with those obtained in 17 normal controls. Eighty-two percent of the 57 patients had an area of glucose hypometabolism on the 18FDG-PET images. Six patients had a frontal epileptic focus, 3 of them had a frontal lobe hypometabolism. Twenty-six patients had a unilateral temporal lobe focus and all of them displayed a temporal lobe hypometabolism. The asymmetry was more pronounced in the lateral temporal cortex (-20%) than in the mesial part of the temporal lobe (-9.6%). In each cortical brain region on the side of the epileptic focus (except the sensorimotor cortex), glucose consumption rate was lower than in the contralateral region or than in controls. No differences could be found between patients with a seizure onset restricted to the hippocampus and patients with a seizure onset involving the hippocampus and the adjacent neocortex. Divergent metabolic patterns were obtained in 5 patients with bilateral temporal seizure foci. Combined with other non invasive techniques (EEG, neuroradiology), PET contributes increasingly to the selection of patients with CPE who could benefit from surgical treatment.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  M E Phelps,et al.  Epileptic patterns of local cerebral metabolism and perfusion in humans determined by emission computed tomography of 18FDG and 13NH3 , 1980, Annals of neurology.

[2]  W. Theodore,et al.  Patterns of cerebral glucose metabolism in patients with partial seizures , 1988, Neurology.

[3]  Michael E. Phelps,et al.  Comparative localization of foci in partial epilepsy by PCT and EEG , 1982 .

[4]  G. Sedvall,et al.  IN-VIVO DEMONSTRATION OF REDUCED BENZODIAZEPINE RECEPTOR BINDING IN HUMAN EPILEPTIC FOCI , 1988, The Lancet.

[5]  L F Quesney,et al.  False lateralization by surface EEG of seizure onset in patients with temporal lobe epilepsy and gross focal cerebral lesions , 1987, Annals of neurology.

[6]  J C Mazziotta,et al.  Quantitation in Positron Emission Computed Tomography: 5. Physical–Anatomical Effects , 1981, Journal of computer assisted tomography.

[7]  Sid Gilman,et al.  Positron emission tomography studies of cerebral glucose metabolism in chronic partial epilepsy , 1987, Annals of neurology.

[8]  E. Hoffman,et al.  Tomographic measurement of local cerebral glucose metabolic rate in humans with (F‐18)2‐fluoro‐2‐deoxy‐D‐glucose: Validation of method , 1979, Annals of neurology.

[9]  W. J. Brown,et al.  Pathological findings underlying focal temporal lobe hypometabolism in partial epilepsy , 1982, Annals of neurology.

[10]  Alan A. Wilson,et al.  Mu‐opiate receptors measured by positron emission tomography are increased in temporal lobe epilepsy , 1988, Annals of neurology.

[11]  J. Mazziotta,et al.  Presurgical evaluation for partial epilepsy , 1990, Neurology.

[12]  J C Depresseux,et al.  Regional cerebral blood flow and metabolic rates in human focal epilepsy and status epilepticus. , 1986, Advances in neurology.

[13]  P. Maquet,et al.  Epilepsy: The Use of Oxygen-15-Labeled Gases , 1989, Seminars in neurology.

[14]  Alan A. Wilson,et al.  Quantification of mu and non–mu opiate receptors in temporal lobe epilepsy using positron emission tomography , 1991, Annals of neurology.

[15]  W H Theodore,et al.  Antiepileptic Drugs and Cerebral Glucose Metabolism , 1988, Epilepsia.

[16]  K. Lindahl-Kiessling,et al.  USE AND ABUSE OF ELECTROENCEPHALOGRAPHY. , 1964, Lancet.

[17]  D. Spencer,et al.  Reliability and accuracy of localization by scalp ictal EEG , 1985, Neurology.

[18]  L F Quesney,et al.  Depth electrode investigations in patients with bitemporal epileptiform abnormalities , 1989, Annals of neurology.

[19]  C. V. van Veelen,et al.  Presurgical evaluation of patients with intractable partial epilepsy: the Dutch epilepsy surgery program. , 1991, Acta neurologica Belgica.

[20]  Michael Channing,et al.  {18F}fluorodeoxyglucose positron emission tomography in refractory complex partial seizures , 1983, Annals of neurology.

[21]  Demetrios N. Velis,et al.  Combined use of subdural and intracerebral electrodes in preoperative evaluation of epilepsy. , 1990 .

[22]  S Gilman,et al.  Differences between lateral and mesial temporal metabolism interictally in epilepsy of mesial temporal origin , 1990, Neurology.

[23]  Michael E. Phelps,et al.  Quantitation in Positron Emission Computed Tomography , 1980 .

[24]  Functional localization of epileptogenic lesions , 1983, Trends in Neurosciences.