Dynamic integrated method based on regression and averages, applied to estimate the thermal parameters of a room in an occupied office building in Madrid

Abstract A room facing north in a fully monitored office building located in Madrid (Spain) has been studied. Data corresponding to a period of more than two years, recorded while the building was regularly used, have been employed. A regression analysis method based on averages has been applied. Although the used equation is analogous to the steady state, dynamic features of the test have been considered. A dynamic energy balance equation is first stated. Then this equation is integrated for a time interval long enough to make the accumulation term much lower than the other terms. Finally averages are used to estimate integrals. The minimum integration period that allows this simplification has been identified, studying integration periods from 1 to 20 days. It is concluded that integration period and variables needed depend on test conditions and the building. Daily averages are insufficient for this analysis in these test conditions. Heat supplied by the HVAC system was modelled avoiding flow measurements. Suggested terms including occupancy and door status improve the model remarkably. A spread in the Overall Heat Transmission Coefficient (UA) estimated under 10%, was found for a 7-day integration period. This narrow interval allows to hand this parameter as intrinsic.

[1]  M. J. Jiménez,et al.  Analysis of capabilities and limitations of the regression method based in averages, applied to the estimation of the U value of building component tested in Mediterranean weather , 2012 .

[2]  J. J Bloem,et al.  A Pseudo Dynamic Analysis Tool for Thermal Certification of Dwellings. , 2001 .

[3]  Ari Rabl Parameter estimation in buildings: Methods for dynamic analysis of measured energy use , 1988 .

[4]  Henrik Madsen,et al.  Estimation of continuous-time models for the heat dynamics of a building , 1995 .

[5]  P. H. Baker,et al.  Outdoor testing, analysis and modelling of building components , 2008 .

[6]  H.A.L. van Dijk,et al.  The PASSYS method for testing passive solar components , 1993 .

[7]  Peder Bacher,et al.  Setting up and validating a complex model for a simple homogeneous wall , 2014 .

[8]  M. J. Jiménez,et al.  Estimation of building component UA and gA from outdoor tests in warm and moderate weather conditions , 2008 .

[9]  S. Soutullo,et al.  Thermal comfort evaluation in a mechanically ventilated office building located in a continental climate , 2014 .

[10]  M. Modera,et al.  Determining the U -Value of a Wall from Field Measurements of Heat Flux and Surface Temperatures , 1985 .

[11]  J. J. Bloem,et al.  HELP (house energy labeling procedure): methodology and present results , 2001 .

[12]  Henrik Madsen,et al.  Models for describing the thermal characteristics of building components , 2008 .

[13]  David Johnston,et al.  Whole House Heat Loss Test Method (Coheating) , 2012 .

[14]  Henrik Madsen,et al.  Estimation of non-linear continuous time models for the heat exchange dynamics of building integrated photovoltaic modules , 2008 .

[15]  Paul Strachan,et al.  Case studies of outdoor testing and analysis of building components , 2008 .