Detection of Inter-Turn Faults in Multi-Phase Ferrite-PM Assisted Synchronous Reluctance Machines

Inter-turn winding faults in five-phase ferrite-permanent magnet-assisted synchronous reluctance motors (fPMa-SynRMs) can lead to catastrophic consequences if not detected in a timely manner, since they can quickly progress into more severe short-circuit faults, such as coil-to-coil, phase-to-ground or phase-to-phase faults. This paper analyzes the feasibility of detecting such harmful faults in their early stage, with only one short-circuited turn, since there is a lack of works related to this topic in multi-phase fPMa-SynRMs. Two methods are tested for this purpose, the analysis of the spectral content of the zero-sequence voltage component (ZSVC) and the analysis of the stator current spectra, also known as motor current signature analysis (MCSA), which is a well-known fault diagnosis method. This paper compares the performance and sensitivity of both methods under different operating conditions. It is proven that inter-turn faults can be detected in the early stage, with the ZSVC providing more sensitivity than the MCSA method. It is also proven that the working conditions have little effect on the sensitivity of both methods. To conclude, this paper proposes two inter-turn fault indicators and the threshold values to detect such faults in the early stage, which are calculated from the spectral information of the ZSVC and the line currents.

[1]  Eva Cosoroaba,et al.  Thermal signature analysis of an 8/6 switched reluctance motor under inter-turn short circuit fault , 2018, 2018 IEEE International Conference on Industrial Technology (ICIT).

[2]  Oskar Wallmark,et al.  Control algorithms for a fault-tolerant PMSM drive , 2007, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[3]  Wenxin Huang,et al.  Analysis of a Dual-Winding Fault-Tolerant Permanent Magnet Machine Drive for Aerospace Applications , 2015, IEEE Transactions on Magnetics.

[4]  Thomas A. Lipo,et al.  Performance Improvement of Ferrite-Assisted Synchronous Reluctance Machines Using Asymmetrical Rotor Configurations , 2015, IEEE Transactions on Magnetics.

[5]  L. Romeral,et al.  A Back-emf Based Method to Detect Magnet Failures in PMSMs , 2013, IEEE Transactions on Magnetics.

[6]  Jin Hur,et al.  Early Detection Technique for Stator Winding Inter-Turn Fault in BLDC Motor Using Input Impedance , 2015, IEEE Transactions on Industry Applications.

[7]  Jordi-Roger Riba,et al.  Rare-earth-free propulsion motors for electric vehicles: A technology review , 2016 .

[8]  Yu-Min Hsueh,et al.  Induction Motors Condition Monitoring System with Fault Diagnosis Using a Hybrid Approach , 2019, Energies.

[9]  Seungdeog Choi,et al.  Detection and Estimation of Extremely Small Fault Signature by Utilizing Multiple Current Sensor Signals in Electric Machines , 2017, IEEE Transactions on Industry Applications.

[10]  Mehmet Akar Detection of a static eccentricity fault in a closed loop driven induction motor by using the angular domain order tracking analysis method , 2013 .

[11]  Sai Sudheer Reddy Bonthu,et al.  Comparisons of three-phase and five-phase permanent magnet assisted synchronous reluctance motors , 2016 .

[12]  Sang Woo Kim,et al.  Diagnosis of Interturn Short-Circuit Fault in PMSM by Residual Voltage Analysis , 2018, 2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM).

[13]  S. Nandi,et al.  Analysis, modeling and simulation of static eccentric reluctance synchronous motor , 2011, 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives.

[14]  Jordi-Roger Riba,et al.  Detection of Inter-turn Faults in Five-Phase Permanent Magnet Synchronous Motors , 2014 .

[15]  Jordi-Roger Riba,et al.  Influence of the Stator Windings Configuration in the Currents and Zero-Sequence Voltage Harmonics in Permanent Magnet Synchronous Motors With Demagnetization Faults , 2013, IEEE Transactions on Magnetics.

[16]  Li Quan,et al.  Design and Multi-Objective Stratified Optimization of a Less-Rare-Earth Hybrid Permanent Magnets Motor With High Torque Density and Low Cost , 2019, IEEE Transactions on Energy Conversion.

[17]  Andrew Ball,et al.  A Performance Evaluation of Two Bispectrum Analysis Methods Applied to Electrical Current Signals for Monitoring Induction Motor-Driven Systems , 2019 .

[18]  Mohammad Ali Abido,et al.  An efficient stator inter-Turn fault diagnosis tool for induction motors , 2018 .

[19]  Jawad Faiz,et al.  Interturn fault diagnosis in brushless direct current motors — A review , 2018, 2018 IEEE International Conference on Industrial Technology (ICIT).

[20]  Jordi-Roger Riba,et al.  Mixed resistive unbalance and winding inter-turn faults model of permanent magnet synchronous motors , 2015 .

[21]  Jordi-Roger Riba,et al.  Detection of interturn faults in PMSMs with different winding configurations , 2014 .

[22]  Nicola Bianchi,et al.  Fast synthesis of permanent magnet assisted synchronous reluctance motors , 2016 .

[23]  Jordi-Roger Riba,et al.  Detection of Eccentricity Faults in Five-Phase Ferrite-PM Assisted Synchronous Reluctance Machines , 2017 .

[24]  Yucai Wu,et al.  Anti-Interference and Location Performance for Turn-to-Turn Short Circuit Detection in Turbo-Generator Rotor Windings , 2019 .

[25]  Gianluca Ippoliti,et al.  Electric Motor Fault Detection and Diagnosis by Kernel Density Estimation and Kullback–Leibler Divergence Based on Stator Current Measurements , 2015, IEEE Transactions on Industrial Electronics.

[26]  Tae-Sik Kong,et al.  Identification of False Rotor Fault Indications Produced by Online MCSA for Medium-Voltage Induction Machines , 2016, IEEE Transactions on Industry Applications.

[27]  Raphaël Romary,et al.  Offline and Online Methods for Stator Core Fault Detection in Large Generators , 2013, IEEE Transactions on Industrial Electronics.

[28]  Adel Belouchrani,et al.  Fault Diagnosis in Industrial Induction Machines Through Discrete Wavelet Transform , 2011, IEEE Transactions on Industrial Electronics.

[29]  Jordi-Roger Riba,et al.  Application of the zero-sequence voltage component to detect stator winding inter-turn faults in PMSMs , 2012 .

[30]  Evgeniy Solodkiy,et al.  Detection Of Stator Inter-turn Short Circuit In Three-Phase Induction Motor Using Current Coordinate Transformation , 2019, 2019 26th International Workshop on Electric Drives: Improvement in Efficiency of Electric Drives (IWED).

[31]  James D. Widmer,et al.  Production and Application of HPMS Recycled Bonded Permanent Magnets for a Traction Motor Application , 2018, IEEE Transactions on Industrial Electronics.

[32]  Sai Sudheer Reddy Bonthu,et al.  Design of five-phase permanent magnet assisted synchronous reluctance motor for low output torque ripple applications , 2016 .

[33]  Nicola Bianchi,et al.  Eccentricity in Synchronous Reluctance Motors—Part I: Analytical and Finite-Element Models , 2015, IEEE Transactions on Energy Conversion.

[34]  Jin Hur,et al.  Detection technique for stator inter-turn faults in BLDC motors based on third harmonic components of line currents , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[35]  T.A. Lipo,et al.  Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations , 2003, IEEE Transactions on Power Electronics.

[36]  A K Wadhwani,et al.  Early Estimation of Faults in Induction Motors Using Symbolic Dynamic-Based Analysis of Stator Current Samples , 2011, IEEE Transactions on Energy Conversion.