User interface for situational awareness of openPDC

This paper uses complex phasor data (voltage, current and phase angle) from openPDC for situational awareness of the SmartGrid. Alarm notification features through E-mail and Short message service (SMS) on various parameters of Phasor Measurement Units (PMU) data has been developed in C# programming as an extension to the existing openPDC software functionalities. In addition, realtime display of PMU data based on the geographical locations of PMU is developed for openPDC software and is presented within a Google Maps-based Windows Forms application. The paper also discusses how to process the PMU data using a k-means clustering algorithm.

[1]  J. A. Hartigan,et al.  A k-means clustering algorithm , 1979 .

[2]  Greg Zweigle,et al.  Solar generation control with time-synchronized phasors , 2011, 2011 64th Annual Conference for Protective Relay Engineers.

[3]  George Nagy,et al.  State of the art in pattern recognition , 1968 .

[4]  Seema Singh,et al.  Applications of phasor measurement units (PMUs) in electric power system networks incorporated with FACTS controllers , 2011 .

[5]  E.O. Schweitzer,et al.  Real-Time Power System Control Using Synchrophasors , 2008, 2008 61st Annual Conference for Protective Relay Engineers.

[6]  A.G. Phadke,et al.  Synchronized phasor measurements in power systems , 1993, IEEE Computer Applications in Power.

[7]  Arun G. Phadke,et al.  Synchronized Phasor Measurements and Their Applications , 2008 .

[8]  Corinna Cortes,et al.  Support-Vector Networks , 1995, Machine Learning.

[9]  M. Salim Beg,et al.  Vulnerability Analysis of Wide Area Measurement System in the Smart Grid , 2013 .

[10]  R. Moxley,et al.  Generator Black Start Validation Using Synchronized Phasor Measurement , 2006, 2006 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources.

[11]  Yi Hu,et al.  Use of synchrophasor measurements in protective relaying applications , 2014, 2014 67th Annual Conference for Protective Relay Engineers.

[12]  L. Vanfretti,et al.  A fundamental study on damping control design using PMU signals from dominant inter-area oscillation paths , 2012, 2012 North American Power Symposium (NAPS).

[13]  Brian K. Johnson Validation of Transmission Line Relay Parameters Using Synchrophasors , 2015 .

[14]  Bradley Kerwin Greene Novel Applications for Phasor Measurement Units and Synchrophasor Data , 2013 .

[15]  Amjad Ullah,et al.  Advancement in Wide Area Monitoring Protection and Control Using PMU’s Model in MATLAB/SIMULINK , 2012 .

[16]  Noga Alon,et al.  The space complexity of approximating the frequency moments , 1996, STOC '96.